Monte Carlo (MC) Simulation of Total Skin Electron Therapy (TSET) with TOPAS and EGSnrc

被引:0
|
作者
Zhong, W. [1 ]
Ding, G. [2 ]
Ong, Y. [1 ]
Zhu, T. [1 ]
机构
[1] Univ Penn, Philadelphia, PA 19104 USA
[2] Vanderbilt Univ, 221 Kirkland Hall, Nashville, TN 37235 USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-IePD-TR
引用
收藏
页数:1
相关论文
共 50 条
  • [21] In vivo EBT radiochromic film dosimetry of electron beam for Total Skin Electron Therapy (TSET)
    Bufacchi, A.
    Carosi, A.
    Adorante, N.
    delle Canne, S.
    Malatesta, T.
    Capparella, R.
    Fragomeni, R.
    Bonanni, A.
    Leone, M.
    Marmiroli, L.
    Begnozzi, L.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2007, 23 (02): : 67 - 72
  • [22] Monte Carlo simulation of large electron fields at extended distances: Total skin electron treatment optimization
    Shokrani, P
    Elson, H
    [J]. MEDICAL PHYSICS, 2005, 32 (07) : 2424 - 2424
  • [23] RADIATION DOSE DELIVERY FOR TOTAL SKIN ELECTRON THERAPY (TSET) WITH LOW ENERGY ELECTRON BEAMS
    Krishnamurthy, K.
    Davis, C. A.
    Ravichandran, R.
    Sivakumar, S. S.
    Mohanti, B. K.
    [J]. JOURNAL OF MEDICAL PHYSICS, 2005, 30 (02) : 66 - 70
  • [24] Total skin electron therapy treatment verification:: Monte Carlo simulation and beam characteristics of large non-standard electron fields
    Pavón, EC
    Sánchez-Doblado, F
    Leal, A
    Capote, R
    Lagares, JI
    Perucha, M
    Arráns, R
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (17): : 2783 - 2796
  • [25] Monte Carlo Simulation for the Radixact™ Tomotherapy Linac Using EGSnrc
    Makrani, Danial Seifi
    Nedaei, Hassan Ali
    Geraily, Ghazale
    Khorami-Moghaddam, Alireza
    Banaee, Nooshin
    Jassim, Hussam
    [J]. JOURNAL OF MEDICAL PHYSICS, 2024, 49 (03) : 379 - 386
  • [26] Validation of total skin electron irradiation (TSEI) technique dosimetry data by Monte Carlo simulation
    Nevelsky, Alexander
    Borzov, Egor
    Daniel, Shahar
    Bar-Deroma, Raquel
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 418 - 429
  • [27] The proton therapy nozzles at Samsung Medical Center: A Monte Carlo simulation study using TOPAS
    Kwangzoo Chung
    Jinsung Kim
    Dae-Hyun Kim
    Sunghwan Ahn
    Youngyih Han
    [J]. Journal of the Korean Physical Society, 2015, 67 : 170 - 174
  • [28] The Proton Therapy Nozzles at Samsung Medical Center: A Monte Carlo Simulation Study using TOPAS
    Chung, Kwangzoo
    Kim, Jinsung
    Kim, Dae-Hyun
    Ahn, Sunghwan
    Han, Youngyih
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (01) : 170 - 174
  • [29] An Analysis of Cumulative Surface Dose Based on Cherenkov imaging of Total Skin Electron Therapy (TSET)
    Petroccia, Heather
    Miao, Tianshun
    Maity, Amit
    Ong, Yihong
    Zhu, Yihua
    Bruza, Petr
    Pogue, Brian W.
    Plastaras, John
    Zhu, Timothy C.
    [J]. OPTICAL METHODS FOR TUMOR TREATMENT AND DETECTION: MECHANISMS AND TECHNIQUES IN PHOTODYNAMIC THERAPY XXVIII, 2019, 10860
  • [30] Monte Carlo simulation of electron cones used in electron beam therapy
    Williams, T.
    Ebert, M.
    Keall, E.
    Haskard, D.
    [J]. Australasian Physical and Engineering Sciences in Medicine, 1998, 21 (03): : 112 - 119