Amperometric immunosensor for ricin by using on graphite and carbon nanotube paste electrodes

被引:33
|
作者
Suresh, S. [1 ]
Gupta, A. K. [1 ]
Rao, V. K. [1 ]
Kumar, Om [1 ]
Vijayaraghavan, R. [1 ]
机构
[1] Def Res & Dev Estab, BD Div, Gwalior 474002, Madhya Pradesh, India
关键词
Ricin; Multiwalled carbon nanotube; Carbon paste electrodes; Amperometry; Immunosensor; ELISA; ELECTROCHEMICAL IMMUNOASSAY; SALMONELLA-TYPHI; PURIFICATION; ROUTE; ASSAY;
D O I
10.1016/j.talanta.2010.01.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ricin is a scheduled chemical warfare agent and biological warfare agent. Attempts were made for the detection of ricin in water samples by utilizing amperometric immunosensors. These electrodes were made by mixing Paraffin oil with graphite powder and multiwalled carbon nanotubes. The graphite paste electrode (CPE) and multiwalled carbon nanotubes paste electrode (MWCNTPE) were tested for their ability to detect 1-naphthol. A sandwich enzyme linked immunosorbent assay system was used to detect ricin. The detection limit for both electrodes was compared. It was found that the response of amperometric sensor is proportional to the ricin concentration in both the cases and is linear in the range 0.625-25 ng/ml for MWCNTPE and 2.5-25 ng/ml for CPE. The SEM showed that the MWCNTPE has revealed crevices/voids in which the antibodies may get trapped. Spectroscopic experiments proved that MWCNTPE adsorbs antibodies better than CPE. The high sensitivity of MWCNTPE was attributed to its better electrochemical properties rather than to its efficiency to adsorb antibodies. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:703 / 708
页数:6
相关论文
共 50 条
  • [21] Utilization of Carbon Paste Electrodes for Amperometric Detection in HPLC with Gradient Elution
    Dejmkova, Hana
    Fahnrichova, Barbora
    Barek, Jiri
    Zima, Jiri
    [J]. XXXIII MODERNI ELEKTROCHEMICKE METODY, 2013, : 37 - 39
  • [22] Single-wall carbon nanotube paste electrodes: a comparison with carbon paste, platinum and glassy carbon electrodes via cyclic voltammetric data
    Antiochia, R
    Lavagnini, I
    Magno, F
    Valentini, T
    Palleschi, G
    [J]. ELECTROANALYSIS, 2004, 16 (17) : 1451 - 1458
  • [23] Carbon nanotubes, Conductive Carbon Black and Graphite Powder Based Paste Electrodes
    Zhang, Xuzhi
    Cui, Yi
    Lv, Zhilin
    Li, Meng
    Ma, Shaosai
    Cui, Zhengguo
    Kong, Qing
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (12): : 6063 - 6073
  • [24] AMPEROMETRIC DETERMINATION OF OZONE IN WATER AT DISPOSABLE GRAPHITE REINFORCEMENT CARBON ELECTRODES
    AOKI, K
    KOBAYASHI, A
    KATO, N
    [J]. ELECTROANALYSIS, 1990, 2 (01) : 31 - 34
  • [25] Electrochemical Amperometric Biosensors Based on Directly Synthesized Carbon Nanotube Electrodes
    Maehashi, Kenzo
    Matsumoto, Kazuhiko
    [J]. SENSORS AND MATERIALS, 2009, 21 (07) : 363 - 372
  • [26] ELECTROCATALYSIS AND AMPEROMETRIC DETECTION OF ORGANIC PEROXIDES AT MODIFIED CARBON-PASTE ELECTRODES
    WANG, J
    ANGNES, L
    LIANG, C
    EVANS, O
    [J]. TALANTA, 1991, 38 (10) : 1077 - 1081
  • [27] Formate dehydrogenase-modified carbon paste electrodes for amperometric detection of formate
    Munteanu, Florentina-Dainela
    Gligor, Delia
    Popescu, Ionel Catalin
    Gorton, Lo
    [J]. REVUE ROUMAINE DE CHIMIE, 2006, 51 (01) : 25 - 30
  • [28] AMPEROMETRIC CARBON PASTE ENZYME ELECTRODES FOR URIC ACID DETERMINATION WITH DIFFERENT MEDIATORS
    Erden, Pinar Esra
    Pekyardimci, Sule
    Kilic, Esma
    [J]. COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 2011, 76 (09) : 1055 - 1073
  • [29] Determination of Riboflavin at Carbon Nanotube Paste Electrodes Modified with an Anionic Surfactant
    Tigari, Girish
    Manjunatha, Jamballi G.
    Raril, Chenthatill
    Hareesha, Nagarajappa
    [J]. CHEMISTRYSELECT, 2019, 4 (07): : 2168 - 2173
  • [30] Carbon nanotubes paste versus graphite working electrodes in electrochemical analysis
    Prasek, J.
    Hubalek, J.
    Adamek, M.
    Kizek, R.
    [J]. 2006 IEEE SENSORS, VOLS 1-3, 2006, : 1261 - +