Continuous flow immunosensor for atrazine detection

被引:19
|
作者
Vianello, F
Signor, L
Pizzariello, A
Di Paolo, ML
Scarpa, M
Hock, B
Giersch, T
Rigo, A
机构
[1] Univ Padua, Dept Biol Chem, I-35121 Padua, Italy
[2] Univ Trent, Dept Phys, Trent, Italy
[3] Tech Univ Munich, Dept Bot, D-8000 Munich, Germany
来源
BIOSENSORS & BIOELECTRONICS | 1998年 / 13卷 / 01期
关键词
atrazine; antibodies; alkaline phosphatase; enzyme amplification; electrocatalytic currents;
D O I
10.1016/S0956-5663(97)00079-1
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The hapten atrazine was detected under continuous flow conditions using a micro-column which contained immobilized monoclonal antibodies (Ab) against atrazine and atrazine labeled with alkaline phosphatase (An*). The equilibrium of the antibody-hapten system, was achieved by a continuous flow of the tracer An* through the micro-column containing the immobilized antibodies. The activity of the tracer was monitored continuously, after the micro-column, by an amperometric detector using p-hydroquinone phosphate as substrate. When pulses of unlabeled atrazine (An) were added to the An* flowing continuously through the micro-column, An* bound to the antibody was displaced, with a consequent change of the detector signal. By this method atrazine concentrations in the range 9-180 mu g/l were monitored under conditions of continuous operation. Since the equilibrium condition for the system Ab-An* was continuously restored by the flow of An* through the micro-column the regeneration of the antibody was not required. (C) 1997 Elsevier Science Limited.
引用
收藏
页码:45 / 53
页数:9
相关论文
共 50 条
  • [31] An electrochemical immunosensor for milk progesterone using a continuous flow system
    Pemberton, RM
    Hart, JP
    Mottram, TT
    BIOSENSORS & BIOELECTRONICS, 2001, 16 (9-12): : 715 - 723
  • [32] A displacement flow immunosensor for explosive detection using microcapillaries
    Narang, U
    Gauger, PR
    Ligler, FS
    ANALYTICAL CHEMISTRY, 1997, 69 (14) : 2779 - 2785
  • [33] Infrared optical immunosensor: Application to the measurement of the herbicide atrazine
    Salmain, Michele
    Fischer-Durand, Nathalie
    Pradier, Claire-Marie
    ANALYTICAL BIOCHEMISTRY, 2008, 373 (01) : 61 - 70
  • [34] TOWARDS A CONTINUOUS IMMUNOSENSOR
    不详
    LANCET, 1991, 337 (8743): : 726 - 726
  • [35] Development of a highly sensitive noncompetitive electrochemical immunosensor for the detection of atrazine by phage anti-immunocomplex assay
    Gonzalez-Techera, Andres
    Alicia Zon, Maria
    Gabriela Molina, Patricia
    Fernandez, Hector
    Gonzalez-Sapienza, Gualberto
    Javier Arevalo, Fernando
    BIOSENSORS & BIOELECTRONICS, 2015, 64 : 650 - 656
  • [36] Multianalyte detection using a capillary-based flow immunosensor
    Narang, U
    Gauger, PR
    Kusterbeck, AW
    Ligler, FS
    ANALYTICAL BIOCHEMISTRY, 1998, 255 (01) : 13 - 19
  • [37] Analytical Application of Flow Immunosensor in Detection of Thyroxine and Triiodothyronine in Serum
    Wani, Tanveer A.
    Zargar, Seema
    Majid, Salma
    Darwish, Ibrahim A.
    ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2016, 14 (09) : 535 - 542
  • [38] FIBER-OPTIC BIOSENSOR FOR THE DETECTION OF ATRAZINE: CHARACTERIZATION AND CONTINUOUS MEASUREMENTS
    Das, Neema
    Reardon, Kenneth F.
    ANALYTICAL LETTERS, 2012, 45 (2-3) : 251 - 261
  • [39] Separation-free electrochemical immunosensor for rapid determination of atrazine
    Keay, RW
    McNeil, CJ
    BIOSENSORS & BIOELECTRONICS, 1998, 13 (09): : 963 - 970
  • [40] Construction and characterization of the direct piezoelectric immunosensor for atrazine operating in solution
    Steegborn, C
    Skladal, P
    BIOSENSORS & BIOELECTRONICS, 1997, 12 (01): : 19 - 27