In situ determination of antimony isotope ratios in Sb minerals by femtosecond LA-MC-ICP-MS

被引:15
|
作者
Kaufmann, A. B. [1 ,2 ]
Lazarov, M. [1 ]
Kiefer, S. [2 ]
Majzlan, J. [2 ]
Weyer, S. [1 ]
机构
[1] Leibniz Univ Hannover, Inst Mineral, Hannover, Germany
[2] Friedrich Schiller Univ Jena, Inst Geosci, Jena, Germany
关键词
PLASMA-MASS SPECTROMETRY; LASER-ABLATION; ULTRAVIOLET-FEMTOSECOND; PRECISE DETERMINATION; PURIFICATION METHOD; FRACTIONATION; MOBILITY; PEZINOK; SYSTEM; COPPER;
D O I
10.1039/d1ja00089f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Here we present a method for in situ determination of stable antimony (Sb) isotope compositions by ultraviolet (UV)-femtosecond-laser-ablation-multi-collector-ICP-MS (fs-LA-MC-ICP-MS). Metallic antimony and a number of Sb minerals (stibnite, senarmontite, chalcostibite, tetrahedrite, boulangerite, bournonite, zinkenite, pyrargyrite and dyscrasite) have been investigated. In order to verify the results of the in situ method, LA-MC-ICP-MS measurements were compared with solution MC-ICP-MS analyses on two chemically homogeneous stibnite samples and Sb metal. The internal precision of in situ measurements was better than 0.045 parts per thousand. The long-term reproducibility for these three materials was better than 0.1 parts per thousand. These results imply that any of these three materials may be used as an in situ Sb isotope standard. All delta Sb-123 values were determined by applying a standard-sample bracketing protocol and mass bias correction using Sn (NIST SRM 3161a standard solution) isotope ratios. Since no certified Sb isotope standard is currently available, in situ isotope analyses were performed in bracketing to a stibnite in-house standard and subsequently recalculated relative to NIST SRM 3102a. Matrix effects from Cu, Pb, Ag, Fe and Zn on the natural mineral Sb isotope ratios were insignificant. The mass interference of Te-123 on Sb-123 can only precisely be corrected for materials with Te/Sb <= 0.2. The LA and solution analyses of delta Sb-123 homogeneous zinkenite, dyscrasite and pyrargyrite agree excellently with each other. Senarmontite shows more variable delta Sb-123 at small scales, determined with LA-MC-ICP-MS, but homogeneous delta Sb-123 determined by solution analyses with a small offset between solution and LA analyses. Other minerals, like boulangerite, show heterogeneous delta Sb-123 (approximate to 0.5 parts per thousand) for both solution and LA analyses. Overall, these results demonstrate that fs-LA-MC-ICP-MS is suitable to measure Sb isotopic ratios in Sb-rich sulfides, sulfosalts and oxides (excluding Sb tellurides) with a precision better than 0.1 parts per thousand and a spatial resolution of approximate to 30 mu m. Thus, it may be used as a tool to analyse spatially resolved Sb isotope composition at the mineral or even sub-mineral scale, e.g. to address the processes of ore formation or Sb redistribution in near-surface environments.
引用
收藏
页码:1554 / 1567
页数:14
相关论文
共 50 条
  • [21] A simplified procedure for the determination of stable chlorine isotope ratios (δ37Cl) using LA-MC-ICP-MS
    Fietzke, Jan
    Frische, Matthias
    Hansteen, Thor H.
    Eisenhauer, Anton
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (05) : 769 - 772
  • [22] Review on in situ Isotopic Analysis by LA-MC-ICP-MS
    Jie Lin
    Ao Yang
    Ran Lin
    Ji Mao
    Zhaochu Hu
    Yongsheng Liu
    Journal of Earth Science, 2023, 34 (06) : 1663 - 1691
  • [23] Review on in situ Isotopic Analysis by LA-MC-ICP-MS
    Jie Lin
    Ao Yang
    Ran Lin
    Ji Mao
    Zhaochu Hu
    Yongsheng Liu
    Journal of Earth Science, 2023, (06) : 1663 - 1691
  • [24] Review on in situ Isotopic Analysis by LA-MC-ICP-MS
    Lin, Jie
    Yang, Ao
    Lin, Ran
    Mao, Ji
    Hu, Zhaochu
    Liu, Yongsheng
    JOURNAL OF EARTH SCIENCE, 2023, 34 (06) : 1663 - 1691
  • [25] In situ determination of hafnium isotopes from rutile using LA-MC-ICP-MS
    Yang Li
    YueHeng Yang
    ShuJuan Jiao
    FuYuan Wu
    JinHui Yang
    LieWen Xie
    Chao Huang
    Science China Earth Sciences, 2015, 58 : 2134 - 2144
  • [26] In situ determination of hafnium isotopes from rutile using LA-MC-ICP-MS
    LI Yang
    YANG YueHeng
    JIAO ShuJuan
    WU FuYuan
    YANG JinHui
    XIE LieWen
    HUANG Chao
    Science China(Earth Sciences), 2015, 58 (12) : 2134 - 2144
  • [27] In situ determination of hafnium isotopes from rutile using LA-MC-ICP-MS
    Li Yang
    Yang YueHeng
    Jiao ShuJuan
    Wu FuYuan
    Yang JinHui
    Xie LieWen
    Huang Chao
    SCIENCE CHINA-EARTH SCIENCES, 2015, 58 (12) : 2134 - 2144
  • [28] In situ lithium and boron isotope determinations in mica, pyroxene, and serpentine by LA-MC-ICP-MS
    Martin, Celine
    Ponzevera, Emmanuel
    Harlow, George
    CHEMICAL GEOLOGY, 2015, 412 : 107 - 116
  • [29] In Situ Boron Isotope Determination in Amphibole by LA-MC-ICP-MS: Matrix Effects and New Potential Reference Materials
    Cannao, Enrico
    Sessa, Gianluca
    Agostini, Samuele
    Tiepolo, Massimo
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2025,
  • [30] Lead isotope analysis of melt inclusions by LA-MC-ICP-MS
    Zhang, Le
    Ren, Zhong-Yuan
    Nichols, Alexander R. L.
    Zhang, Yin-Hui
    Zhang, Yan
    Qian, Sheng-Ping
    Liu, Jian-Qiang
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (08) : 1393 - 1405