Measurement of formaldehyde in a single puff of cigarette smoke using tunable diode laser infrared spectroscopy

被引:40
|
作者
Parrish, ME [1 ]
Harward, CN [1 ]
机构
[1] Philip Morris USA, RD&E, Richmond, VA 23261 USA
关键词
TDL infrared spectroscopy; formaldehyde; cigarette smoke; tobacco smoke;
D O I
10.1366/0003702001948709
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A mettled has been developed for measuring formaldehyde in single puffs of mainstream (MS) and per cigarette in sidestream (SS) smoke with the use of tunable diode laser (TDL) infrared spectroscopy, Thirty to fifty percent of the total MS formaldehyde delivery per cigarette is generated in the lighting puff. This phenomenon is unique to formaldehyde compared to most other gaseous smoke components. The effect of the lighting technique, parking density of the tobacco in the cigarette rod, flow rate of air (heating rate) through the cigarette coal (burning zone), and tobacco type on the formaldehyde levels were studied. Calibration was based on measuring the second-derivative spectral response of formaldehyde generated from certified paraformaldehyde permeation tubes. The accuracy of the measured value of this standard was determined to be within +/-0.7% of the certified formaldehyde delivery by performing periodic gravimetric measurements. In addition, the formaldehyde standard was collected in a water trap and analyzed by using a colorimetric analytical technique, providing an agreement of +/-2% with the TDL measurement, The TDL method precision was less than or equal to1% with the use of the permeation standard. The MS formaldehyde deliveries for a Philip Morris monitor and Kentucky Reference 1R4F cigarette were 37 +/- 5 and 27 +/- 5 mug/cigt., respectively. The 1R4F value was in close agreement with results found by using an HPLC method reported in the literature. The MS sampling system can be quickly modified to determine formaldehyde levels in sidestream smoke. The SS formaldehyde delivery for the Philip Morris monitor cigarette was 2.1 +/- 0.1 mg/cigt. (i.e., 0.27 +/- 0.01 mg/min). The range of SS deliveries for reference, experimental, and commercial brands was much less than that observed for the MS smoke deliveries of similar cigarettes.
引用
收藏
页码:1665 / 1677
页数:13
相关论文
共 50 条
  • [21] MEASUREMENT OF TRACE GAS FLUXES USING TUNABLE DIODE-LASER SPECTROSCOPY
    ZAHNISER, MS
    NELSON, DD
    MCMANUS, JB
    KEBABIAN, PL
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1995, 351 (1696): : 371 - 381
  • [22] Transient gas viscosity measurement using tunable diode laser absorption spectroscopy
    Rongkang Gao
    Sean O’Byrne
    Suzanne L. Sheehe
    Joseph Kurtz
    Jong-Leng Liow
    Experiments in Fluids, 2017, 58
  • [23] Transient gas viscosity measurement using tunable diode laser absorption spectroscopy
    Gao, Rongkang
    O'Byrne, Sean
    Sheehe, Suzanne L.
    Kurtz, Joseph
    Liow, Jong-Leng
    EXPERIMENTS IN FLUIDS, 2017, 58 (11)
  • [24] HIGH-RESOLUTION INFRARED SPECTROSCOPY WITH A TUNABLE DIODE LASER
    HINKLEY, ED
    APPLIED PHYSICS LETTERS, 1970, 16 (09) : 351 - &
  • [25] TUNABLE DIODE-LASER MEASUREMENT OF HYDROGEN-CYANIDE IN SMOKE
    FORREST, G
    VILCINS, G
    APPLIED SPECTROSCOPY, 1980, 34 (04) : 418 - 419
  • [26] Measurement of Oxygen concentration using tunable diode laser absorption spectroscopy and wavelength modulation spectroscopy
    State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
    Zhongguo Jiguang, 2008, 10 (1558-1562):
  • [27] SURFACE INFRARED REFLECTION ABSORPTION-SPECTROSCOPY USING A TUNABLE DIODE-LASER
    BUTLER, JE
    BERMUDEZ, VM
    HYLDEN, JL
    SURFACE SCIENCE, 1985, 163 (2-3) : L708 - L719
  • [28] MEASUREMENTS OF FORMALDEHYDE IN THE TROPOSPHERE BY TUNABLE DIODE-LASER ABSORPTION-SPECTROSCOPY
    HARRIS, GW
    MACKAY, GI
    IGUCHI, T
    MAYNE, LK
    SCHIFF, HI
    JOURNAL OF ATMOSPHERIC CHEMISTRY, 1989, 8 (02) : 119 - 137
  • [29] Optimization for hydrogen gas quantitative measurement using tunable diode laser absorption spectroscopy
    Xiafukaiti, Alifu
    Lagrosas, Nofel
    Ogita, Masakazu
    Oi, Nobuhiko
    Ichikawa, Yuji
    Sugimoto, Sachiyo
    Asahi, Ippei
    Yamaguchi, Shigeru
    Shiina, Tatsuo
    OPTICS AND LASER TECHNOLOGY, 2025, 180
  • [30] MEASUREMENT OF TRACE GAS FLUXES USING TUNABLE DIODE-LASER SPECTROSCOPY - DISCUSSION
    LLOYD, D
    ZAHNISER, MS
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1995, 351 (1696): : 381 - 382