Utilization of Carbon Paste Electrodes for Amperometric Detection in HPLC with Gradient Elution

被引:0
|
作者
Dejmkova, Hana [1 ]
Fahnrichova, Barbora [1 ]
Barek, Jiri [1 ]
Zima, Jiri [1 ]
机构
[1] Charles Univ Prague, Fac Sci, Dept Analyt Chem, UNESCO Lab Environm Electrochem, CZ-12843 Prague 2, Czech Republic
关键词
Glassy carbon paste electrode; Benzophenone; HPLC; Gradient elution;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Method for the determination of benzophenone-1 and benzophenone-3 was developed, using HPLC with amperometric detection on glassy carbon paste electrode. Due to the utilization of gradient elution including high content of methanol, attention was paid to the stability of the electrode material and to the influence of these conditions on the determination parameters. Key words: Glassy carbon paste electrode, Benzophenone, HPLC, Gradient elution.
引用
收藏
页码:37 / 39
页数:3
相关论文
共 50 条
  • [1] Amperometric determination of rutin on carbon paste electrodes
    Macikova, Pavla
    Hrbac, Jan
    Halouzka, Vladimir
    Skopalova, Jana
    [J]. JOURNAL OF BIOCHEMICAL TECHNOLOGY, 2010, 2 (05) : S20 - S21
  • [2] AMPEROMETRIC DETERMINATION OF RUTIN ON CARBON PASTE ELECTRODES
    Macikova, Pavla
    Hrbac, Jan
    Halouzka, Vladimir
    Skopalova, Jana
    [J]. X PRACOVNI SETKANI FYZIKALNICH CHEMIKU A ELECTROCHEMIKU/ 10TH WORKSHOP OF PHYSICAL CHEMISTS AND ELECTROCHEMISTS, 2010, : 147 - 149
  • [3] Effects of mediator and paste hydrophobicity on the response of amperometric carbon paste electrodes: Binder paste electrodes
    Narvaez, A
    Parellada, J
    Dominguez, E
    Katakis, I
    [J]. QUIMICA ANALITICA, 1996, 15 (01): : 75 - 82
  • [4] ELECTROCATALYSIS AND AMPEROMETRIC DETECTION OF ORGANIC PEROXIDES AT MODIFIED CARBON-PASTE ELECTRODES
    WANG, J
    ANGNES, L
    LIANG, C
    EVANS, O
    [J]. TALANTA, 1991, 38 (10) : 1077 - 1081
  • [5] Amperometric detection of glucose using self-catalytic carbon paste electrodes
    Evans, RG
    Banks, CE
    Compton, RG
    [J]. ANALYST, 2004, 129 (05) : 428 - 431
  • [6] Formate dehydrogenase-modified carbon paste electrodes for amperometric detection of formate
    Munteanu, Florentina-Dainela
    Gligor, Delia
    Popescu, Ionel Catalin
    Gorton, Lo
    [J]. REVUE ROUMAINE DE CHIMIE, 2006, 51 (01) : 25 - 30
  • [7] Determination of Benzocaine Using HPLC and FIA with Amperometric Detection on a Carbon Paste Electrode
    Dejmkova, Hana
    Vokalova, Veronika
    Zima, Jiri
    Barek, Jiri
    [J]. ELECTROANALYSIS, 2011, 23 (03) : 662 - 666
  • [8] IMMOBILIZED ENZYME CARBON PASTE ELECTRODES AS AMPEROMETRIC SENSORS
    LORENZO, E
    GONZALEZ, E
    PARIENTE, F
    HERNANDEZ, L
    [J]. ELECTROANALYSIS, 1991, 3 (4-5) : 319 - 323
  • [9] HPLC OF TRIGLYCERIDES WITH GRADIENT ELUTION AND MASS DETECTION
    HERSLOF, B
    KINDMARK, G
    [J]. LIPIDS, 1985, 20 (11) : 783 - 790
  • [10] Amperometric detection of phenolic compounds by polypyrrole-based composite carbon paste electrodes
    Mailley, P
    Cummings, EA
    Mailley, S
    Cosnier, S
    Eggins, BR
    McAdams, E