Continuous flow immunosensor for atrazine detection

被引:19
|
作者
Vianello, F
Signor, L
Pizzariello, A
Di Paolo, ML
Scarpa, M
Hock, B
Giersch, T
Rigo, A
机构
[1] Univ Padua, Dept Biol Chem, I-35121 Padua, Italy
[2] Univ Trent, Dept Phys, Trent, Italy
[3] Tech Univ Munich, Dept Bot, D-8000 Munich, Germany
来源
BIOSENSORS & BIOELECTRONICS | 1998年 / 13卷 / 01期
关键词
atrazine; antibodies; alkaline phosphatase; enzyme amplification; electrocatalytic currents;
D O I
10.1016/S0956-5663(97)00079-1
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The hapten atrazine was detected under continuous flow conditions using a micro-column which contained immobilized monoclonal antibodies (Ab) against atrazine and atrazine labeled with alkaline phosphatase (An*). The equilibrium of the antibody-hapten system, was achieved by a continuous flow of the tracer An* through the micro-column containing the immobilized antibodies. The activity of the tracer was monitored continuously, after the micro-column, by an amperometric detector using p-hydroquinone phosphate as substrate. When pulses of unlabeled atrazine (An) were added to the An* flowing continuously through the micro-column, An* bound to the antibody was displaced, with a consequent change of the detector signal. By this method atrazine concentrations in the range 9-180 mu g/l were monitored under conditions of continuous operation. Since the equilibrium condition for the system Ab-An* was continuously restored by the flow of An* through the micro-column the regeneration of the antibody was not required. (C) 1997 Elsevier Science Limited.
引用
收藏
页码:45 / 53
页数:9
相关论文
共 50 条
  • [41] Kinetic modelling of aqueous atrazine ozonation processes in a continuous flow bubble contactor
    Beltrán, FJ
    González, M
    Acedo, B
    Rivas, FJ
    JOURNAL OF HAZARDOUS MATERIALS, 2000, 80 (1-3) : 189 - 206
  • [42] Electrochemical lateral flow immunosensor with enhanced reproducibility for milk allergen detection
    Kunpatee, Kanjana
    Panphloi, Muthita
    Charoenkitamorn, Kanokwan
    Pimpitak, Umaporna
    Puthong, Songchan
    Buakeaw, Anumart
    Komolpis, Kittinan
    Sain, Mohini M.
    Yakoh, Abdulhadee
    Chaiyo, Sudkate
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 401
  • [43] Atrazine-Based Self-Assembled Monolayers and Their Interaction with Anti-Atrazine Antibody: Building of an Immunosensor
    Hromadova, Magdalena
    Pospisil, Lubomir
    Sokolova, Romana
    Bulickova, Jana
    Hof, Martin
    Fischer-Durand, Nathalie
    Salmain, Michele
    LANGMUIR, 2013, 29 (52) : 16084 - 16092
  • [44] Fabrication of an Atrazine Acoustic Immunosensor Based on a Drop-Deposition Procedure
    Jia, Kun
    Toury, Timothee
    Ionescu, Rodica Elena
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (09) : 2015 - 2021
  • [45] Zearalenone determination in corn silage samples using an immunosensor in a continuous-flow/stopped-flow systems
    Panini, Nancy V.
    Bertolino, Franco A.
    Salinas, Eloy
    Messina, German A.
    Raba, Julio
    BIOCHEMICAL ENGINEERING JOURNAL, 2010, 51 (1-2) : 7 - 13
  • [46] A gold nanoparticle-based lateral flow immunosensor for ultrasensitive detection of tetrodotoxin
    Li, Yue
    Xu, Xinxin
    Liu, Liqiang
    Kuang, Hua
    Xu, Liguang
    Xu, Chuanlai
    ANALYST, 2020, 145 (06) : 2143 - 2151
  • [47] Rapid and Sensitive Detection of Nanomolecules by an AC Electrothermal Flow Facilitated Impedance Immunosensor
    Koklu, Anil
    Giuliani, Jason
    Monton, Carlos
    Beskok, Ali
    ANALYTICAL CHEMISTRY, 2020, 92 (11) : 7762 - 7769
  • [48] Optical flow-cell multichannel immunosensor for the detection of biological warfare agents
    Koch, S
    Wolf, H
    Danapel, C
    Feller, KA
    BIOSENSORS & BIOELECTRONICS, 2000, 14 (10-11): : 779 - 784
  • [49] Fabrication of flexible interdigitated μ-electrodes (FIDμEs) for the development of a conductimetric immunosensor for atrazine detection based on antibodies labelled with gold nanoparticles
    Valera, Enrique
    Muniz, David
    Rodriguez, Angel
    MICROELECTRONIC ENGINEERING, 2010, 87 (02) : 167 - 173
  • [50] SYNTHESIS OF A FLUORESCENT ANALOG OF POLYCHLORINATED-BIPHENYLS FOR USE IN A CONTINUOUS-FLOW IMMUNOSENSOR ASSAY
    CHARLES, PT
    CONRAD, DW
    JACOBS, MS
    BART, JC
    KUSTERBECK, AW
    BIOCONJUGATE CHEMISTRY, 1995, 6 (06) : 691 - 694