In situ determination of antimony isotope ratios in Sb minerals by femtosecond LA-MC-ICP-MS

被引:15
|
作者
Kaufmann, A. B. [1 ,2 ]
Lazarov, M. [1 ]
Kiefer, S. [2 ]
Majzlan, J. [2 ]
Weyer, S. [1 ]
机构
[1] Leibniz Univ Hannover, Inst Mineral, Hannover, Germany
[2] Friedrich Schiller Univ Jena, Inst Geosci, Jena, Germany
关键词
PLASMA-MASS SPECTROMETRY; LASER-ABLATION; ULTRAVIOLET-FEMTOSECOND; PRECISE DETERMINATION; PURIFICATION METHOD; FRACTIONATION; MOBILITY; PEZINOK; SYSTEM; COPPER;
D O I
10.1039/d1ja00089f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Here we present a method for in situ determination of stable antimony (Sb) isotope compositions by ultraviolet (UV)-femtosecond-laser-ablation-multi-collector-ICP-MS (fs-LA-MC-ICP-MS). Metallic antimony and a number of Sb minerals (stibnite, senarmontite, chalcostibite, tetrahedrite, boulangerite, bournonite, zinkenite, pyrargyrite and dyscrasite) have been investigated. In order to verify the results of the in situ method, LA-MC-ICP-MS measurements were compared with solution MC-ICP-MS analyses on two chemically homogeneous stibnite samples and Sb metal. The internal precision of in situ measurements was better than 0.045 parts per thousand. The long-term reproducibility for these three materials was better than 0.1 parts per thousand. These results imply that any of these three materials may be used as an in situ Sb isotope standard. All delta Sb-123 values were determined by applying a standard-sample bracketing protocol and mass bias correction using Sn (NIST SRM 3161a standard solution) isotope ratios. Since no certified Sb isotope standard is currently available, in situ isotope analyses were performed in bracketing to a stibnite in-house standard and subsequently recalculated relative to NIST SRM 3102a. Matrix effects from Cu, Pb, Ag, Fe and Zn on the natural mineral Sb isotope ratios were insignificant. The mass interference of Te-123 on Sb-123 can only precisely be corrected for materials with Te/Sb <= 0.2. The LA and solution analyses of delta Sb-123 homogeneous zinkenite, dyscrasite and pyrargyrite agree excellently with each other. Senarmontite shows more variable delta Sb-123 at small scales, determined with LA-MC-ICP-MS, but homogeneous delta Sb-123 determined by solution analyses with a small offset between solution and LA analyses. Other minerals, like boulangerite, show heterogeneous delta Sb-123 (approximate to 0.5 parts per thousand) for both solution and LA analyses. Overall, these results demonstrate that fs-LA-MC-ICP-MS is suitable to measure Sb isotopic ratios in Sb-rich sulfides, sulfosalts and oxides (excluding Sb tellurides) with a precision better than 0.1 parts per thousand and a spatial resolution of approximate to 30 mu m. Thus, it may be used as a tool to analyse spatially resolved Sb isotope composition at the mineral or even sub-mineral scale, e.g. to address the processes of ore formation or Sb redistribution in near-surface environments.
引用
收藏
页码:1554 / 1567
页数:14
相关论文
共 50 条
  • [1] In situ precise determination of stable Mo isotope ratios in molybdenite by femtosecond LA-MC-ICP-MS
    Tian, Jing
    Bao, Zhian
    Chen, Kaiyun
    Zong, Chunlei
    Zhang, Yan
    Peng, Deyi
    Yuan, Honglin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (08) : 2021 - 2029
  • [2] In situ precise determination of stable Mo isotope ratios in molybdenite by femtosecond LA-MC-ICP-MS
    Tian, Jing
    Bao, Zhian
    Chen, Kaiyun
    Zong, Chunlei
    Zhang, Yan
    Peng, Deyi
    Yuan, Honglin
    Journal of Analytical Atomic Spectrometry, 1600, 39 (08): : 2021 - 2029
  • [3] In situ-Fe isotope determination using femtosecond LA-MC-ICP-MS
    Steinhoefel, G
    Horn, I
    Schoenberg, R
    Von Blanckenburg, F
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2005, 69 (10) : A374 - A374
  • [4] In situ determination of Cu isotope ratios in copper-rich materials by NIR femtosecond LA-MC-ICP-MS
    Ikehata, Kei
    Notsu, Kenji
    Hirata, Takafumi
    Journal of Analytical Atomic Spectrometry, 2008, 23 (07): : 1003 - 1008
  • [5] In situ determination of Cu isotope ratios in copper-rich materials by NIR femtosecond LA-MC-ICP-MS
    Ikehata, Kei
    Notsu, Kenji
    Hirata, Takafumi
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (07) : 1003 - 1008
  • [6] Accurate determination of Ba isotope ratios in barite samples by LA-MC-ICP-MS
    Zhang, Shenghua
    Zhang, Wen
    Yu, Huimin
    Huang, Fang
    Wang, Chao
    Luo, Tao
    Liu, Yongsheng
    Hu, Zhaochu
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (12) : 2637 - 2646
  • [7] In situ lithium isotope analysis by LA-MC-ICP-MS
    le Roux, P. J.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2009, 73 (13) : A744 - A744
  • [8] In situ carbon isotope analysis of diamonds using LA-MC-ICP-MS inspired by the distribution of ions and isotope ratios in ICP
    Huo, Yi-Ming
    Zhu, Zhi-Yong
    Fan, Chang-Fu
    She, Yu-Wei
    Hao, Jia-Long
    Zhu, Xiang-Kun
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2025, 40 (03)
  • [9] ANALYSIS OF TITANIUM ISOTOPE RATIOS IN REFRACTORY INCLUSIONS BY LA-MC-ICP-MS
    Williams, C. D.
    Wadhwa, M.
    Janney, P. E.
    Hines, R. R.
    Bullock, E. S.
    MacPherson, G. J.
    METEORITICS & PLANETARY SCIENCE, 2011, 46 : A250 - A250
  • [10] High-Precision Fe and Mg Isotope Ratios of Silicate Reference Glasses Determined In Situ by Femtosecond LA-MC-ICP-MS and by Solution Nebulisation MC-ICP-MS
    Oeser, Martin
    Weyer, Stefan
    Horn, Ingo
    Schuth, Stephan
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2014, 38 (03) : 311 - 328