A medium invasiveness multi-level patient's specific template for pedicle screw placement in the scoliosis surgery

被引:12
|
作者
Azimifar, Farhad [1 ]
Hassani, Kamran [1 ]
Saveh, Amir Hossein [2 ]
Ghomsheh, Farhad Tabatabai [3 ]
机构
[1] Islamic Azad Univ, Sci & Res Branch, Dept Biomech, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Shohada Tajrish Neurosurg Comprehens Ctr Excellen, Funct Neurosurg Res Ctr, Tehran, Iran
[3] Univ Social Welf & Rehabil Sci USWR, Ergon Dept, Pediat Neurorehabil Res Ctr, Tehran, Iran
来源
关键词
Multi-level; Template; Spine; Surgery; FREE-HAND TECHNIQUE; DRILL GUIDE TEMPLATE; COMPUTED-TOMOGRAPHY; THORACOLUMBAR SPINE; ROBOTIC GUIDANCE; SACRAL SPINE; LUMBAR SPINE; IN-VIVO; ACCURACY; FLUOROSCOPY;
D O I
10.1186/s12938-017-0421-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Several methods including free-hand technique, fluoroscopic guidance, image-guided navigation, computer-assisted surgery system, robotic platform and patient's specific templates are being used for pedicle screw placement. These methods have screw misplacements and are not always easy to be applied. Furthermore, it is necessary to expose completely a large portions of the spine in order to access fit entirely around the vertebrae. Methods: In this study, a multi-level patient's specific template with medium invasiveness was proposed for pedicle screw placement in the scoliosis surgery. It helps to solve the problems related to the soft tissues removal. After a computer tomography (CT) scan of the spine, the templates were designed based on surgical considerations. Each template was manufactured using three-dimensional printing technology under a semi-flexible post processing. The templates were placed on vertebras at four points-at the base of the superior-inferior articular processes on both left-right sides. This helps to obtain less invasive and more accurate procedure as well as true-stable and easy placement in a unique position. The accuracy of screw positions was confirmed by CT scan after screw placement. Results: The result showed the correct alignment in pedicle screw placement. In addition, the template has been initially tested on a metal wire series Moulage (height 70 cm and material is PVC). The results demonstrated that it could be possible to implement it on a real patient. Conclusions: The proposed template significantly reduced screw misplacements, increased stability, and decreased the sliding & the intervention invasiveness.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] A medium invasiveness multi-level patient’s specific template for pedicle screw placement in the scoliosis surgery
    Farhad Azimifar
    Kamran Hassani
    Amir Hossein Saveh
    Farhad Tabatabai Ghomsheh
    [J]. BioMedical Engineering OnLine, 16
  • [2] A multi-level drill guide template improves the accuracy of pedicle screw placement in lumbar spine
    Ge, D. -W.
    Yang, L.
    Chen, X.
    Tang, J.
    Chen, H. -T.
    Li, H. -J.
    Sui, T.
    Zhuang, Y.
    Zheng, S. -N.
    Cao, X. -J.
    [J]. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2018, 22 (12) : 3643 - 3648
  • [3] Preliminary application of a multi-level 3D printing drill guide template for pedicle screw placement in severe and rigid scoliosis
    Kun Liu
    Qiang Zhang
    Xin Li
    Changsong Zhao
    Xuemin Quan
    Rugang Zhao
    Zongfeng Chen
    Yansheng Li
    [J]. European Spine Journal, 2017, 26 : 1684 - 1689
  • [4] Preliminary application of a multi-level 3D printing drill guide template for pedicle screw placement in severe and rigid scoliosis
    Liu, Kun
    Zhang, Qiang
    Li, Xin
    Zhao, Changsong
    Quan, Xuemin
    Zhao, Rugang
    Chen, Zongfeng
    Li, Yansheng
    [J]. EUROPEAN SPINE JOURNAL, 2017, 26 (06) : 1684 - 1689
  • [5] A Novel Patient-Specific Navigational Template for Cervical Pedicle Screw Placement
    Lu, Sheng
    Xu, Yong Q.
    Lu, William W.
    Ni, Guo X.
    Li, Yan B.
    Shi, Ji H.
    Li, Dong P.
    Chen, Guo P.
    Chen, Yu B.
    Zhang, Yuan Z.
    [J]. SPINE, 2009, 34 (26) : E959 - E964
  • [6] Accuracy of pedicle screw placement using patient-specific template guide system
    Fujita, Ryo
    Oda, Itaru
    Takeuchi, Hirohito
    Oshima, Shigeki
    Fujiya, Masanori
    Yahara, Yasuhito
    Kawaguchi, Yoshiharu
    [J]. JOURNAL OF ORTHOPAEDIC SCIENCE, 2022, 27 (02) : 348 - 354
  • [7] Rapid prototype patient-specific drill template for cervical pedicle screw placement
    Owen, Brent D.
    Christensen, Gary E.
    Reinhardt, Joseph M.
    Ryken, Timothy C.
    [J]. COMPUTER AIDED SURGERY, 2007, 12 (05) : 303 - 308
  • [8] CLINICAL APPLICATION OF A DRILL GUIDE TEMPLATE FOR PEDICLE SCREW PLACEMENT IN SEVERE SCOLIOSIS
    Li, Xin
    Zhang, Yaoshen
    Zhang, Qiang
    Zhao, Changsong
    Liu, Kun
    [J]. ACTA ORTOPEDICA BRASILEIRA, 2017, 25 (02): : 67 - 70
  • [9] A low invasiveness patient's specific template for spine surgery
    Azimifar, Farhad
    Hassani, Kamran
    Saveh, Amir Hossein
    Tabatabai Ghomshe, Farhad
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2017, 231 (02) : 143 - 148
  • [10] A multi-level rapid prototyping drill guide template reduces the perforation risk of pedicle screw placement in the lumbar and sacral spine
    Merc, Matjaz
    Drstvensek, Igor
    Vogrin, Matjaz
    Brajlih, Tomaz
    Recnik, Gregor
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (07) : 893 - 899