A multi-level drill guide template improves the accuracy of pedicle screw placement in lumbar spine

被引:1
|
作者
Ge, D. -W. [1 ]
Yang, L. [2 ]
Chen, X. [2 ]
Tang, J. [1 ]
Chen, H. -T. [1 ]
Li, H. -J. [3 ]
Sui, T. [1 ]
Zhuang, Y. [4 ]
Zheng, S. -N. [2 ]
Cao, X. -J. [1 ]
机构
[1] Nanjing Med Univ, Dept Orthoped, Affiliated Hosp 1, Nanjing, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Dept Orthoped, Nanjing Hosp 1, Nanjing, Peoples R China
[3] Nantong Univ, Dept Orthoped, Taizhou Peoples Hosp, Taizhou, Jiangsu, Peoples R China
[4] Southeast Univ, Sch Med, Dept Orthoped, Affiliated Jiangyin Hosp, Wuxi, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Pedicle screw; Three-dimensional; Guide device; Lumbar spine; Rapid prototyping; ASSISTED ORTHOPEDIC-SURGERY; INDIVIDUAL TEMPLATES; THORACIC SPINE; FREE HAND; THORACOLUMBAR; SAFE; NAVIGATION; FRACTURES; GUIDANCE;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
OBJECTIVE: Free-hand technique is widely used in pedicle screw placement for lumbar spine and generally safe; however, screw malposition still occurs. To develop a novel multi-level drill guide template for pedicle screw placement in lumbar spine and evaluate its accuracy. MATERIALS AND METHODS: Twelve lumbar cadaveric specimens were randomly allocated into guide template group (n=6) and free-hand group (n=6). Computed tomography (CT) scans were obtained for reconstruction of three-dimensional (3D) model of each lumbar vertebra, and further an individual guide template was designed. Then the templates and their corresponding vertebra were developed by rapid prototyping (RP) technology. With the guide of the templates, screws were inserted via mini-open Wiltse approach. The positions of the screws were assessed based on postoperative CT images. RESULTS: In total, 120 pedicle screws inserted (guide template group: n=60 vs. free-hand group: n=60). For all 30 vertebras in the guide template group, all pre-designed personalized drill guide templates can be fitted into the facet joints of each vertebra well. Furthermore, our results revealed a significant improvement for the guide template group in the accuracy rate (p=0.026). CONCLUSIONS: Armed with advantages of minimal invasion, enhanced accuracy and safety, the novel technique of multi-level drill guide template can be properly applied in pedicle screw placement for lumbar spine and promises to be a potential option in clinical application.
引用
收藏
页码:3643 / 3648
页数:6
相关论文
共 50 条
  • [11] Evaluation of a transpedicular drill guide for pedicle screw placement in the thoracic spine
    Mac-Thiong, JM
    Labelle, H
    Rooze, M
    Feipel, V
    Aubin, CE
    [J]. EUROPEAN SPINE JOURNAL, 2003, 12 (05) : 542 - 547
  • [12] Evaluation of a transpedicular drill guide for pedicle screw placement in the thoracic spine
    Jean-Marc Mac-Thiong
    Hubert Labelle
    Marcel Rooze
    Véronique Feipel
    Carl-Eric Aubin
    [J]. European Spine Journal, 2003, 12 : 542 - 547
  • [13] Percutaneous Pedicle Screw Placement Aided by a New Drill Guide Template Combined with Fluoroscopy: An Accuracy Study
    Wu, Chao
    Deng, Jiayan
    Li, Tao
    Tan, Lun
    Yuan, Dechao
    [J]. ORTHOPAEDIC SURGERY, 2020, 12 (02) : 471 - 479
  • [14] CLINICAL APPLICATION OF A DRILL GUIDE TEMPLATE FOR PEDICLE SCREW PLACEMENT IN SEVERE SCOLIOSIS
    Li, Xin
    Zhang, Yaoshen
    Zhang, Qiang
    Zhao, Changsong
    Liu, Kun
    [J]. ACTA ORTOPEDICA BRASILEIRA, 2017, 25 (02): : 67 - 70
  • [15] A novel computer-assisted drill guide template for lumbar pedicle screw placement: a cadaveric and clinical study
    Lu, Sheng
    Xu, Yong Q.
    Zhang, Yuan Z.
    Li, Yan B.
    Xie, L. E.
    Shi, Ji H.
    Guo, Hai
    Chen, Guo P.
    Chen, Yu B.
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2009, 5 (02): : 184 - 191
  • [16] A novel guide device improves the accuracy of pedicle screw placement
    Yang, Lei
    Li, Haijun
    Tang, Jian
    Ge, Dawei
    Cao, Xiaojian
    [J]. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (06): : 8634 - 8640
  • [17] Efficacy and accuracy of a novel rapid prototyping drill template for cervical pedicle screw placement
    Lu, Sheng
    Xu, Yong Q.
    Chen, Guo P.
    Zhang, Yuan Z.
    Lu, Di
    Chen, Yu B.
    Shi, Ji H.
    Xu, Xing M.
    [J]. COMPUTER AIDED SURGERY, 2011, 16 (05) : 240 - 248
  • [18] Accuracy of pedicle screw placement in lumbar vertebrae
    Castro, WHM
    Halm, H
    Jerosch, J
    Malms, J
    Steinbeck, J
    Blasius, S
    [J]. SPINE, 1996, 21 (11) : 1320 - 1324
  • [19] The Utility of a Digital Virtual Template for Junior Surgeons in Pedicle Screw Placement in the Lumbar Spine
    Zhao, Xin
    Zhao, Jie
    Xie, Youzhuan
    Mi, Jie
    [J]. BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [20] A medium invasiveness multi-level patient's specific template for pedicle screw placement in the scoliosis surgery
    Azimifar, Farhad
    Hassani, Kamran
    Saveh, Amir Hossein
    Ghomsheh, Farhad Tabatabai
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2017, 16