Measurement of formaldehyde in a single puff of cigarette smoke using tunable diode laser infrared spectroscopy

被引:40
|
作者
Parrish, ME [1 ]
Harward, CN [1 ]
机构
[1] Philip Morris USA, RD&E, Richmond, VA 23261 USA
关键词
TDL infrared spectroscopy; formaldehyde; cigarette smoke; tobacco smoke;
D O I
10.1366/0003702001948709
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A mettled has been developed for measuring formaldehyde in single puffs of mainstream (MS) and per cigarette in sidestream (SS) smoke with the use of tunable diode laser (TDL) infrared spectroscopy, Thirty to fifty percent of the total MS formaldehyde delivery per cigarette is generated in the lighting puff. This phenomenon is unique to formaldehyde compared to most other gaseous smoke components. The effect of the lighting technique, parking density of the tobacco in the cigarette rod, flow rate of air (heating rate) through the cigarette coal (burning zone), and tobacco type on the formaldehyde levels were studied. Calibration was based on measuring the second-derivative spectral response of formaldehyde generated from certified paraformaldehyde permeation tubes. The accuracy of the measured value of this standard was determined to be within +/-0.7% of the certified formaldehyde delivery by performing periodic gravimetric measurements. In addition, the formaldehyde standard was collected in a water trap and analyzed by using a colorimetric analytical technique, providing an agreement of +/-2% with the TDL measurement, The TDL method precision was less than or equal to1% with the use of the permeation standard. The MS formaldehyde deliveries for a Philip Morris monitor and Kentucky Reference 1R4F cigarette were 37 +/- 5 and 27 +/- 5 mug/cigt., respectively. The 1R4F value was in close agreement with results found by using an HPLC method reported in the literature. The MS sampling system can be quickly modified to determine formaldehyde levels in sidestream smoke. The SS formaldehyde delivery for the Philip Morris monitor cigarette was 2.1 +/- 0.1 mg/cigt. (i.e., 0.27 +/- 0.01 mg/min). The range of SS deliveries for reference, experimental, and commercial brands was much less than that observed for the MS smoke deliveries of similar cigarettes.
引用
收藏
页码:1665 / 1677
页数:13
相关论文
共 50 条
  • [31] Measurement of middle infrared spectroscopic parameters of carbon disulfide based on tunable diode laser absorption spectroscopy
    Guan Lin-Qiang
    Deng Hao
    Yao Lu
    Nie Wei
    Xu Zhen-Yu
    Li Xiang
    Zang Yi-Peng
    Hu Mai
    Fan Xue-Li
    Yang Chen-Guang
    Kan Rui-Feng
    ACTA PHYSICA SINICA, 2019, 68 (08)
  • [32] Simultaneous measurement of liquid water film thickness and vapor temperature using near-infrared tunable diode laser spectroscopy
    Yang, H.
    Greszik, D.
    Dreier, T.
    Schulz, C.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2010, 99 (03): : 385 - 390
  • [33] Highly sensitive measurement of trace methane gas using mid-infrared tunable diode laser absorption spectroscopy method
    Huang, Yong
    Fu, Wei
    Yang, Shang
    Li, Chunguang
    Hu, Xiewen
    Zhang, Mengru
    Chen, Chen
    Chang, Shuaipeng
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2024, 66 (01)
  • [34] Simultaneous measurement of liquid water film thickness and vapor temperature using near-infrared tunable diode laser spectroscopy
    H. Yang
    D. Greszik
    T. Dreier
    C. Schulz
    Applied Physics B, 2010, 99 : 385 - 390
  • [35] Methanogenic activity tests by Infrared Tunable Diode Laser Absorption Spectroscopy
    Martinez-Cruz, Karla
    Sepulveda-Jauregui, Armando
    Escobar-Orozco, Nayeli
    Thalasso, Frederic
    JOURNAL OF MICROBIOLOGICAL METHODS, 2012, 91 (01) : 89 - 92
  • [36] Airborne tunable diode laser measurements of formaldehyde
    Fried, A
    Wert, BP
    Henry, B
    Drummond, JR
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1999, 55 (10) : 2097 - 2110
  • [37] Evaluation of hydrazine acetate filters using in reduction by cellulose infrared tunable diode laser spectroscopy
    Harward, CN
    Parrish, ME
    Plunkett, SE
    Banyasz, JL
    Shafer, KH
    ANALYTICAL CHEMISTRY, 2002, 74 (22) : 5871 - 5881
  • [38] Measurements of formaldehyde by tunable diode laser spectroscopy and the enzymatic fluorometric method: An intercomparison study
    Mucke, R
    Scheumann, B
    Slemr, J
    Slemr, F
    Werle, P
    INFRARED PHYSICS & TECHNOLOGY, 1996, 37 (01) : 29 - 32
  • [39] Time-resolved analysis of cigarette combustion gases using a dual infrared tunable diode laser system
    Plunkett, S
    Parrish, ME
    Shafer, KH
    Nelson, D
    Shorter, J
    Zahniser, M
    VIBRATIONAL SPECTROSCOPY, 2001, 27 (01) : 53 - 63
  • [40] Measurement on gas temperature distribution by tunable diode laser absorption spectroscopy
    State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027, China
    Guang Pu Xue Yu Guang Pu Fen Xi, 2008, 8 (1708-1712):