Oxygen Uptake Rate Measurement Using Kalman Filter and PWM Control in Activated Sludge Systems

被引:8
|
作者
Silva, Francisco Jadilson dos S. [1 ]
Catunda, Sebastian Yuri C. [2 ]
Dorea, Carlos E. T. [2 ]
van Haandel, Adrianus C. [3 ]
dos Santos, Helio Rodrigues [4 ]
机构
[1] Fed Inst Maranhao, Dept Tech Educ, BR-65250000 Alcantara, Brazil
[2] Univ Fed Rio Grande do Norte, Dept Comp Engn & Automat, BR-59078970 Natal, RN, Brazil
[3] Univ Fed Campina Grande, Dept Civil Engn, Campina Grande, Brazil
[4] Univ Fed Rio Grande do Norte, Dept Civil Engn, BR-59078970 Natal, RN, Brazil
关键词
Estimation; Standards; Pulse width modulation; Inductors; Oxygen; Kalman filters; Microorganisms; Activated sludge; dissolved oxygen; Kalman filter; oxygen uptake rate; PWM control; wastewater treatment; WASTE-WATER; RESPIROMETRY; AUTOMATION;
D O I
10.1109/TIM.2018.2886941
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The availability of real-time information about the biological activity is a valuable matter in wastewater treatment employing activated sludge processes, and this is represented by the oxygen uptake rate (OUR). In these processes, OUR measurements have been used as a fast indicator of changes in waste load or influx of toxic organic compounds and for monitoring of the process efficiency. In this paper, we propose a method for OUR estimation by using Kalman filters and PWM control of the dissolved oxygen (DO) concentration in the activated sludge reactor. The proposed method presents a shorter response time than the standard online procedure and a lower measurement uncertainty compared to a previous feedback control method, which estimates the OUR from values of the applied control signal and the DO concentration measurements. Simulations are presented to illustrate the method and experiments are performed in a bench scale activated sludge reactor to show the applicability of the proposed estimator in a real system. The results confirm the fast response of the proposed method and its consistency with respect to the standard procedure for OUR computation.
引用
收藏
页码:4493 / 4501
页数:9
相关论文
共 50 条
  • [21] EVALUATION OF OXYGEN-UPTAKE RATE AS AN ACTIVATED-SLUDGE PROCESS-CONTROL PARAMETER - DISCUSSION
    VARGASLOPEZ, CE
    STENTIFORD, EI
    MARA, DD
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1989, 61 (01): : 99 - 102
  • [22] MEASUREMENT AND VALIDITY OF OXYGEN-UPTAKE AS AN ACTIVATED-SLUDGE PROCESS-CONTROL PARAMETER - REPLY
    EDWARDS, GL
    SHERRARD, JH
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1984, 56 (01): : 112 - 112
  • [23] MEASUREMENT AND VALIDITY OF OXYGEN-UPTAKE AS AN ACTIVATED-SLUDGE PROCESS-CONTROL PARAMETER - DISCUSSION
    ARTHUR, RM
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1984, 56 (01): : 111 - 112
  • [24] EVALUATION OF ACTIVATED-SLUDGE OXYGEN-UPTAKE RATE TEST PROCEDURES
    CHIESA, SC
    RIETH, MG
    CHING, TEKL
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1990, 116 (03): : 472 - 486
  • [25] PWM variable spray control based on Kalman filter
    Jiang, Huanyu
    Zhou, Mingchuan
    Tong, Junhua
    Liu, Yan
    Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery, 2014, 45 (10): : 60 - 65
  • [26] SPECIFIC OXYGEN UTILIZATION RATE FOR CONTROL OF ACTIVATED-SLUDGE PROCESS
    ANDREWS, JF
    PROGRESS IN WATER TECHNOLOGY, 1977, 8 (06): : 451 - 460
  • [27] THE SIGNIFICANCE OF OXYGEN-UPTAKE RATES ON THE OPERATION OF ACTIVATED-SLUDGE SYSTEMS
    FORSTER, CF
    SURENDRA, M
    WATT, S
    BIOTECHNOLOGY LETTERS, 1980, 2 (07) : 327 - 332
  • [28] The relation between oxygen uptake rate and biosorption of activated sludge against chemical substance
    Mihara, Y
    Inoue, T
    Yokota, K
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2005, 125 (02): : 225 - 229
  • [29] Fast on-line measurement of the respiration rate in activated sludge systems
    Catunda, SYC
    Deep, GS
    vanHaandel, AC
    Freire, RCS
    JOINT CONFERENCE - 1996: IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE & IMEKO TECHNICAL COMMITTEE 7, CONFERENCE PROCEEDINGS, VOLS I AND II: QUALITY MEASUREMENTS: THE INDISPENSABLE BRIDGE BETWEEN THEORY AND REALITY (NO MEASUREMENTS? NO SCIENCE!), 1996, : 1320 - 1325
  • [30] Oxygen Uptake Rate Tests to Evaluate Integrated Fixed Film Activated Sludge Processes
    Maas, Carol L. A.
    Parker, Wayne J.
    Legge, Raymond L.
    WATER ENVIRONMENT RESEARCH, 2008, 80 (12) : 2276 - 2283