Oxygen Uptake Rate Measurement Using Kalman Filter and PWM Control in Activated Sludge Systems

被引:8
|
作者
Silva, Francisco Jadilson dos S. [1 ]
Catunda, Sebastian Yuri C. [2 ]
Dorea, Carlos E. T. [2 ]
van Haandel, Adrianus C. [3 ]
dos Santos, Helio Rodrigues [4 ]
机构
[1] Fed Inst Maranhao, Dept Tech Educ, BR-65250000 Alcantara, Brazil
[2] Univ Fed Rio Grande do Norte, Dept Comp Engn & Automat, BR-59078970 Natal, RN, Brazil
[3] Univ Fed Campina Grande, Dept Civil Engn, Campina Grande, Brazil
[4] Univ Fed Rio Grande do Norte, Dept Civil Engn, BR-59078970 Natal, RN, Brazil
关键词
Estimation; Standards; Pulse width modulation; Inductors; Oxygen; Kalman filters; Microorganisms; Activated sludge; dissolved oxygen; Kalman filter; oxygen uptake rate; PWM control; wastewater treatment; WASTE-WATER; RESPIROMETRY; AUTOMATION;
D O I
10.1109/TIM.2018.2886941
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The availability of real-time information about the biological activity is a valuable matter in wastewater treatment employing activated sludge processes, and this is represented by the oxygen uptake rate (OUR). In these processes, OUR measurements have been used as a fast indicator of changes in waste load or influx of toxic organic compounds and for monitoring of the process efficiency. In this paper, we propose a method for OUR estimation by using Kalman filters and PWM control of the dissolved oxygen (DO) concentration in the activated sludge reactor. The proposed method presents a shorter response time than the standard online procedure and a lower measurement uncertainty compared to a previous feedback control method, which estimates the OUR from values of the applied control signal and the DO concentration measurements. Simulations are presented to illustrate the method and experiments are performed in a bench scale activated sludge reactor to show the applicability of the proposed estimator in a real system. The results confirm the fast response of the proposed method and its consistency with respect to the standard procedure for OUR computation.
引用
收藏
页码:4493 / 4501
页数:9
相关论文
共 50 条
  • [11] NITRIFICATION PROCESS-CONTROL IN ACTIVATED-SLUDGE USING OXYGEN-UPTAKE RATE MEASUREMENTS
    SURMACZGORSKA, J
    GERNAEY, K
    DEMUYNCK, C
    VANROLLEGHEM, P
    VERSTRAETE, W
    ENVIRONMENTAL TECHNOLOGY, 1995, 16 (06) : 569 - 577
  • [12] EFFLUENT QUALITY-CONTROL IN THE ACTIVATED-SLUDGE PROCESS USING OXYGEN-UPTAKE RATE
    ECKENFELDER, WW
    JAFFEE, PR
    ENVIRONMENTAL TECHNOLOGY LETTERS, 1982, 3 (10): : 441 - 448
  • [13] The impact of slowly biodegradable organic compounds on the oxygen uptake rate in activated sludge systems
    Drewnowski, J.
    WATER SCIENCE AND TECHNOLOGY, 2014, 69 (06) : 1136 - 1144
  • [14] Influences of drugs on the oxygen uptake rate and biosorption of activated sludge
    Kumagai, T
    Inoue, T
    Mihara, Y
    Ebina, K
    Yokota, K
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2006, 29 (01) : 183 - 186
  • [15] EVALUATION OF OXYGEN-UPTAKE RATE AS AN ACTIVATED-SLUDGE PROCESS-CONTROL PARAMETER
    CHANDRA, S
    MINES, RO
    SHERRARD, JH
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1987, 59 (12): : 1009 - 1016
  • [16] MEASUREMENT AND VALIDITY OF OXYGEN-UPTAKE AS AN ACTIVATED-SLUDGE PROCESS-CONTROL PARAMETER
    EDWARDS, GL
    SHERRARD, JH
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1982, 54 (12): : 1546 - 1552
  • [17] Nitrification monitoring in activated sludge by oxygen uptake rate (OUR) measurements
    SurmaczGorska, J
    Gernaey, K
    Demuynck, C
    Vanrolleghem, P
    Verstraete, W
    WATER RESEARCH, 1996, 30 (05) : 1228 - 1236
  • [18] Disturbance Observer for Estimation of Oxygen Uptake Rate in an Activated Sludge Reactor
    dos Santos Silva, Francisco Jadilson
    de Macedo, Euler C. T.
    Catunda, Sebastian Y. C.
    Dorea, Carlos E. T.
    Van Haandel, Adrianus C.
    2016 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE PROCEEDINGS, 2016, : 1070 - 1075
  • [19] Oxygen uptake in the activated sludge process
    Giona, A.R.
    Annesini, M.C.
    Journal of the Water Pollution Control Federation, 1979, 51 (05): : 1009 - 1016
  • [20] EVALUATION OF OXYGEN-UPTAKE RATE AS AN ACTIVATED-SLUDGE PROCESS-CONTROL PARAMETER - RESPONSE
    CHANDRA, S
    MINES, RO
    SHERRARD, JH
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1989, 61 (01): : 102 - 102