Effect of heat sterilization and chemical method of sterilization on the polyvinyl siloxane impression material. A comparative study

被引:4
|
作者
Asopa, Swati Joshi [1 ]
Padiyar, U. Narendra [2 ]
Verma, Sumit [3 ]
Suri, Prerna
Somayaji, Nagaveni S. [4 ]
Radhakrishnan, Indu Cherangapadath
机构
[1] Rajasthan Dent Coll & Hosp, Dept Prosthodont Crown & Bridge, Jaipur, Rajasthan, India
[2] Mahatma Gandhi Dent Coll & Hosp, Dept Prosthodont Crown & Bridge, Jaipur, Rajasthan, India
[3] Dr BR Ambedkar Inst Dent Sci & Hosp, Dept Oral & Maxillofacial Surg, Patna, Bihar, India
[4] Hitech Dent Coll & Hosp, Dept Prosthodont Crown & Bridge, Bhubaneswar, Odisha, India
关键词
Impression material; polyvinyl siloxanes; sterilization; DIMENSIONAL STABILITY; DISINFECTION; ACCURACY; EFFICACY;
D O I
10.4103/jfmpc.jfmpc_1122_19
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Dental impression is a crucial part of the process of constructing a well-fitting prosthesis. In the clinical scenario, impressions can act as a vehicle for the transfer of bacteria and fungi. Therefore, an attempt was made to evaluate the dimensional accuracy of the newly introduced polyvinyl siloxane (PVS) impression material upon autoclaving and comparing it to the traditional means of chemical disinfection. Materials and Methods: A cross-sectional comparative in vitro study was conducted. Three groups were made for testing different sterilization methods. The sample size for the study was kept as 30 observations in each of the three groups. Test samples were prepared by making an impression of the die using the putty-wash technique. Statistical analysis was done by applying unpaired t-test, paired t-test, one-way analysis of variance (ANOVA) and post hoc Tukey's honestly significant difference (HSD). Results: Initial mean of samples of group I were compared to A (actual measurement of metal ruled block = 24.960), a dimensional change of 1.6% was found. Similarly, in group II, a change of 1.59% was found and in group III the change was 1.7%. There was mean shrinkage of 24.557 mm in group I, 24.586 mm in group II, and 24.535 mm in group III and these changes were found statistically significant. Conclusion: Dimensional changes in the impression material after disinfection with 2% glutaraldehyde were considered high compared to autoclaving and, hence, it may not be advisable to disinfect this material with 2% glutaraldehyde.
引用
收藏
页码:1348 / 1353
页数:6
相关论文
共 37 条
  • [1] Effect of provisional luting agents on polyvinyl siloxane impression material
    Jones, RH
    Cook, GS
    Moon, MG
    JOURNAL OF PROSTHETIC DENTISTRY, 1996, 75 (04): : 360 - 363
  • [2] Effect of polyvinyl siloxane impression material on the polymerization of composite resin
    Chen, Liang
    Kleverlaan, Cornelis Johannes
    Liang, Kunneng
    Yang, Deqin
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (04): : 552 - 558
  • [3] Study of sterilization method for hybrid material for medical
    Tashiro, Ayaka
    Inoue, Yusuke
    Isoyama, Takashi
    Saito, Itsuro
    Ono, Toshiya
    Sato, Masami
    Hara, Shintaro
    Yurimoto, Terumi
    Li, Xinyang
    Murakami, Haruka
    Kawase, Yukino
    Maeno, Erina
    Imachi, Ko
    Kumagai, Hiroshi
    Abe, Yusuke
    Transactions of Japanese Society for Medical and Biological Engineering, 2014, 52
  • [4] The effect of various base/core materials on the setting of a polyvinyl siloxane impression material
    Moon, MG
    Jarrett, TA
    Morlen, RA
    Fallo, GJ
    JOURNAL OF PROSTHETIC DENTISTRY, 1996, 76 (06): : 608 - 612
  • [5] Effect of chemical disinfection on the dimensional stability of polyvinyl ether siloxane impression material: a systemic review and meta-analysis
    Saeed Awod Bin Hassan
    Abdulkhaliq Ali F Alshadidi
    Lujain Ibrahim N Aldosari
    Artak Heboyan
    Ravinder S Saini
    BMC Oral Health, 23
  • [6] Effect of chemical disinfection on the dimensional stability of polyvinyl ether siloxane impression material: a systemic review and meta-analysis
    Bin Hassan, Saeed Awod
    Alshadidi, Abdulkhaliq Ali F.
    Aldosari, Lujain Ibrahim N.
    Heboyan, Artak
    Saini, Ravinder S.
    BMC ORAL HEALTH, 2023, 23 (01)
  • [7] Compatibility of Novel Gingival Retraction Pastes Based on Boswellia papyrifera with Polyvinyl Siloxane Impression Material (A Comparative in-vitro Study)
    Salman, Hiba A.
    Majeed, Manhal A.
    Al-Rubaee, Eaman A.
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2021, 9 (07): : 127 - 132
  • [8] Accuracy of Impression Material During COVID-19 after Sterilization-In vitro Study
    Alhaddad, Abdulrahman Jafar
    JOURNAL OF PHARMACEUTICAL RESEARCH INTERNATIONAL, 2021, 33 (50B) : 241 - 246
  • [9] Effect of Different Viscosity and Tear Strength of Polyvinyl Siloxane Impression Material on the Accuracy of Dental Implant Impressions
    Haider, Yagthan Mohammed
    Mokhtar, Norehan
    Najim, Zubaida Tariq
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2018, 7 (12): : 101 - 109
  • [10] EFFECT OF IMPRESSION TRAY DESIGN AND IMPRESSION TECHNIQUE UPON THE ACCURACY OF STONE CASTS PRODUCED FROM A PUTTY-WASH POLYVINYL SILOXANE IMPRESSION MATERIAL
    SAUNDERS, WP
    SHARKEY, SW
    SMITH, GM
    TAYLOR, WG
    JOURNAL OF DENTISTRY, 1991, 19 (05) : 283 - 289