Analysis of fracture failure of diaphragm of Non-contact electronic horn

被引:1
|
作者
Jiang, Shu Yong [1 ]
Zhang, Yan Qiu [1 ]
Sun, Jin Feng [2 ]
Zhao, Li Hong [1 ]
机构
[1] Harbin Engn Univ, Engn Training Ctr, Harbin 150001, Heilongjiang, Peoples R China
[2] Harbin Engn Univ, Coll Mat Sci & Chem Engn, Harbin 150001, Peoples R China
关键词
Diaphragm; Fracture; FEM; Metal forming;
D O I
10.4028/www.scientific.net/AMR.97-101.514
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The fracture of the diaphragm is the main failure pattern of the non-contact electronic horn. The spring steel strip 50CrVA which is cold rolled was applied to manufacture the diaphragm of the non-contact electronic horn by means of sheet metal forming. The combination of the experiments with finite element method (FEM) was used to reveal mechanism of fracture failure of the diaphragm. The displacement field, the effective strain field and the effective stress field at the maximum amplitude value are obtained by simulating the genuine vibrating state of the diaphragm with the help of ANSYS finite element code. The maximum stress zone of the stress field of the diaphragm is responsible for the fracture zone of the diaphragm. The fatigue test of the diaphragm and microscopy of the fractured diaphragm indicates that the fracture pattern of the diaphragm agree well with finite element simulation results. Eventually, the measures to prevent the fracture of the diaphragm were taken in order to increase the endurance of the diaphragm.
引用
下载
收藏
页码:514 / +
页数:2
相关论文
共 50 条
  • [41] NON-CONTACT SPEED MEASUREMENT
    KENYON, M
    VANHOEK, HC
    PORTER, CA
    AUSTRALIAN JOURNAL OF INSTRUMENTATION & CONTROL, 1981, 37 (06): : 114 - 117
  • [42] Non-contact stiffness imager
    Kawahara, Tomohiro
    Tanaka, Shinji
    Kaneko, Makoto
    INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2006, 25 (5-6): : 537 - 549
  • [43] PROGRESS IN NON-CONTACT MEASUREMENT
    LEWIS, GE
    CME-CHARTERED MECHANICAL ENGINEER, 1981, 28 (08): : 31 - 32
  • [44] Contact and non-contact compound thermometry transducer
    Yi Qi Yi Biao Xue Bao, 5 (470-474):
  • [45] Non-contact ECG monitoring
    Brydon, J
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2002, 13 (04) : 641 - 641
  • [46] Non-contact AFM PREFACE
    Giessibl, Franz J.
    Morita, Seizo
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2012, 24 (08)
  • [47] Overdamped non-contact rectifiers
    Moradian, A.
    Alvand, M.
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2018, 32 (20):
  • [48] AO - NON-CONTACT TONOMETER
    SORENSEN, PN
    ACTA OPHTHALMOLOGICA, 1975, : 32 - 33
  • [49] Non-contact temperature measurement
    不详
    INDUSTRIAL CERAMICS, 2001, 21 (01): : 56 - 56
  • [50] NON-CONTACT TONOMETRY BY ASSISTANTS
    SAGAN, W
    SCHWADERER, K
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1975, 52 (04): : 288 - 290