Total skin electron therapy treatment verification:: Monte Carlo simulation and beam characteristics of large non-standard electron fields

被引:1
|
作者
Pavón, EC
Sánchez-Doblado, F
Leal, A
Capote, R
Lagares, JI
Perucha, M
Arráns, R
机构
[1] Univ Seville, Fac Med, Dept Fisiol Med & Biofis, E-41009 Seville, Spain
[2] Univ Seville, Hosp Virgen Macarena, Serv Radiofis, E-41009 Seville, Spain
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2003年 / 48卷 / 17期
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Total skin electron therapy (TSET) is a complex technique which requires nonstandard measurements and dosimetric procedures. This paper investigates an essential first step towards TSET Monte Carlo (MC) verification. The non-standard 6 MeV 40 x 40 cm(2) electron beam at a source to surface distance (SSD) of 100 cm as well as its horizontal projection behind a polymethylmethacrylate (PMMA) screen to SSD = 380 cm were evaluated. The EGS4 OMEGA-BEAM code package running on a Linux home made 47 PCs cluster was used for the MC simulations. Percentage depth-dose curves and profiles were calculated and measured experimentally for the 40 x 40 cm(2) field at both SSD = 100 cm and patient surface SSD = 380 cm. The output factor (OF) between the reference 40 x 40 cm(2) open field and its horizontal projection as TSET beam at SSD = 380 cm was also measured for comparison with MC results. The accuracy of the simulated beam was validated by the good agreement to within 2% between measured relative dose distributions, including the beam characteristic parameters (R-50, R-80, R-100, R-p, E-0) and the MC calculated results. The energy spectrum, fluence and angular distribution at different stages of the beam (at SSD 100 cm, at SSD = 364.2 cm, behind the PMMA beam spoiler screen and at treatment surface SSD = 380 cm) were derived from MC simulations. Results showed a final decrease in mean energy of almost 56% from the exit window to the treatment surface. A broader angular distribution (FWHM of the angular distribution increased from 13degrees at SSD = 100 cm to more than 30degrees at the treatment surface) was fully attributable to the PMMA beam spoiler screen. OF calculations and measurements agreed to less than 1%. The effect of changing the electron energy cut-off from 0.7 MeV to 0.521 MeV and air density fluctuations in the bunker which could affect the MC results were shown to have a negligible impact on the beam fluence distributions. Results proved the applicability of using MC as a treatment verification tool for complex radiotherapy techniques.
引用
下载
收藏
页码:2783 / 2796
页数:14
相关论文
共 50 条
  • [31] NOVEL MONTE CARLO SIMULATION IN ELECTRON BEAM EXPOSURE.
    Wei, Mao-xin
    Wang, Jian-kun
    Qiao, Yi-zeng
    Microelectronic Engineering, 1985, 3 (1-4) : 99 - 104
  • [32] Validation of total skin electron irradiation (TSEI) technique dosimetry data by Monte Carlo simulation
    Nevelsky, Alexander
    Borzov, Egor
    Daniel, Shahar
    Bar-Deroma, Raquel
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 418 - 429
  • [33] Monte Carlo Simulation of In Vivo Verification for Small Aperture Electron Radiotherapy
    Li, K.
    MEDICAL PHYSICS, 2018, 45 (06) : E249 - E249
  • [34] Using electron beam modifiers in the DPM Monte Carlo code for electron beam treatment planning
    Tyagi, N.
    Tien, C.
    Curran, B.
    Fraass, B.
    MEDICAL PHYSICS, 2007, 34 (06) : 2502 - 2503
  • [35] Monte Carlo study on dose distributions from total skin electron irradiation therapy (TSET)
    Ding, George X.
    Osmundson, Evan C.
    Shinohara, Eric
    Newman, Neil B.
    Price, Michael
    Kirschner, Austin N.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (07):
  • [37] IMAGE SIMULATION USING MONTE-CARLO METHODS - ELECTRON-BEAM AND DETECTOR CHARACTERISTICS
    RADZIMSKI, ZJ
    RUSS, JC
    SCANNING, 1995, 17 (05) : 276 - 280
  • [38] Fast Monte Carlo algorithms for electron beam treatment planning
    Neuenschwander, H
    Volken, W
    Cris, C
    Mini, R
    Schwab, P
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 23 - 26
  • [39] A Monte Carlo Based Approach to Electron Beam Treatment Planning
    Mitrou, E.
    Alexander, A.
    Deblois, F.
    Thebaut, J.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [40] Electron beam modeling and commissioning for Monte Carlo treatment planning
    Jiang, SB
    Kapur, A
    Ma, CM
    MEDICAL PHYSICS, 2000, 27 (01) : 180 - 191