Radiation characteristics and hypo-fractionation dose response for the DVS implantable MOSFET dosimeter

被引:1
|
作者
Beyer, G. P.
Pursley, J.
Mann, G.
Espenhahn, E.
Fraisse, C.
Godfrey, D.
Oldham, M.
机构
[1] Sicel Technologies Inc, Morrisville, NC USA
[2] Duke Univ, Med Ctr, Durham, NC 27706 USA
关键词
D O I
10.1118/1.2761596
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Evaluation of the radiation characteristics and performance of the DVS® implantable MOSFET dosimeter for typical and hypo‐fractionated protocols. Method and Materials: The commercially available DVS is calibrated for use in the range of 150–250 cGy per fraction up to 80 Gy. The dosimeter was evaluated to determine its radiation characteristics, including response to energy, angular dependence, temperature, and dose shadowing. Dosimeter performance was also validated in a phantom simulating different radiation treatment conditions. A high dose calibrated dosimeter for use with hypo‐fractionated protocols is introduced. Phantom measurements were performed to validate this dosimeter in the dose per fraction range of 400–1200 cGy. All phantom data was validated using a NIST‐traceable calibrated ion chamber. Results: The DVS was found to have a very small energy dependency (⩽1.5%) in the [formula omitted]‐18 MV range. With kV onboard imaging, an over‐response was only measurable for doses from kV‐CBCT. The radial angular dependence was found to be within 1.4% and the maximum angular dependence (6%) was obtained for beams traveling through the coil and electronics. A dosimeter implanted in close parallel alignment with the sagittal body axis would minimize this effect. Since the DVS is calibrated at 37°C (for use at body temperature), measurements performed at room temperature require a correction factor of approximately 1.033. Phantom measurements (23°C, 37°C) resulted in values well within the specified accuracy of 5%. The dosimeter calibrated for use in hypo‐fractionation applications resulted in an average variability of −0.3% (σ=2.2%) from predicted dose in the range of 400–1200cGy per fraction. Conclusions: This data suggests that DVS can be used, together with current delivery and planning techniques, to optimize radiation treatment by measuring the dose delivered in the treatment area. Testing shows the potential to use the high‐dose calibrated dosimeter with hypo‐fractionated radiation treatments. Research sponsored by Sicel Technologies, Inc. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2610 / 2610
页数:1
相关论文
共 50 条
  • [31] CORRELATION BETWEEN MOSFET DOSIMETER ENERGY RESPONSE AND ITS SHIELDING MATERIAL IN ELECTRON-BEAM RADIATION ENVIRONMENT
    Stankovic, S. J.
    Ilic, R. D.
    Lazarevic, Dj.
    Fetahovic, I.
    Obrenovic, M.
    Iricanin, B.
    2015 IEEE PULSED POWER CONFERENCE (PPC), 2015,
  • [32] RADIATION-INDUCED OPTIC NEUROPATHY: DOSE RESPONSE AND MODELING TOTAL DOSE AND FRACTIONATION.
    Bhandare, N.
    Song, W.
    Moiseenko, V.
    Robert, M.
    Mendenhall, W.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S266 - S266
  • [33] Adapting Radiation Therapy Treatments for Patients with Breast Cancer During the COVID-19 Pandemic: Hypo-Fractionation and Accelerated Partial Breast Irradiation to Address World Health Organization Recommendations
    Al-Rashdan, Abdulla
    Roumeliotis, Michael
    Quirk, Sarah
    Grendarova, Petra
    Phan, Tien
    Cao, Jeffery
    Logie, Natalie
    Smith, Wendy
    Barbera, Lisa
    ADVANCES IN RADIATION ONCOLOGY, 2020, 5 (04) : 575 - 576
  • [34] RADIATION DOSE-RESPONSE CHARACTERISTICS OF LEUCOCYTES IN MOUSE
    SMITH, WW
    CORNFIELD, J
    SCHNEIDER, CA
    ALDERMAN, IM
    PROCEEDINGS OF THE SOCIETY FOR EXPERIMENTAL BIOLOGY AND MEDICINE, 1962, 111 (01): : 182 - &
  • [35] REAL-TIME, IN-VIVO MEASUREMENT OF RADIATION-DOSE DURING RADIOIMMUNOTHERAPY IN MICE USING A MINIATURE MOSFET DOSIMETER PROBE
    GLADSTONE, DJ
    CHIN, LM
    RADIATION RESEARCH, 1995, 141 (03) : 330 - 335
  • [36] The effect of gel homogeneity on dose response in a low-density polymer gel dosimeter for radiation therapy
    Gholami, Mehrdad
    Shahbazi-Gahrouei, Daryoush
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2018, 14 (03) : 563 - 566
  • [37] RADIATION DOSE-RESPONSE CHARACTERISTICS OF LEUCOCYTE RECOVERY IN MOUSE
    SMITH, WW
    ALDERMAN, IM
    SCHNEIDER, CA
    CORNFIELD, J
    PROCEEDINGS OF THE SOCIETY FOR EXPERIMENTAL BIOLOGY AND MEDICINE, 1963, 113 (04): : 1016 - &
  • [38] Effects of Temporary Tachytherapy Inhibition Magnet On MOSFET Dose Measurements of Cardiovascular Implantable Electronic Devices (CIED) in Radiation Therapy Patients
    Joshi, C. P.
    Salomons, G.
    Peters, C.
    Lalonde, M.
    Kerr, A.
    MEDICAL PHYSICS, 2014, 41 (06) : 256 - 256
  • [39] Dose response of radiation-induced low-dose film dosimeter of inorganic salt and red cresol dye blended PVA
    Abd Rani, Sofiah
    Mustafa, Iskandar Shahrim
    Rahman, Azhar Abdul
    Khalib, Nuridayanti Che
    MATERIALS TODAY-PROCEEDINGS, 2022, 66 : 3977 - 3980
  • [40] Radiation dose response of N channel MOSFET submitted to filtered X-ray photon beam
    Goncalves Filho, Luiz C.
    Monte, David S.
    Barros, Fabio R.
    Santos, Luiz A. P.
    ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA 2017), 2018, 170