Preoperative assessment of implantable cochlea amplifiers using conventional X-ray and CT scans of the temporal bone

被引:0
|
作者
Maassen, MM [1 ]
Lehner, R [1 ]
Dammann, F [1 ]
Ludtke, R [1 ]
Zenner, HP [1 ]
机构
[1] Univ Tubingen, HNO Klin, D-72076 Tubingen, Germany
关键词
ear; hearing loss; TICA; hearing aid; mechanical transducer; X-ray; CT; cochlea amplifier implant;
D O I
10.1007/s001060050229
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Recently,the transducer and microphone of a cochlea amplifier implant (CAI) for the treatment of sensorineural cochlear hearing loss have been developed further for implantation into the mastoid cavity. At present, the University of Tuebingen implantable cochlea amplifier consists of an implantable microphone and an implantable piezoelectric transducer. It has been implanted into the first patients. Successful future application of this new implant depends on the suitable fit of the CAI within a patient's mastoid cavity. Using conventional X-ray and CT scans, we analyzed 50 cadaver specimens of the temporal bone before total mastoidectomy. After total mastoidectomy,the volume of the mastoid cavity was measured using CT scans and water volume determination. Finally,the CAI was implanted into those temporal bones that were large enough to house it. Our results demonstrate that the degree of pneumatization in the conventional Schuller X-ray is already a good parameter for preoperative evaluation.
引用
收藏
页码:220 / 227
页数:8
相关论文
共 50 条
  • [21] Trabecular Bone Analysis in CT and X-Ray Images of the Proximal Femur for the Assessment of Local Bone Quality
    Fritscher, Karl
    Gruenerbl, Agnes
    Haenni, Markus
    Suhm, Norbert
    Hengg, Clemens
    Schubert, Rainer
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (10) : 1560 - 1575
  • [22] COMPARATIVE IMAGING OF A LARYNGOCELE BY MR, CT AND CONVENTIONAL X-RAY
    VOGL, T
    SCHULER, M
    HAHN, D
    FUNK, W
    MEES, M
    DIGITALE BILDDIAGNOSTIK, 1986, 6 (02): : 64 - 66
  • [23] High definition X-ray microtomography using a conventional impact X-ray source
    Davis, GR
    Elliott, JC
    JOURNAL DE PHYSIQUE IV, 2003, 104 : 131 - 134
  • [24] Fabrication of x-ray absorption gratings via deep x-ray lithography using a conventional x-ray tube
    Pinzek, Simon
    Beckenbach, Thomas
    Viermetz, Manuel
    Meyer, Pascal
    Gustschin, Alex
    Andrejewski, Jana
    Gustschin, Nikolai
    Herzen, Julia
    Schulz, Joachim
    Pfeiffer, Franz
    JOURNAL OF MICRO-NANOPATTERNING MATERIALS AND METROLOGY-JM3, 2021, 20 (04):
  • [25] Deep learning for the detection of semantic features in tree X-ray CT scans
    Khazem, Salim
    Richard, Antoine
    Fix, Jeremy
    Pradalier, Cedric
    ARTIFICIAL INTELLIGENCE IN AGRICULTURE, 2023, 7 : 13 - 26
  • [26] SIMULTANEOUS EMISSION CT AND X-RAY TRANSMISSION CT USING COMPOSITE X-RAY AND GAMMA-RAY DETECTORS
    CLINTHORNE, NH
    ANTONUK, LE
    HUANG, W
    YORKSTON, J
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P100 - P101
  • [27] Temporal X-ray reconstruction using temporal and spectral measurements
    Christie, F.
    Ding, Y.
    Huang, Z.
    Jhalani, V. A.
    Krzywinski, J.
    Lutman, A. A.
    Maxwell, T. J.
    Ratner, D.
    Roensch-Schulenburg, J.
    Vogt, M.
    9TH INTERNATIONAL PARTICLE ACCELERATOR CONFERENCE (IPAC18), 2018, 1067
  • [28] Diagnosis of osteitis in angiology patients: Comparison of x-ray and bone scans.
    Gocke, C
    Gocke, P
    Kroger, K
    Thelen, MH
    Muller, RD
    Langer, R
    Rudofsky, G
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 169 (01): : 58 - 62
  • [29] X-RAY TOMOGRAPHY IN FRACTURES OF THE TEMPORAL BONE AND INJURIES OF THE OSSICULA
    FREY, KW
    THEOPOLD, HM
    LARYNGOLOGIE RHINOLOGIE OTOLOGIE VEREINIGT MIT MONATSSCHRIFT FUR OHRENHEILKUNDE, 1981, 60 (09): : 451 - 470
  • [30] Macroradiography using conventional radiographic X-ray equipment
    Davidson, RA
    Bowman, S
    BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (898): : 831 - 836