Calibration of the Electromagnetic Calorimeter of the CMS experiment

被引:0
|
作者
Argiro, S. [1 ]
机构
[1] Univ Turin, I-10124 Turin, Italy
关键词
D O I
10.1016/j.nuclphysbps.2009.10.104
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
The electromagnetic calorimeter (ECAL) of the CMS experiment is an homogeneous, hermetic detector with high granularity. Its potential performances are outstanding in terms of energy resolution, dynamic range and noise level. These characteristics make the calorimeter the most powerful device in the search of the decay in two photons of the Higgs particle. However, the energy resolution depends crucially on the channel to channel intercalibration precision. Therefore, great attention must be given to the calibration process. In this contribution we will describe the strategy that the ECAL group has devised to calibrate the detector. We will report on the pre-calibration processes that have already been performed, the strategies for intercalibration at startup and those foreseen when sufficient statistics will be accumulated to use W and Z events. For the normal data taking regime, an intercalibration precision of 0.5% should be reached, while the response of the detector will be monitored regularly.
引用
收藏
页码:362 / 365
页数:4
相关论文
共 50 条
  • [41] The CMS Electromagnetic Calorimeter
    Paganoni, Marco
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1034 - 1037
  • [42] Calibration and Performance of the CMS Electromagnetic Calorimeter in LHC Run2
    Cavallari, Francesca
    Rovelli, Chiara
    24TH INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP 2019), 2020, 245
  • [43] Calibration and performance of the CMS Electromagnetic Calorimeter in LHC Run-II
    Kuo, C. M.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (06):
  • [44] Maintaining and improving the control and safety systems for the Electromagnetic Calorimeter of the CMS experiment
    Di Calafiori, D.
    Adzic, P.
    Dissertori, G.
    Holme, O.
    Jovanovic, D.
    Lustermann, W.
    Zelepoukine, S.
    INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS 2012 (CHEP2012), PTS 1-6, 2012, 396
  • [45] Intercalibration of the barrel electromagnetic calorimeter of the CMS experiment at start-up
    Adzic, P.
    Alemany-Fernandez, R.
    Almeida, N.
    Anagnostou, G.
    Andelin, D.
    Anfreville, M.
    Anicin, I.
    Antunovic, Z.
    Arcidiacono, R.
    Arenton, M. W.
    Auffray, E.
    Argiro, S.
    Askew, A.
    Atramentov, O.
    Baccaro, S.
    Baffioni, S.
    Balazs, M.
    Barney, D.
    Barone, L. M.
    Bartoloni, A.
    Baty, C.
    Bandurin, D.
    Beauceron, S.
    Bell, K. W.
    Benetta, R.
    Bercher, M.
    Bernet, C.
    Berthon, U.
    Besancon, M.
    Betev, B.
    Beuselinck, R.
    Biino, C.
    Blaha, J.
    Bloch, P.
    Blyth, S.
    Bornheim, A.
    Bourotte, J.
    Brett, A. M.
    Brown, R. M.
    Britton, D.
    Buehler, M.
    Busson, P.
    Camanzi, B.
    Camporesi, T.
    Carrera, E.
    Cartiglia, N.
    Cavallari, F.
    Cerutti, M.
    Chang, P.
    Chang, Y. H.
    JOURNAL OF INSTRUMENTATION, 2008, 3
  • [46] PERFORMANCE OF THE CMS ELECTROMAGNETIC CALORIMETER
    Pastrone, N.
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 354 - 358
  • [47] The CMS electromagnetic calorimeter readout
    Martin, F
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 1999, 78 : 192 - 196
  • [48] Overview of the CMS electromagnetic calorimeter
    Ernenwein, JP
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 1999, 78 : 186 - 191
  • [49] The CMS electromagnetic calorimeter at the LHC
    Ryan, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 598 (01): : 217 - 219
  • [50] The CMS Electromagnetic Calorimeter workflow
    Rovelli, Chiara
    24TH INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP 2019), 2020, 245