Preoperative assessment of implantable cochlea amplifiers using conventional X-ray and CT scans of the temporal bone

被引:0
|
作者
Maassen, MM [1 ]
Lehner, R [1 ]
Dammann, F [1 ]
Ludtke, R [1 ]
Zenner, HP [1 ]
机构
[1] Univ Tubingen, HNO Klin, D-72076 Tubingen, Germany
关键词
ear; hearing loss; TICA; hearing aid; mechanical transducer; X-ray; CT; cochlea amplifier implant;
D O I
10.1007/s001060050229
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Recently,the transducer and microphone of a cochlea amplifier implant (CAI) for the treatment of sensorineural cochlear hearing loss have been developed further for implantation into the mastoid cavity. At present, the University of Tuebingen implantable cochlea amplifier consists of an implantable microphone and an implantable piezoelectric transducer. It has been implanted into the first patients. Successful future application of this new implant depends on the suitable fit of the CAI within a patient's mastoid cavity. Using conventional X-ray and CT scans, we analyzed 50 cadaver specimens of the temporal bone before total mastoidectomy. After total mastoidectomy,the volume of the mastoid cavity was measured using CT scans and water volume determination. Finally,the CAI was implanted into those temporal bones that were large enough to house it. Our results demonstrate that the degree of pneumatization in the conventional Schuller X-ray is already a good parameter for preoperative evaluation.
引用
收藏
页码:220 / 227
页数:8
相关论文
共 50 条
  • [41] COVID-19 Diagnosis in Computerized Tomography (CT) and X-ray Scans Using Capsule Neural Network
    Akinyelu, Andronicus A.
    Bah, Bubacarr
    DIAGNOSTICS, 2023, 13 (08)
  • [42] Assessment of intraductal carcinoma in situ (DCIS) using grating-based X-ray phase-contrast CT at conventional X-ray sources: An experimental ex-vivo study
    Hellerhoff, Karin
    Birnbacher, Lorenz
    Sztrokay-Gaul, Aniko
    Grandl, Susanne
    Auweter, Sigrid
    Willner, Marian
    Marschner, Mathias
    Mayr, Doris
    Reiser, Maximilian F.
    Pfeiffer, Franz
    Herzen, Julia
    PLOS ONE, 2019, 14 (01):
  • [43] Quasimonochromatic x-ray computed tomography by the balanced filter method using a conventional x-ray source
    Saito, M
    MEDICAL PHYSICS, 2004, 31 (12) : 3436 - 3443
  • [44] X-ray monochromator for divergent beam radiography using conventional and laser produced X-ray sources
    Schnopper, HW
    Romaine, S
    Krol, A
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES AND OPTICS II, 2001, 4502 : 19 - 29
  • [45] Bone age assessment by dual-energy X-ray absorptiometry in children: an alternative for X-ray?
    Heppe, D. H. M.
    Taal, H. R.
    Ernst, G. D. S.
    Van den Akker, E. L. T.
    Lequin, M. M. H.
    Hokken-Koelega, A. C. S.
    Geelhoed, J. J. M.
    Jaddoe, V. W. V.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1010): : 114 - 120
  • [46] POSSIBILITIES AND LIMITATIONS OF SPECTROSCOPY IN THE ULTRASOFT X-RAY REGION USING THE CONTINUUM OF A CONVENTIONAL X-RAY TUBE
    GILBERG, E
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1984, 447 : 68 - 72
  • [47] Porosity and pore-size distribution of geomaterials from X-ray CT scans
    Shin, H.S.
    Kim, K.Y.
    Pande, G.N.
    Springer Series in Geomechanics and Geoengineering, 2013, : 177 - 186
  • [48] Refinement of clinical X-ray computed tomography (CT) scans containing metal implants
    Treece, Graham
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2017, 56 : 11 - 23
  • [49] Abundance and distribution of diamonds in eclogite revealed by volume visualization of CT X-ray scans
    Schulze, DJ
    Wiese, D
    Steude, J
    JOURNAL OF GEOLOGY, 1996, 104 (01): : 109 - 114
  • [50] Temporal X-ray Reconstruction using Temporal and Spectral Measurements at LCLS
    Florian Christie
    Alberto Andrea Lutman
    Yuantao Ding
    Zhirong Huang
    Vatsal A. Jhalani
    Jacek Krzywinski
    Timothy J. Maxwell
    Daniel Ratner
    Juliane Rönsch-Schulenburg
    Mathias Vogt
    Scientific Reports, 10