Analysis of fracture failure of diaphragm of Non-contact electronic horn

被引:1
|
作者
Jiang, Shu Yong [1 ]
Zhang, Yan Qiu [1 ]
Sun, Jin Feng [2 ]
Zhao, Li Hong [1 ]
机构
[1] Harbin Engn Univ, Engn Training Ctr, Harbin 150001, Heilongjiang, Peoples R China
[2] Harbin Engn Univ, Coll Mat Sci & Chem Engn, Harbin 150001, Peoples R China
关键词
Diaphragm; Fracture; FEM; Metal forming;
D O I
10.4028/www.scientific.net/AMR.97-101.514
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The fracture of the diaphragm is the main failure pattern of the non-contact electronic horn. The spring steel strip 50CrVA which is cold rolled was applied to manufacture the diaphragm of the non-contact electronic horn by means of sheet metal forming. The combination of the experiments with finite element method (FEM) was used to reveal mechanism of fracture failure of the diaphragm. The displacement field, the effective strain field and the effective stress field at the maximum amplitude value are obtained by simulating the genuine vibrating state of the diaphragm with the help of ANSYS finite element code. The maximum stress zone of the stress field of the diaphragm is responsible for the fracture zone of the diaphragm. The fatigue test of the diaphragm and microscopy of the fractured diaphragm indicates that the fracture pattern of the diaphragm agree well with finite element simulation results. Eventually, the measures to prevent the fracture of the diaphragm were taken in order to increase the endurance of the diaphragm.
引用
下载
收藏
页码:514 / +
页数:2
相关论文
共 50 条
  • [21] Non-contact measurement of contact wire
    Yi Yaxing
    Ye Xuemei
    Li Zhongke
    Yue Kaiduan
    2008 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND APPLICATIONS, 2009, 7160
  • [22] A framework for non-contact measurement and analysis of NURBS surfaces
    M. Ristic
    D. Brujic
    The International Journal of Advanced Manufacturing Technology, 1998, 14 : 210 - 219
  • [23] Analysis of migration processes by non-contact photopyroelectric method
    Antoniow, JS
    Henry, JF
    Chirtoc, M
    Paris, D
    Potron, G
    PHOTOACOUSTIC AND PHOTOTHERMAL PHENOMENA: TENTH INTERNATIONAL CONFERENCE, 1999, 463 : 567 - 569
  • [24] Non-contact method of search and analysis of pulsating vessels
    Avtomonov, Yuri N.
    Tsoy, Maria O.
    Postnov, Dmitry E.
    SARATOV FALL MEETING 2017: LASER PHYSICS AND PHOTONICS XVIII; AND COMPUTATIONAL BIOPHYSICS AND ANALYSIS OF BIOMEDICAL DATA IV, 2018, 10717
  • [25] A framework for non-contact measurement and analysis of NURBS surfaces
    Ristic, M
    Brujic, D
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 1998, 14 (03): : 210 - 219
  • [26] Hyperspectral imaging for non-contact analysis of forensic traces
    Edelman, G. J.
    Gaston, E.
    van Leeuwen, T. G.
    Cullen, P. J.
    Aalders, M. C. G.
    FORENSIC SCIENCE INTERNATIONAL, 2012, 223 (1-3) : 28 - 39
  • [27] Hybrid electronic skin combining triboelectric nanogenerator and humidity sensor for contact and non-contact sensing
    Yin, Feifei
    Guo, Yunjian
    Qiu, Zhicheng
    Niu, Hongsen
    Wang, Wenxiao
    Li, Yang
    Kim, Eun Seong
    Kim, Nam Young
    NANO ENERGY, 2022, 101
  • [28] Non-contact mapping in cardiac electrophysiology; [„Non-contact mapping“ in der kardialen Elektrophysiologie]
    Wieczorek M.
    Herzschrittmachertherapie + Elektrophysiologie, 2018, 29 (3) : 264 - 270
  • [29] Comparative analysis of dental trauma in contact and non-contact sports: A systematic review
    de Lima, Luiz Gustavo Healt
    dos Santos, Caroline Souza
    Rocha, Juliana Schaia
    Tanaka, Orlando
    Rosa, Edvaldo Antonio Ribeiro
    Gasparello, Gil Guilherme
    DENTAL TRAUMATOLOGY, 2024,
  • [30] Accessibility analysis for the automatic contact and non-contact inspection on Coordinate Measuring Machines
    Alvarez, B. J.
    Fernandez, P.
    Rico, J. C.
    Valino, G.
    WORLD CONGRESS ON ENGINEERING 2008, VOLS I-II, 2008, : 117 - 122