Utilization of Carbon Paste Electrodes for Amperometric Detection in HPLC with Gradient Elution

被引:0
|
作者
Dejmkova, Hana [1 ]
Fahnrichova, Barbora [1 ]
Barek, Jiri [1 ]
Zima, Jiri [1 ]
机构
[1] Charles Univ Prague, Fac Sci, Dept Analyt Chem, UNESCO Lab Environm Electrochem, CZ-12843 Prague 2, Czech Republic
关键词
Glassy carbon paste electrode; Benzophenone; HPLC; Gradient elution;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Method for the determination of benzophenone-1 and benzophenone-3 was developed, using HPLC with amperometric detection on glassy carbon paste electrode. Due to the utilization of gradient elution including high content of methanol, attention was paid to the stability of the electrode material and to the influence of these conditions on the determination parameters. Key words: Glassy carbon paste electrode, Benzophenone, HPLC, Gradient elution.
引用
收藏
页码:37 / 39
页数:3
相关论文
共 50 条
  • [11] AMPEROMETRIC BIOSENSORS FOR GLUCOSE BASED ON CARBON PASTE MODIFIED ELECTRODES
    AMINE, A
    KAUFFMANN, JM
    PATRIARCHE, GJ
    [J]. TALANTA, 1991, 38 (01) : 107 - 110
  • [12] VOLTAMMETRIC AND AMPEROMETRIC DETERMINATION OF DOXORUBICIN USING CARBON PASTE ELECTRODES
    Jemelkova, Zuzana
    Zima, Jiri
    Barek, Jiri
    [J]. COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 2009, 74 (10) : 1503 - 1515
  • [13] Carbon paste electrodes incorporating synthetic zeolites and methylene blue for amperometric detection of ascorbic acid
    Varodi, Codruta
    Gligor, Delia
    Muresan, Liana M.
    [J]. STUDIA UNIVERSITATIS BABES-BOLYAI CHEMIA, 2007, 52 (01): : 109 - 117
  • [14] SELECTIVE AMPEROMETRIC DETECTION IN HPLC WITH ANODIC COPPER ELECTRODES
    KOK, WT
    BRINKMAN, UAT
    FREI, RW
    [J]. PHARMACEUTISCH WEEKBLAD-SCIENTIFIC EDITION, 1983, 5 (06) : 339 - 339
  • [15] HPLC determination of naphthalene amino derivatives using electrochemical detection at carbon paste electrodes
    Zima, Jiri
    Dejmkova, Hana
    Barek, Jiri
    [J]. ELECTROANALYSIS, 2007, 19 (2-3) : 185 - 190
  • [16] Amperometric cholinesterase biosensors with carbon paste electrodes modified with cobalt phthalocyanine
    Shaidarova, LG
    Ziganshina, SA
    Medyantseva, EP
    Budnikov, GK
    [J]. RUSSIAN JOURNAL OF APPLIED CHEMISTRY, 2004, 77 (02) : 241 - 248
  • [17] Amperometric Cholinesterase Biosensors with Carbon Paste Electrodes Modified with Cobalt Phthalocyanine
    L. G. Shaidarova
    S. A. Ziganshina
    E. P. Medyantseva
    G. K. Budnikov
    [J]. Russian Journal of Applied Chemistry, 2004, 77 : 241 - 248
  • [18] The effects of eluent mixing on TLS detection in gradient elution HPLC
    Logar, JK
    Sikovec, M
    Malej, A
    Franko, M
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (02) : 323 - 328
  • [19] Amperometric immunosensor for ricin by using on graphite and carbon nanotube paste electrodes
    Suresh, S.
    Gupta, A. K.
    Rao, V. K.
    Kumar, Om
    Vijayaraghavan, R.
    [J]. TALANTA, 2010, 81 (1-2) : 703 - 708
  • [20] Utilization of Carbon Paste Electrodes for the Voltammetric Determination of Chlortoluron
    Dejmkova, Hana
    Houskova, Lucie
    Barek, Jiri
    Zima, Jiri
    [J]. ELECTROANALYSIS, 2013, 25 (06) : 1529 - 1534