Total skin electron therapy treatment verification:: Monte Carlo simulation and beam characteristics of large non-standard electron fields

被引:1
|
作者
Pavón, EC
Sánchez-Doblado, F
Leal, A
Capote, R
Lagares, JI
Perucha, M
Arráns, R
机构
[1] Univ Seville, Fac Med, Dept Fisiol Med & Biofis, E-41009 Seville, Spain
[2] Univ Seville, Hosp Virgen Macarena, Serv Radiofis, E-41009 Seville, Spain
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2003年 / 48卷 / 17期
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Total skin electron therapy (TSET) is a complex technique which requires nonstandard measurements and dosimetric procedures. This paper investigates an essential first step towards TSET Monte Carlo (MC) verification. The non-standard 6 MeV 40 x 40 cm(2) electron beam at a source to surface distance (SSD) of 100 cm as well as its horizontal projection behind a polymethylmethacrylate (PMMA) screen to SSD = 380 cm were evaluated. The EGS4 OMEGA-BEAM code package running on a Linux home made 47 PCs cluster was used for the MC simulations. Percentage depth-dose curves and profiles were calculated and measured experimentally for the 40 x 40 cm(2) field at both SSD = 100 cm and patient surface SSD = 380 cm. The output factor (OF) between the reference 40 x 40 cm(2) open field and its horizontal projection as TSET beam at SSD = 380 cm was also measured for comparison with MC results. The accuracy of the simulated beam was validated by the good agreement to within 2% between measured relative dose distributions, including the beam characteristic parameters (R-50, R-80, R-100, R-p, E-0) and the MC calculated results. The energy spectrum, fluence and angular distribution at different stages of the beam (at SSD 100 cm, at SSD = 364.2 cm, behind the PMMA beam spoiler screen and at treatment surface SSD = 380 cm) were derived from MC simulations. Results showed a final decrease in mean energy of almost 56% from the exit window to the treatment surface. A broader angular distribution (FWHM of the angular distribution increased from 13degrees at SSD = 100 cm to more than 30degrees at the treatment surface) was fully attributable to the PMMA beam spoiler screen. OF calculations and measurements agreed to less than 1%. The effect of changing the electron energy cut-off from 0.7 MeV to 0.521 MeV and air density fluctuations in the bunker which could affect the MC results were shown to have a negligible impact on the beam fluence distributions. Results proved the applicability of using MC as a treatment verification tool for complex radiotherapy techniques.
引用
下载
收藏
页码:2783 / 2796
页数:14
相关论文
共 50 条
  • [1] Total skin electron therapy treatment: Monte Carlo verification and beam characteristics
    Carrasco, E
    Sanchez-Doblado, F
    Leal, A
    Capote, R
    Lagares, J
    Rosello, J
    Perucha, M
    Arrans, R
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S92 - S92
  • [2] Monte Carlo simulation of large electron fields at extended distances: Total skin electron treatment optimization
    Shokrani, P
    Elson, H
    MEDICAL PHYSICS, 2005, 32 (07) : 2424 - 2424
  • [3] Monte Carlo simulation of large electron fields
    Faddegon, B
    Schreiber, E
    Ding, X
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (05): : 741 - 753
  • [4] Monte Carlo simulation of large electron fields
    Faddegon, Bruce A.
    Perl, Joseph
    Asai, Makoto
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (05): : 1497 - 1510
  • [5] Commissioning Total Skin Electron Therapy and Monte Carlo Verification of Patient Skin Dose
    Nie, W.
    Yeo, I.
    Huynh, K.
    Tong, S.
    Fan, J.
    MEDICAL PHYSICS, 2022, 49 (06) : E833 - E833
  • [6] Total skin electron therapy treatment optimization: Selection of an optimal scatterer using Monte Carlo simulation of single large scattered electron fields at extended distances
    Shokrani, P
    Elson, H
    MEDICAL PHYSICS, 2004, 31 (06) : 1924 - 1924
  • [7] Monte Carlo simulation of a total skin electron technique
    Gutierez, L
    Papanikolaou, N
    Yan, Y
    Wu, C
    MEDICAL PHYSICS, 2003, 30 (06) : 1515 - 1515
  • [8] Monte Carlo simulation of electron cones used in electron beam therapy
    Williams, T.
    Ebert, M.
    Keall, E.
    Haskard, D.
    Australasian Physical and Engineering Sciences in Medicine, 1998, 21 (03): : 112 - 119
  • [9] Monte Carlo Simulation and Measurement for Improving Dose Uniformity of Total Skin Electron Beam Therapy with Three Ports
    Ahn, S.
    Choi, J.
    Lee, H.
    Park, K.
    Suh, C. O.
    Kim, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E488 - E488
  • [10] Monte Carlo (MC) Simulation of Total Skin Electron Therapy (TSET) with TOPAS and EGSnrc
    Zhong, W.
    Ding, G.
    Ong, Y.
    Zhu, T.
    MEDICAL PHYSICS, 2021, 48 (06)