In situ determination of antimony isotope ratios in Sb minerals by femtosecond LA-MC-ICP-MS

被引:15
|
作者
Kaufmann, A. B. [1 ,2 ]
Lazarov, M. [1 ]
Kiefer, S. [2 ]
Majzlan, J. [2 ]
Weyer, S. [1 ]
机构
[1] Leibniz Univ Hannover, Inst Mineral, Hannover, Germany
[2] Friedrich Schiller Univ Jena, Inst Geosci, Jena, Germany
关键词
PLASMA-MASS SPECTROMETRY; LASER-ABLATION; ULTRAVIOLET-FEMTOSECOND; PRECISE DETERMINATION; PURIFICATION METHOD; FRACTIONATION; MOBILITY; PEZINOK; SYSTEM; COPPER;
D O I
10.1039/d1ja00089f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Here we present a method for in situ determination of stable antimony (Sb) isotope compositions by ultraviolet (UV)-femtosecond-laser-ablation-multi-collector-ICP-MS (fs-LA-MC-ICP-MS). Metallic antimony and a number of Sb minerals (stibnite, senarmontite, chalcostibite, tetrahedrite, boulangerite, bournonite, zinkenite, pyrargyrite and dyscrasite) have been investigated. In order to verify the results of the in situ method, LA-MC-ICP-MS measurements were compared with solution MC-ICP-MS analyses on two chemically homogeneous stibnite samples and Sb metal. The internal precision of in situ measurements was better than 0.045 parts per thousand. The long-term reproducibility for these three materials was better than 0.1 parts per thousand. These results imply that any of these three materials may be used as an in situ Sb isotope standard. All delta Sb-123 values were determined by applying a standard-sample bracketing protocol and mass bias correction using Sn (NIST SRM 3161a standard solution) isotope ratios. Since no certified Sb isotope standard is currently available, in situ isotope analyses were performed in bracketing to a stibnite in-house standard and subsequently recalculated relative to NIST SRM 3102a. Matrix effects from Cu, Pb, Ag, Fe and Zn on the natural mineral Sb isotope ratios were insignificant. The mass interference of Te-123 on Sb-123 can only precisely be corrected for materials with Te/Sb <= 0.2. The LA and solution analyses of delta Sb-123 homogeneous zinkenite, dyscrasite and pyrargyrite agree excellently with each other. Senarmontite shows more variable delta Sb-123 at small scales, determined with LA-MC-ICP-MS, but homogeneous delta Sb-123 determined by solution analyses with a small offset between solution and LA analyses. Other minerals, like boulangerite, show heterogeneous delta Sb-123 (approximate to 0.5 parts per thousand) for both solution and LA analyses. Overall, these results demonstrate that fs-LA-MC-ICP-MS is suitable to measure Sb isotopic ratios in Sb-rich sulfides, sulfosalts and oxides (excluding Sb tellurides) with a precision better than 0.1 parts per thousand and a spatial resolution of approximate to 30 mu m. Thus, it may be used as a tool to analyse spatially resolved Sb isotope composition at the mineral or even sub-mineral scale, e.g. to address the processes of ore formation or Sb redistribution in near-surface environments.
引用
收藏
页码:1554 / 1567
页数:14
相关论文
共 50 条
  • [31] Development of Synthetic Clinopyroxene Reference Materials for In Situ Lithium Isotope Measurement by LA-MC-ICP-MS
    Yang, Ao
    Lin, Jie
    Liu, Yongsheng
    Liu, Zhenyi
    Lin, Ran
    Deng, Kexin
    Hu, Zhaochu
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2023, 47 (03) : 535 - 546
  • [32] In situ Sr-Nd isotope analysis of vesuvianite by LA-MC-ICP-MS: methodology and application
    Wei, Qin-Di
    Yang, Yue-Heng
    Wang, Hao
    Wu, Shi-Tou
    Yang, Ming
    Huang, Chao
    Xu, Lei
    Xie, Lie-Wen
    Yang, Jin-Hui
    Wu, Fu-Yuan
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (05) : 1284 - 1301
  • [33] Calibration and correction of LA-ICP-MS and LA-MC-ICP-MS analyses for element contents and isotopic ratios
    Lin, Jie
    Liu, Yongsheng
    Yang, Yueheng
    Hu, Zhaochu
    SOLID EARTH SCIENCES, 2016, 1 (01) : 5 - 27
  • [34] Advancing Biomarker Research: In Situ Cu Isotope Analysis in Liver Tumors by LA-MC-ICP-MS
    Schannor, Mathias
    Oelze, Marcus
    Traub, Heike
    He, Yubei
    Schmidt, Robin
    Heidemann, Luisa
    Savic, Lynn Jeanette
    Vogl, Jochen
    Meermann, Bjoern
    ANALYTICAL CHEMISTRY, 2025, 97 (08) : 4425 - 4432
  • [35] Sources of Inaccuracy in Boron Isotope Measurement Using LA-MC-ICP-MS
    Fietzke, Jan
    Anagnostou, Eleni
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2023, 47 (03) : 481 - 492
  • [36] Alternative data reduction for precise and accurate isotope ratio determination via LA-MC-ICP-MS
    Fietzke, J.
    Liebetrau, V.
    Guenther, D.
    Frische, A.
    Zumholz, K.
    Hansteen, T. H.
    Eisenhauer, A.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2008, 72 (12) : A267 - A267
  • [37] In situ Pb-isotope analysis by LA-MC-ICP-MS: Applications to geochemistry, geochronology, palaeoceanography and archaeology
    Kent, AJR
    Baker, JA
    Waight, TE
    Ukstins, IA
    Vry, J
    Stos, S
    Graham, IJ
    Wright, IC
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2002, 66 (15A) : A395 - A395
  • [38] Strontium isotope analysis of kimberlitic groundmass perovskite via LA-MC-ICP-MS
    Paton, Chad
    Woodhead, Jon D.
    Hergt, Janet M.
    Phillips, David
    Shee, Simon
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2007, 31 (04) : 321 - 330
  • [39] TC1725: a proposed chalcopyrite reference material for LA-MC-ICP-MS sulfur isotope determination
    Bao, Zhian
    Chen, Kaiyun
    Zong, Chunlei
    Yuan, Honglin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (08) : 1657 - 1665
  • [40] Development of pressed sulfide powder tablets for in situ sulfur and lead isotope measurement using LA-MC-ICP-MS
    Bao, Zhian
    Chen, Lu
    Zong, Chunlei
    Yuan, Honglin
    Chen, Kaiyun
    Dai, Mengning
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2017, 421 : 255 - 262