Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor

被引:368
|
作者
Shirato, H
Shimizu, S
Kitamura, K
Nishioka, T
Kagei, K
Hashimoto, S
Aoyama, H
Kunieda, T
Shinohara, N
Dosaka-Akita, H
Miyasaka, K
机构
[1] Hokkaido Univ, Sch Med, Dept Radiol, Sect Radiat Oncol,Kita Ku, Sapporo, Hokkaido 060, Japan
[2] Hokkaido Univ, Sch Med, Dept Urol, Sapporo, Hokkaido 060, Japan
[3] Hokkaido Univ, Sch Med, Dept Med, Sapporo, Hokkaido 060, Japan
[4] Mitsubishi Electr Corp, Tokyo 100, Japan
关键词
fluoroscopy; pattern recognition; localization; radiotherapy; conformal radiotherapy;
D O I
10.1016/S0360-3016(00)00625-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To achieve precise three-dimensional (3D) conformal radiotherapy for mobile tumors, a new radiotherapy system and its treatment planning system were developed and used for clinical practice. Methods and Materials: We developed a linear accelerator synchronized with a fluoroscopic real-time tumor tracking system by which 3D coordinates of a 2.0-mm gold marker in the tumor can be determined every 0.03 second, The 3D relationships between the marker and the tumor at different respiratory phases are evaluated using CT image at each respiratory phase, whereby the optimum phase can be selected to synchronize with irradiation (4D treatment planning). The linac is triggered to irradiate the tumor only when the marker is located within the region of the planned coordinates relative to the isocenter. Results: The coordinates of the marker were detected with an accuracy of +/- 1 mm during radiotherapy in the phantom experiment. The time delay between recognition of the marker position and the start or stop of megavoltage X-ray irradiation was 0.03 second. Fourteen patients with various tumors were treated by conformal radiotherapy with a "tight" planning target volume (PTV) margin, They were surviving without relapse or complications with a median follow-up of 6 months. Conclusion: Fluoroscopic real-time tumor tracking radiotherapy following 4D treatment planning was developed and shown to be feasible to improve the accuracy of the radiotherapy for mobile tumors. (C) 2000 Elsevier Science Inc.
引用
收藏
页码:435 / 442
页数:8
相关论文
共 50 条
  • [31] A Robust Tracking Algorithm for Implanted Marker of Fluoroscopic Images in a Real-Time Tumor-Tracking System
    Miyazaki, K.
    Fuji, Y.
    Umekawa, T.
    Yamada, T.
    Fujii, T.
    Miyamoto, N.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E473 - E473
  • [32] A four-dimensional controller for DMLC-based tumor tracking
    Keall, PJ
    Wijesooriya, K
    Vedam, S
    George, R
    Todor, D
    Murphy, M
    Siebers, J
    Williamson, J
    Mohan, R
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S338 - S339
  • [33] A real-time four-dimensional Doppler dealiasing scheme
    James, CN
    Houze, RA
    [J]. JOURNAL OF ATMOSPHERIC AND OCEANIC TECHNOLOGY, 2001, 18 (10) : 1674 - 1683
  • [34] A Kernel-Based Method for Real-Time Markerless Tumor Tracking in Fluoroscopic Image Sequence
    Zhang, Xiaoyong
    Homma, Noriyasu
    Takai, Yoshihiro
    Narita, Yuichiro
    Ichiji, Kei
    Abe, Makoto
    Sugita, Norihiro
    Yoshizawa, Makoto
    [J]. 2013 PROCEEDINGS OF SICE ANNUAL CONFERENCE (SICE), 2013, : 828 - 832
  • [35] Real-time markerless lung tumor tracking in fluoroscopic video: Handling overlapping of projected structures
    Teske, Hendrik
    Mercea, Paul
    Schwarz, Michael
    Nicolay, Nils H.
    Sterzing, Florian
    Bendl, Rolf
    [J]. MEDICAL PHYSICS, 2015, 42 (05) : 2540 - 2549
  • [36] Physical aspects of a real-time tumor-tracking system for gated radiotherapy
    Shirato, H
    Shimizu, S
    Kunieda, T
    Kitamura, K
    van Herk, M
    Kagei, K
    Nishioka, T
    Hashimoto, S
    Fujita, K
    Aoyama, H
    Tsuchiya, K
    Kudo, K
    Miyasaka, K
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (04): : 1187 - 1195
  • [37] Lung stereotactic body radiotherapy with electromagnetic transponders for real-time tumor tracking
    Jaccard, Maud
    Jaccard, M.
    Champion, A.
    Dubouloz, A.
    Plojoux, J.
    Soccal, P.
    Miralbell, R.
    Dipasquale, G.
    Caparrotti, F.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 (12) : 1126 - 1126
  • [38] A robotic approach to 4D real-time tumor tracking for radiotherapy
    Buzurovic, I.
    Huang, K.
    Yu, Y.
    Podder, T. K.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (05): : 1299 - 1318
  • [39] Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking
    Keall, PJ
    Joshi, S
    Vedam, SS
    Siebers, JV
    Kini, VR
    Mohan, R
    [J]. MEDICAL PHYSICS, 2005, 32 (04) : 942 - 951
  • [40] FOUR-DIMENSIONAL INTENSITY-MODULATED RADIOTHERAPY PLANNING FOR DYNAMIC MULTILEAF COLLIMATOR TRACKING RADIOTHERAPY
    Liang, Yueqiang
    Xu, Hongbing
    Yao, Jonathan
    Li, Zhihui
    Chen, Wendy
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (01): : 266 - 274