Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking

被引:236
|
作者
Keall, PJ
Joshi, S
Vedam, SS
Siebers, JV
Kini, VR
Mohan, R
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
[2] Univ N Carolina, Dept Radiat Oncol, Chapel Hill, NC 27514 USA
[3] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
[4] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
关键词
4D radiotherapy; deformable image registration; treatment planning;
D O I
10.1118/1.1879152
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. Temporal anatomic changes can occur for many reasons, though the focus of the current investigation is respiration motion for lung tumors. The aim of this study was to develop 4D radiotherapy treatment-planning methodology for DMLC-based respiratory motion tracking. A 4D computed tomography (CT) scan consisting of a series of eight 3D CT image sets acquired at different respiratory phases was used for treatment planning. Deformable image registration was performed to map each CT set from the peak-inhale respiration phase to the CT image sets corresponding to subsequent respiration phases. Deformable registration allows the contours defined on the peak-inhale CT to be automatically transferred to the other respiratory phase CT image sets. Treatment planning was simultaneously performed on each of the eight 3D image sets via automated scripts in which the MLC-defined beam aperture conforms to the PTV (which in this case equaled the GTV due to CT scan length limitations) plus a penumbral margin at each respiratory phase. The dose distribution from each respiratory phase CT image set was mapped back to the peak-inhale CT image set for analysis. The treatment intent of 4D planning is that the radiation beam defined by the DMLC tracks the respiration-induced target motion based on a feedback loop including the respiration signal to a real-time MLC controller. Deformation with respiration was observed for the lung tumor and normal tissues. This deformation was verified by examining the mapping of high contrast objects, such as the lungs and cord, between image sets. For the test case, dosimetric reductions for the cord, heart, and lungs were found for 4D planning compared with 3D planning. 4D radiotherapy planning for DMLC-based respiratory motion tracking is feasible and may offer tumor dose escalation and/or a reduction in treatment-related complications. However, 4D planning requires new planning tools, such as deformable registration and automated treatment planning on multiple CT image sets. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:942 / 951
页数:10
相关论文
共 50 条
  • [1] A four-dimensional controller for DMLC-based tumor tracking
    Keall, PJ
    Wijesooriya, K
    Vedam, S
    George, R
    Todor, D
    Murphy, M
    Siebers, J
    Williamson, J
    Mohan, R
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S338 - S339
  • [2] Four-dimensional IMRT treatment planning using a DMLC motion-tracking algorithm
    Suh, Yelin
    Sawant, Amit
    Venkat, Raghu
    Keall, Paul J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (12): : 3821 - 3835
  • [3] Predicting respiratory motion for four-dimensional radiotherapy
    Vedam, SS
    Keall, PJ
    Docef, A
    Todor, DA
    Kini, VR
    Mohan, R
    MEDICAL PHYSICS, 2004, 31 (08) : 2274 - 2283
  • [4] Respiratory gated and four-dimensional tumor tracking radiotherapy
    Keall, P.
    MEDICAL PHYSICS, 2006, 33 (06) : 2227 - 2228
  • [5] Respiratory gated and four-dimensional tumor tracking radiotherapy
    Keall, P
    LUNG CANCER, 2005, 49 : S56 - S56
  • [6] Four-dimensional radiotherapy planning
    Keall, P
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S140 - S140
  • [7] Assessment of Four-dimensional Radiotherapy Planning and Respiratory Motion-induced Dose Difference Based on Radiological Measures
    Su, Fan-Chi
    Shi, Chengyu
    Mavroidis, Panayiotis
    Papanikolaou, Niko
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2009, 32 (01): : 104 - 104
  • [8] Monte Carlo as a four-dimensional radiotherapy treatment-planning tool to account for respiratory motion
    Keall, PJ
    Siebers, JV
    Joshi, S
    Mohan, R
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (16): : 3639 - 3648
  • [9] Tumor motion tracking based on a four-dimensional computed tomography respiratory motion model driven by an ultrasound tracking technique
    Ting, Lai-Lei
    Chuang, Ho-Chiao
    Liao, Ai-Ho
    Kuo, Chia-Chun
    Yu, Hsiao-Wei
    Tsai, Hsin-Chuan
    Tien, Der-Chi
    Jeng, Shiu-Chen
    Chiou, Jeng-Fong
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (01) : 26 - 39
  • [10] Assessing Four-dimensional Radiotherapy Planning and Respiratory Motion-induced Dose Difference Based on Biologically Effective Uniform Dose
    Su, Fan-Chi
    Shi, Chengyu
    Mavroidis, Panayiotis
    Goytia, Virginia
    Crownover, Richard
    Rassiah-Szegedi, Prema
    Papanikolaou, Niko
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2009, 8 (03) : 187 - 199