Development of proton CT imaging system using plastic scintillator and CCD camera

被引:19
|
作者
Tanaka, Sodai [1 ]
Nishio, Teiji [2 ,3 ]
Matsushita, Keiichiro [2 ]
Tsuneda, Masato [4 ]
Kabuki, Shigeto [5 ]
Uesaka, Mitsuru [6 ]
机构
[1] Univ Tokyo, Sch Engn, Dept Nucl Engn & Management, Bunkyo Ku, 2-11-16 Yayoi, Tokyo 1130032, Japan
[2] Hiroshima Univ, Inst Biomed & Hlth Sci, Dept Radiat Oncol, Minami Ku, 1-2-3 Kasumi, Hiroshima 7348551, Japan
[3] Hiroshima Univ, Org Leading Grad Educ Program, Minami Ku, 1-2-3 Kasumi, Hiroshima 7348551, Japan
[4] Hiroshima Univ, Grad Sch Biomed & Hlth Sci, Dept Radiat Oncol, Minami Ku, 1-2-3 Kasumi, Hiroshima 7348551, Japan
[5] Tokai Univ, Sch Med, Dept Radiat Oncol, 143 Shimokasuya Isehara, Shibuya, Kanagawa 2591193, Japan
[6] Univ Tokyo, Nucl Profess Sch, Sch Engn, Naka Ku, 22-2 Shirane Shirakata, Tokai, Ibaraki 1130032, Japan
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 11期
关键词
proton therapy; computed tomography; plastic scintillator plus CCD camera; treatment planning; range verification; COMPUTED-TOMOGRAPHY; CALIBRATION; THERAPY;
D O I
10.1088/0031-9155/61/11/4156
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A proton computed tomography (pCT) imaging system was constructed for evaluation of the error of an x-ray CT (xCT)-to-WEL (water-equivalent length) conversion in treatment planning for proton therapy. In this system, the scintillation light integrated along the beam direction is obtained by photography using the CCD camera, which enables fast and easy data acquisition. The light intensity is converted to the range of the proton beam using a light-to-range conversion table made beforehand, and a pCT image is reconstructed. An experiment for demonstration of the pCT system was performed using a 70 MeV proton beam provided by the AVF930 cyclotron at the National Institute of Radiological Sciences. Three-dimensional pCT images were reconstructed from the experimental data. A thin structure of approximately 1 mm was clearly observed, with spatial resolution of pCT images at the same level as that of xCT images. The pCT images of various substances were reconstructed to evaluate the pixel value of pCT images. The image quality was investigated with regard to deterioration including multiple Coulomb scattering.
引用
下载
收藏
页码:4156 / 4167
页数:12
相关论文
共 50 条
  • [21] Development of a high resolution gamma camera system using finely grooved GAGG scintillator
    Yamamoto, Seiichi
    Kataoka, Jun
    Oshima, Tsubasa
    Ogata, Yoshimune
    Watabe, Tadashi
    Ikeda, Hayato
    Kanai, Yasukazu
    Hatazawa, Jun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 821 : 28 - 33
  • [22] Imaging of plutonium particles using a CCD-camera-based alpha-particle imaging system
    Morishita, Yuki
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 954
  • [23] Development of liquid scintillator system for proton flux monitoring
    So, J. H.
    Kim, H. J.
    Kang, Heedong
    Park, H.
    Ryu, S.
    Jung, S. W.
    Doh, Sihong
    Kim, Sunghwan
    Kim, Kyeryung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2007, 50 (05) : 1506 - 1509
  • [24] DEVELOPMENT OF CCD IMAGING BLOCK FOR SINGLE CHIP COLOR CAMERA
    OGAWA, Y
    NAKADA, Y
    YASUI, H
    OCHI, S
    IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 1985, 31 (03) : 405 - 413
  • [25] Development of an easy-to-handle range measurement tool using a plastic scintillator for proton beam therapy
    Fukushima, Yasuhiro
    Hamada, Minoru
    Nishio, Teiji
    Maruyama, Koichi
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (22): : 5927 - 5936
  • [26] Development on TDI CCD imaging system
    Feng, Yong
    Han, Fengling
    Xu, Shiwen
    Guangxue Jishu/Optical Technique, 2000, 26 (02): : 120 - 122
  • [27] High-resolution X-ray imaging CCD camera based on a thin scintillator screen
    Tous, J.
    Blazek, K.
    Pina, L.
    Sopko, B.
    RADIATION MEASUREMENTS, 2007, 42 (4-5) : 925 - 928
  • [28] A novel approach to proton radiography and CT using a large-volume scintillator detector system
    Darne, C.
    Robertson, D.
    Alsanea, F.
    Pan, T.
    Grosshans, D.
    Beddar, S.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S931 - S932
  • [29] Quality assurance in proton beam therapy using a plastic scintillator and a commercially available digital camera (vol 18, pg 210, 2017)
    Almurayshid, Mansour
    Helo, Yusuf
    Kacperek, Andrzej
    Griffiths, Jennifer
    Hebden, Jem
    Gibson, Adam
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (07): : 322 - 322
  • [30] DEVELOPMENT OF CCD IMAGING BLOCK FOR SINGLE CHIP COLOR CAMERA.
    Ogawa, Yoshiteru
    Nakada, Yasuo
    Yasui, Hiromichi
    Ochi, Shigeyuki
    IEEE Transactions on Consumer Electronics, 1985, CE-31 (03)