Effect of heat sterilization and chemical method of sterilization on the polyvinyl siloxane impression material. A comparative study

被引:4
|
作者
Asopa, Swati Joshi [1 ]
Padiyar, U. Narendra [2 ]
Verma, Sumit [3 ]
Suri, Prerna
Somayaji, Nagaveni S. [4 ]
Radhakrishnan, Indu Cherangapadath
机构
[1] Rajasthan Dent Coll & Hosp, Dept Prosthodont Crown & Bridge, Jaipur, Rajasthan, India
[2] Mahatma Gandhi Dent Coll & Hosp, Dept Prosthodont Crown & Bridge, Jaipur, Rajasthan, India
[3] Dr BR Ambedkar Inst Dent Sci & Hosp, Dept Oral & Maxillofacial Surg, Patna, Bihar, India
[4] Hitech Dent Coll & Hosp, Dept Prosthodont Crown & Bridge, Bhubaneswar, Odisha, India
关键词
Impression material; polyvinyl siloxanes; sterilization; DIMENSIONAL STABILITY; DISINFECTION; ACCURACY; EFFICACY;
D O I
10.4103/jfmpc.jfmpc_1122_19
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Dental impression is a crucial part of the process of constructing a well-fitting prosthesis. In the clinical scenario, impressions can act as a vehicle for the transfer of bacteria and fungi. Therefore, an attempt was made to evaluate the dimensional accuracy of the newly introduced polyvinyl siloxane (PVS) impression material upon autoclaving and comparing it to the traditional means of chemical disinfection. Materials and Methods: A cross-sectional comparative in vitro study was conducted. Three groups were made for testing different sterilization methods. The sample size for the study was kept as 30 observations in each of the three groups. Test samples were prepared by making an impression of the die using the putty-wash technique. Statistical analysis was done by applying unpaired t-test, paired t-test, one-way analysis of variance (ANOVA) and post hoc Tukey's honestly significant difference (HSD). Results: Initial mean of samples of group I were compared to A (actual measurement of metal ruled block = 24.960), a dimensional change of 1.6% was found. Similarly, in group II, a change of 1.59% was found and in group III the change was 1.7%. There was mean shrinkage of 24.557 mm in group I, 24.586 mm in group II, and 24.535 mm in group III and these changes were found statistically significant. Conclusion: Dimensional changes in the impression material after disinfection with 2% glutaraldehyde were considered high compared to autoclaving and, hence, it may not be advisable to disinfect this material with 2% glutaraldehyde.
引用
收藏
页码:1348 / 1353
页数:6
相关论文
共 37 条
  • [31] Effect of different sterilization methods on load-deflection characteristics of two grades of copper NiTi wires with different transition temperature range: A comparative in vitro study
    Singaraju, Gowri Sankar
    Naidu, N.V.P.
    Teja, Naga Ravi
    Reddy, V. Karunakara
    Ganugapanta, Vivek Reddy
    Mandava, Prasad
    Trends in Biomaterials and Artificial Organs, 2021, 35 (02): : 129 - 136
  • [32] Effect of heat shock and chemical stress on oocyte maturation:: A comparative study in Xenopus and Rana dybowskii
    Chatterjee, A
    Bandyopadhyay, A
    Kwon, HB
    Choi, HS
    RECENT PROGRESS IN MOLECULAR AND COMPARATIVE ENDOCRINOLOGY, 1999, : 395 - 400
  • [33] Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene - A hip-simulator study
    McKellop, H
    Shen, FW
    Lu, B
    Campbell, P
    Salovey, R
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (12): : 1708 - 1725
  • [34] A comparative study of the effect of varying wall heat flux on melting characteristics of phase change material RT44HC in rectangular test cells
    Fadl, Mohamed
    Eames, Philip C.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 141 : 731 - 747
  • [35] Study of the effect of heat temperature on the chemical changes and hygroscopicity of eucalyptus wood by FT-IR and prediction of mechanical properties by the MLR regression method
    Elrhayam, Youssef
    El Bachiri, Abderrahim
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 321
  • [36] Effect of Surface Treatments with Plasma and Chemical Bond on Shear Bond Strength of Acrylic Denture Teeth to Flexible and Heat-Cured Denture Base Material: An In Vitro Study
    Abood, Ghazwan A.
    Mohammed, Ali A.
    Abdullah, Zainab S.
    Fatalla, Abdalbseet A.
    DENTAL HYPOTHESES, 2024, 15 (01): : 8 - 10
  • [37] RETRACTION: RETRACTED: Effect of Low Heat Steam Sterilization to the Volumetric Stability of three Different 3D Printing Materials for Dental Implant Surgical Templates. An In Vitro Study (Retraction of Vol 17, art no E184742106264110, 2023) (Retracted article. See vol. 17, 2023)
    Tachmatzidis, Theodoros
    Fotopoulos, Ioannis
    Lillis, Theodoros
    Kapagiannidis, Ioannis
    Dabarakis, Nikolaos
    OPEN DENTISTRY JOURNAL, 2023, 17