Development of an MR-Compatible High-Definition Flexible Endoscope for Real-Time MR Image-Guided Microwave Ablation

被引:0
|
作者
Yamada, Atsushi [1 ]
Naka, Shigeyuki [2 ,3 ]
Khiem Tran Dang [1 ]
Morikawa, Shigehiro [4 ]
Tani, Tohru [1 ]
机构
[1] Shiga Univ Med Sci, Dept Res & Dev Innovat Med Devices & Syst, Otsu, Shiga 5202192, Japan
[2] Shiga Univ Med Sci, Dept Surg, Otsu, Shiga, Japan
[3] Hino Mem Hosp, Dept Surg, Hino, Tokyo 5291642, Japan
[4] Shiga Univ Med Sci, Mol Neurosci Res Ctr, Otsu, Shiga, Japan
关键词
Magnetic resonance compatibility; Flexible endoscope; Navigation system; COAGULATION THERAPY; THERMOCOAGULATION;
D O I
10.1007/978-981-13-5859-3_4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study aims to develop a magnetic resonance (MR)-compatible flexible endoscope for minimally invasive real-time MR image-guided microwave ablation as proposed by the author with a widely available 3-Tesla close-bore MR scanner and to assess the feasibility of including a position tracking sensor. A unique MR-compatible high-definition (HD) endoscope was developed to access a target organ from outside the scanner bore by obtaining endoscope optical camera and scan images simultaneously. The camera unit consists of a CMOS image sensor with 400 x 400 pixels. The camera head and the lens barrel are made of phosphor bronze and a Pebax elastomer sheath with a 2.1 mm diameter shielded by tin-plated copper wires. The image resolution was up-converted to 700 x 700 pixels using a high-resolution image processing technique. The endoscope had two working channels (2.0 mm in each outer diameter) and two sensor ports (2.5 mm in each outer diameter). One port had a gradient-magnetic-based tracking sensor to identify the tip position and orientation; the outer diameter and length of the endoscope were 11 and 1200 mm. A pig was scanned as a pre-procedural MR image and the result was used as navigation images to assess the endoscope's feasibility. The camera image quality was sufficient to identify organs without critical noise during scanning, and its resolution was 295 times that of the conventional MR-compatible fiber endoscope we developed. The refresh rates of the sensor position and orientation were <0.5 s, which includes data transmission from the scanner to the navigation software. The verification study showed that the proposed MR-compatible endoscope has the potential to enable a surgeon to access target organs from the outside bore while simultaneously obtaining optical and scanned images.
引用
收藏
页码:21 / 26
页数:6
相关论文
共 50 条
  • [21] A Hands-Free MR-Compatible Volumetric Ultrasound Probe for Real-Time Motion Management During External Beam Radiotherapy
    Bednarz, B.
    Lee, W.
    Mills, D.
    Shoudy, D.
    Chan, H.
    Sabatini, J.
    Fiveland, E.
    Wang, B.
    Mitra, J.
    Darrow, R.
    Culberson, W.
    Shepard, A.
    Matrosic, C.
    McMillan, A.
    Holmes, J.
    Zagzebski, J.
    Smith, S.
    Foo, T.
    MEDICAL PHYSICS, 2017, 44 (06) : 3069 - 3069
  • [22] High-Definition Video Image Mosaics in Real-Time Based on Adaptive H-SIFT
    Han, Xiaowei
    Wang, Zhiyong
    Yang, Wenjun
    PROCEEDINGS OF THE 2017 6TH INTERNATIONAL CONFERENCE ON MEASUREMENT, INSTRUMENTATION AND AUTOMATION (ICMIA 2017), 2017, 154 : 744 - 747
  • [23] Real-time multi-resolution image reconstruction for MR-guided prostate radiotherapy
    Borman, P.
    Bruijnen, T.
    Schakel, T.
    Raaymakers, B.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S518 - S519
  • [24] Intraoperative optical coherence tomography-compatible surgical instruments for real-time image-guided ophthalmic surgery
    Ehlers, Justis P.
    Uchida, Atsuro
    Srivastava, Sunil K.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (10) : 1306 - 1308
  • [25] Flexible piezoelectric sensor for real-time image-guided colonoscopies: a solution to endoscopic looping challenges in clinic
    Kenet, Adam
    Mahadevan, Eashwar
    Elangovan, Sanjay
    Yan, Justin
    Siddiq, Kamran
    Liu, Simon
    Ladwa, Amrita
    Narayanan, Roshini
    Dakkak, Jessica
    Benassi, Thomas
    Ng, Kenneth
    Manbachi, Amir
    MEDICAL IMAGING 2020: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2021, 11315
  • [26] In vivo experiments with intraluminal ultrasound applicator compatible with "real-time" MR temperature mapping, designed for oesophagus tumour ablation
    Melodelima, D
    Salomir, R
    Mougenot, C
    Theillère, Y
    Moonen, C
    Cathignol, D
    4th International Symposium on Therapeutic Ultrasound, 2005, 754 : 185 - 187
  • [27] A Real-Time Image Row-Compression Method for High-Definition USB Cameras Based on FPGA
    Xie, Longhua
    Zhang, Zhiyong
    Zhao, Tingyu
    IEEE ACCESS, 2024, 12 : 64663 - 64671
  • [28] Development of a Real-Time Image-Guided Surgery System for Stereo-Endoscopic Sinus Surgery
    Hattori, Asaki
    Suzuki, Naoki
    Otori, Nobuyoshi
    Iimura, Jiro
    Moriyama, Hiroshi
    MEDICINE MEETS VIRTUAL REALITY 17 - NEXTMED: DESIGN FOR/THE WELL BEING, 2009, 142 : 112 - 116
  • [29] MR-guided liver tumor ablation employing open high-field 1.0T MRI for image-guided brachytherapy
    Ricke, Jens
    Thormann, Markus
    Ludewig, Matthias
    Jungnickel, Kerstin
    Grosser, Oliver
    Wybranski, Christian
    Peters, Nils
    Hass, Peter
    Bunke, Juergen
    Fischbach, Frank
    EUROPEAN RADIOLOGY, 2010, 20 (08) : 1985 - 1993
  • [30] MR-guided liver tumor ablation employing open high-field 1.0T MRI for image-guided brachytherapy
    Jens Ricke
    Markus Thormann
    Matthias Ludewig
    Kerstin Jungnickel
    Oliver Grosser
    Christian Wybranski
    Nils Peters
    Peter Hass
    Jürgen Bunke
    Frank Fischbach
    European Radiology, 2010, 20 : 1985 - 1993