Development of a high resolution gamma camera system using finely grooved GAGG scintillator

被引:22
|
作者
Yamamoto, Seiichi [1 ]
Kataoka, Jun [2 ]
Oshima, Tsubasa [2 ]
Ogata, Yoshimune [1 ]
Watabe, Tadashi [3 ]
Ikeda, Hayato [3 ]
Kanai, Yasukazu [3 ]
Hatazawa, Jun [3 ]
机构
[1] Nagoya Univ, Grad Sch Med, Radiol & Med Lab Sci, Nagoya, Aichi 4648601, Japan
[2] Waseda Univ, Res Inst Sci & Engn, Tokyo, Japan
[3] Osaka Univ, Grad Sch Med, Suita, Osaka 565, Japan
关键词
GAGG; Grooved; Gamma camera; PSPMT; High resolution; PINHOLE;
D O I
10.1016/j.nima.2016.03.060
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
High resolution gamma cameras require small pixel scintillator blocks with high light output. However, manufacturing a small pixel scintillator block is difficult when the pixel size becomes small. To solve this limitation, we developed a high resolution gamma camera system using a finely grooved Ce-doped Gd3Al2Ga3O12 (GAGG) plate. Our gamma camera's detector consists of a 1-mm-thick finely grooved GAGG plate that is optically coupled to a 1-in. position sensitive photomultiplier tube (PSPMT). The grooved GAGG plate has 0.2 x 0.2 mm pixels with 0.05-mm wide slits (between the pixels) that were manufactured using a dicing saw. We used a Hamamatsu PSPMT with a 1-in. square high quantum efficiency (HQE) PSPMT (R8900-100-C12). The energy resolution for the Co-57 gamma photons (122 keV) was 18.5% FWHM. The intrinsic spatial resolution was estimated to be 0.7-mm FVVHM. With a 0.5-mm diameter pinhole collimator mounted to its front, we achieved a high resolution, small field-of-view gamma camera. The system spatial resolution for the Co-57 gamma photons was 1.0-mm FWHM, and the sensitivity was 0.0025%, 10 mm from the collimator surface. The Tc-99m HMDP administered mouse images showed the fine structures of the mouse body's parts. Our developed high resolution small pixel GAGG gamma camera is promising for such small animal imaging. (C) 2016 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:28 / 33
页数:6
相关论文
共 50 条
  • [1] A prototype of aerial radiation monitoring system using an unmanned helicopter mounting a GAGG scintillator Compton camera
    Jiang, Jianyong
    Shimazoe, Kenji
    Nakamura, Yasuaki
    Takahashi, Hiroyuki
    Shikaze, Yoshiaki
    Nishizawa, Yukiyasu
    Yoshida, Mami
    Sanada, Yukihisa
    Torii, Tatsuo
    Yoshino, Masao
    Ito, Shigeki
    Endo, Takanori
    Tsutsumi, Kosuke
    Kato, Sho
    Sato, Hiroki
    Usuki, Yoshiyuki
    Kurosawa, Shunsuke
    Kamada, Kei
    Yoshikawa, Akira
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2016, 53 (07) : 1067 - 1075
  • [2] Development of a Prototype Detector Using APD-Arrays Coupled With Pixelized Ce:GAGG Scintillator for High Resolution Radiation Imaging
    Kamada, Kei
    Shimazoe, Kenji
    Ito, Shigeki
    Yoshino, Masao
    Endo, Takanori
    Tsutsumi, Kousuke
    Kataoka, Jun
    Kurosawa, Shunsuke
    Yokota, Yuui
    Takahashi, Hiroyuki
    Yoshikawa, Akira
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (01) : 348 - 352
  • [3] Development of a compact and high spatial resolution gamma camera system using LaBr3(Ce)
    Yamamoto, Seiichi
    Imaizumi, Masao
    Shimosegawa, Eku
    Hatazawa, Jun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 622 (01): : 261 - 269
  • [4] Development of a high-resolution Si-PM-based gamma camera system
    Yamamoto, Seiichi
    Watabe, Hiroshi
    Kanai, Yasukazu
    Imaizumi, Masao
    Watabe, Tadashi
    Shimosegawa, Eku
    Hatazawa, Jun
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (23): : 7555 - 7567
  • [5] Development of a high resolution Si-PM based compact gamma camera system
    Yamamoto, Seiichi
    Watabe, Hiroshi
    Watabe, Tadashi
    Kanai, Yasukazu
    Shimosegawa, Eku
    Hatazawa, Jun
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [6] Performance comparison of finely pixelated LYSO- and GAGG- based Si-PM gamma cameras for high resolution SPECT
    Nakanishi, Kouhei
    Yamamoto, Seiichi
    Kataoka, Jun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 872 : 107 - 111
  • [7] Development and performance evaluation of a thin GAGG:Ce scintillator plate for high resolution synchrotron radiation X-ray imaging
    Yoshino, Masao
    Yamamoto, Seiichi
    Nakanishi, Kohei
    Yogo, Katsunori
    Kamada, Kei
    Koshikawa, Nanase
    Kataoka, Jun
    Yoshikawa, Akira
    Journal of Instrumentation, 2024, 19 (10)
  • [8] INTRINSIC RESOLUTION OF A GAMMA CAMERA SYSTEM
    SVEDBERG, JB
    PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (04): : 514 - &
  • [9] Optimization of thickness of GAGG scintillator for detecting an alpha particle emitter in a field of high beta and gamma background
    Morishita, Yuki
    Yamamoto, Seiichi
    Izaki, Kenji
    Kaneko, Junichi H.
    Hoshi, Katsuya
    Torii, Tatsuo
    RADIATION MEASUREMENTS, 2018, 112 : 1 - 5
  • [10] Development of a compact scintillator-based high-resolution Compton camera for molecular imaging
    Kishimoto, A.
    Kataoka, J.
    Koide, A.
    Sueoka, K.
    Iwamoto, Y.
    Taya, T.
    Ohsuka, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 845 : 656 - 659