Quality assessment of the optical thin films using line field spectral domain optical coherence tomography

被引:12
|
作者
Shirazi, Muhammad Faizan [1 ,3 ]
Wijesinghe, Ruchire Eranga [2 ,3 ]
Ravichandran, Naresh Kumar [3 ]
Kim, Pilun [4 ]
Jeon, Mansik [3 ]
Kim, Jeehyun [3 ]
机构
[1] Med Univ Vienna, Ctr Med Phys & Biomed Engn, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Kyungil Univ, Coll Engn, Dept Biomed Engn, 50 Gamasil Gil, Gyongsan 38428, Gyeongsangbuk D, South Korea
[3] Kyungpook Natl Univ, Coll IT Engn, Sch Elect Engn, 80 Daehak Ro, Daegu 41566, South Korea
[4] Kyungpook Natl Univ, Inst Biomed Engn, 80 Daehak Ro, Daegu 41566, South Korea
关键词
Automatic industrial inspection; High resolution imaging; Optical coherence tomography; Optical imaging; Thin films; NONDESTRUCTIVE INSPECTION; HUMAN EYE; GLASS; OCT; MICROSCOPY; COMPOSITE; RANGE; MODE;
D O I
10.1016/j.optlaseng.2018.05.013
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this study, the industrial inspection of optical thin film on touch screen panels was demonstrated using line field spectral domain optical coherence tomography. The conventional Fourier domain optical coherence tomography system requires a single scanner for two-dimensional cross-sectional images and two scanners for volumetric images. Our developed line field spectral domain optical coherence tomography has the advantage of needing only a single scanner for volumetric images, while two-dimensional cross-sectional images are obtained by the parallel acquisition of an illuminated line on a sample using an area camera. Further, the image acquisition speed was enhanced by implementing a high speed camera (340 frames per seconds) with improved quantum efficiency at near infrared region enabling two-fold frame rate. Cross-sectional and volumetric images were acquired to detect the internal sublayer defects in the optical thin films, which are difficult to observe using visual or machine vision-based inspection methods. The developed pseudo code for defect identification in optical thin films was well-utilized here for the defect inspection. The system characterization is demonstrated using United State Air Force (USAF) resolution target. The results indicate the possible application of the proposed system in touch screen panel inspection for the quality assurance of products at the consumer end.
引用
收藏
页码:47 / 53
页数:7
相关论文
共 50 条
  • [11] Line Field Optical Coherence Tomography
    Lawman, Samuel
    Zhang, Zijian
    Shen, Yao-Chun
    Zheng, Yalin
    PHOTONICS, 2022, 9 (12)
  • [12] WIDE-FIELD SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY
    Gilardoni, Francesca
    Pichi, Francesco
    Bonsignore, Francesco
    Nucci, Paolo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [13] Imaging quality enhancement by deconvolution in spectral domain optical coherence tomography
    Wang Kai
    Zeng Yan
    Ding Zhi-Hua
    Meng Jie
    Shi Guo-Hua
    Zhang Yu-Dong
    ACTA PHYSICA SINICA, 2010, 59 (04) : 2471 - 2478
  • [14] Multirate Spectral Domain Optical Coherence Tomography
    Gaur, Prabhav
    Grieco, Andrew
    Fainman, Yeshaiahu
    IEEE PHOTONICS JOURNAL, 2023, 15 (05):
  • [15] Spectral domain optical coherence tomography interpretation
    Blacklaws, Jake
    Seamone, Mark E.
    Gupta, R. Rishi
    BRITISH JOURNAL OF HAEMATOLOGY, 2018, 181 (05) : 710 - 710
  • [16] Spectral domain optical coherence tomography with balanced detection using single line-scan camera and optical delay line
    Hyeon, Min Gyu
    Kim, Hyung-Jin
    Kim, Beop-Min
    Eom, Tae Joong
    OPTICS EXPRESS, 2015, 23 (18): : 23079 - 23091
  • [17] Methodology for Assessment of Structural Vibrations by Spectral Domain Optical Coherence Tomography
    Gao, Simon S.
    Raphael, Patrick
    Xia, Anping
    Park, Jesung
    Carbajal, Esteban
    Applegate, Brian E.
    Oghalai, John S.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS VIII, PTS 1 AND 2, 2012, 8207
  • [18] Comparison of 55° Wide-Field Spectral Domain Optical Coherence Tomography and Conventional 30° Optical Coherence Tomography for the Assessment of Diabetic Macular Edema
    Munk, Marion R.
    Lincke, Joel
    Giannakaki-Zimmermann, Helena
    Ebneter, Andreas
    Wolf, Sebastian
    Zinkernagel, Martin S.
    OPHTHALMOLOGICA, 2017, 237 (03) : 145 - 152
  • [19] Standard and line-field Fourier domain optical coherence tomography
    Yasuno, Yoshiaki
    Makita, Shuichi
    Endo, Takashi
    Aoki, Gouki
    Nakamura, Yoshifumi
    Yamanari, Masahiro
    Itoh, Masahide
    Yatagai, Toyohiko
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 7224 - 7226
  • [20] Line-field Fourier-domain optical coherence tomography
    Endo, T
    Yasuno, Y
    Truffer, F
    Aoki, G
    Makita, S
    Itoh, M
    Yatagai, T
    Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine IX, 2005, 5690 : 168 - 173