Revision Total Hip Arthroplasty Using Imageless Navigation With the Concept of Combined Anteversion

被引:11
|
作者
Chang, Jun-Dong [1 ]
Kim, In-Sung [1 ]
Prabhakar, Sharad [1 ]
Mansukhani, Sameer A. [1 ]
Lee, Sang-Soo [2 ]
Yoo, Je-Hyun [3 ]
机构
[1] Hallym Univ, Dept Orthopaed Surg, Dongtan Sacred Heart Hosp, 7 Keunjaebong Gil, Hwaseong Si 445907, Gyeonggi Do, South Korea
[2] Hallym Univ, Chuncheon Sacred Heart Hosp, Dept Orthopaed Surg, Coll Med, Chunchon, South Korea
[3] Hallym Univ, Coll Med, Sacred Heart Hosp, Dept Orthopaed Surg, Anyang, South Korea
来源
JOURNAL OF ARTHROPLASTY | 2017年 / 32卷 / 05期
关键词
imageless navigation; combined anteversion; revision total hip arthroplasty; component position; computer-assisted orthopaedic surgery; ACETABULAR COMPONENT; DISLOCATION; PLACEMENT;
D O I
10.1016/j.arth.2016.12.030
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The purpose of the study was to evaluate the implant positions and clinical results of revision total hip arthroplasty (THA) using an imageless navigation with the concept of combined anteversion. Methods: A total of 40 cementless revision THAs (24 men and 16 women) using an imageless navigation with the concept of combined anteversion were retrospectively evaluated. The concept of combined anteversion was applied in cup positioning based on Widmer's equation (cup anteversion + 0.7 x stem anteversion). The mean follow-up period was 80.7 months. Postoperatively, the inclination of the cup was evaluated on standard anteroposterior view of the radiograph, and the anteversion of the cup and femoral stem was evaluated using computed tomography scan. A cup inclination of 40 degrees +/- 10 degrees and combined anteversion of the cup and femoral stem of 37 degrees +/- 10 degrees based on Widmer's equation were regarded as the "safe zone." Results: The average anteversion of the revised femoral stems was 15.3 degrees +/- 2.9 degrees (range, 9.5 degrees-21.5 degrees), whereas that of the remained femoral stems was 17.4 degrees +/- 9.7 degrees (range, 4.2 degrees-29.8 degrees). The inclination, anteversion of the cup, and combined anteversion after revision THA were 42.3 degrees +/- 3.1 degrees (range, 32.1 degrees- 48.2 degrees), 25.0 degrees +/- 2.9 degrees (range, 16.9 degrees-29.5 degrees), and 36.1 degrees +/- 3.4 degrees (range, 27.2 degrees-42.9 degrees), respectively. Therefore, the position of the implants, relative to the safe zone, showed no outliers after the revision surgery. Neither dislocation nor osteolysis was observed after the surgery. Conclusion: Favorable results of this study indicate that imageless navigation helps the surgeon in placing the components of revision THA in the safe zone. This study also shows that when this safe zone is consistently obtained, then no postoperative dislocations were observed in these patients over the 6-year follow-up period. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:1576 / 1580
页数:5
相关论文
共 50 条
  • [31] Clinical effects of combined anteversion and offset on postoperative dislocation in total hip arthroplasty
    Hidaka, Ryo
    Matsuda, Kenta
    Nakamura, Shigeru
    Nakamura, Masaki
    Kawano, Hirotaka
    ARTHROPLASTY, 2024, 6 (01)
  • [32] Differences in range of motion with the same combined anteversion after total hip arthroplasty
    Ohmori, Takaaki
    Kabata, Tamon
    Kajino, Yoshitomo
    Taga, Tadashi
    Hasegawa, Kazuhiro
    Inoue, Daisuke
    Yamamoto, Takashi
    Takagi, Tomoharu
    Yoshitani, Junya
    Ueno, Takuro
    Tsuchiya, Hiroyuki
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (05) : 1021 - 1028
  • [33] Imageless navigation of hip resurfacing arthroplasty increases the implant accuracy
    C. Schnurr
    J. W. P. Michael
    P. Eysel
    D. P. König
    International Orthopaedics, 2009, 33 : 365 - 372
  • [34] Imageless navigation of hip resurfacing arthroplasty increases the implant accuracy
    Schnurr, C.
    Michael, J. W. P.
    Eysel, P.
    Koenig, D. P.
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (02) : 365 - 372
  • [35] The value of computed tomography based navigation in revision total hip arthroplasty
    Kuroda, Kazunari
    Kabata, Tamon
    Maeda, Toru
    Kajino, Yoshitomo
    Watanabe, Shin
    Iwai, Shintaro
    Kenji, Fujita
    Hasegawa, Kazuhiro
    Inoue, Daisuke
    Tsuchiya, Hiroyuki
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (04) : 711 - 716
  • [36] Computer Navigation for Revision Total Hip Arthroplasty Reduces Dislocation Rates
    Sharma, Abhinav K.
    Cizmic, Zlatan
    Carroll, Kaitlin M.
    Jerabek, Seth A.
    Paprosky, Wayne G.
    Sculco, Peter K.
    Gonzalez Della Valle, Alejandro
    Schwarzkopf, Ran
    Mayman, David J.
    Vigdorchik, Jonathan M.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2022, 56 (06) : 1061 - 1065
  • [37] Computer Navigation for Revision Total Hip Arthroplasty Reduces Dislocation Rates
    Abhinav K. Sharma
    Zlatan Cizmic
    Kaitlin M. Carroll
    Seth A. Jerabek
    Wayne G. Paprosky
    Peter K. Sculco
    Alejandro Gonzalez Della Valle
    Ran Schwarzkopf
    David J. Mayman
    Jonathan M. Vigdorchik
    Indian Journal of Orthopaedics, 2022, 56 : 1061 - 1065
  • [38] The value of computed tomography based navigation in revision total hip arthroplasty
    Kazunari Kuroda
    Tamon Kabata
    Toru Maeda
    Yoshitomo Kajino
    Shin Watanabe
    Shintaro Iwai
    Fujita Kenji
    Kazuhiro Hasegawa
    Daisuke Inoue
    Hiroyuki Tsuchiya
    International Orthopaedics, 2014, 38 : 711 - 716
  • [39] Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography
    Axel Marx
    Marius von Knoch
    Jörg Pförtner
    Matthias Wiese
    Guido Saxler
    Archives of Orthopaedic and Trauma Surgery, 2006, 126 : 487 - 492
  • [40] Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography
    Marx, Axel
    von Knoch, Marius
    Pfoertner, Joerg
    Wiese, Matthias
    Saxler, Guido
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2006, 126 (07) : 487 - 492