Calibration of the Electromagnetic Calorimeter of the CMS experiment

被引:0
|
作者
Argiro, S. [1 ]
机构
[1] Univ Turin, I-10124 Turin, Italy
关键词
D O I
10.1016/j.nuclphysbps.2009.10.104
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
The electromagnetic calorimeter (ECAL) of the CMS experiment is an homogeneous, hermetic detector with high granularity. Its potential performances are outstanding in terms of energy resolution, dynamic range and noise level. These characteristics make the calorimeter the most powerful device in the search of the decay in two photons of the Higgs particle. However, the energy resolution depends crucially on the channel to channel intercalibration precision. Therefore, great attention must be given to the calibration process. In this contribution we will describe the strategy that the ECAL group has devised to calibrate the detector. We will report on the pre-calibration processes that have already been performed, the strategies for intercalibration at startup and those foreseen when sufficient statistics will be accumulated to use W and Z events. For the normal data taking regime, an intercalibration precision of 0.5% should be reached, while the response of the detector will be monitored regularly.
引用
收藏
页码:362 / 365
页数:4
相关论文
共 50 条
  • [31] The electromagnetic calorimeter of CMS
    Funk, Wolfgang
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) : 2881 - 2886
  • [32] The CMS electromagnetic calorimeter
    Paramatti, R
    IFAE 2005: 17th Italian Meeting on High Energy Physics, 2005, 794 : 291 - 294
  • [33] The CMS Electromagnetic Calorimeter
    Ryan, M.
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 501 - 505
  • [34] The CMS electromagnetic calorimeter
    Organtini, G
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 554 - 556
  • [35] The CMS electromagnetic calorimeter
    Organtini, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 478 (1-2): : 333 - 335
  • [36] The electromagnetic calorimeter of CMS
    Funk, Wolfgang
    CZECHOSLOVAK JOURNAL OF PHYSICS, 2006, 56 : F329 - F340
  • [37] The CMS electromagnetic calorimeter
    Britton, DI
    CZECHOSLOVAK JOURNAL OF PHYSICS, 2000, 50 : 69 - 78
  • [38] The CMS electromagnetic Calorimeter
    Particle Physics Department, Rutherford Appleton Laboratory, Chilton, OX11 0QX, United Kingdom
    Nucl Instrum Methods Phys Res Sect A, 2007, 1 SPEC. ISS. (29-32):
  • [39] The CMS electromagnetic calorimeter
    Musienko, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 494 (1-3): : 308 - 312
  • [40] The CMS electromagnetic calorimeter
    Paganoni, Marco
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (03) : 574 - 577