A medium invasiveness multi-level patient's specific template for pedicle screw placement in the scoliosis surgery

被引:12
|
作者
Azimifar, Farhad [1 ]
Hassani, Kamran [1 ]
Saveh, Amir Hossein [2 ]
Ghomsheh, Farhad Tabatabai [3 ]
机构
[1] Islamic Azad Univ, Sci & Res Branch, Dept Biomech, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Shohada Tajrish Neurosurg Comprehens Ctr Excellen, Funct Neurosurg Res Ctr, Tehran, Iran
[3] Univ Social Welf & Rehabil Sci USWR, Ergon Dept, Pediat Neurorehabil Res Ctr, Tehran, Iran
来源
关键词
Multi-level; Template; Spine; Surgery; FREE-HAND TECHNIQUE; DRILL GUIDE TEMPLATE; COMPUTED-TOMOGRAPHY; THORACOLUMBAR SPINE; ROBOTIC GUIDANCE; SACRAL SPINE; LUMBAR SPINE; IN-VIVO; ACCURACY; FLUOROSCOPY;
D O I
10.1186/s12938-017-0421-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Several methods including free-hand technique, fluoroscopic guidance, image-guided navigation, computer-assisted surgery system, robotic platform and patient's specific templates are being used for pedicle screw placement. These methods have screw misplacements and are not always easy to be applied. Furthermore, it is necessary to expose completely a large portions of the spine in order to access fit entirely around the vertebrae. Methods: In this study, a multi-level patient's specific template with medium invasiveness was proposed for pedicle screw placement in the scoliosis surgery. It helps to solve the problems related to the soft tissues removal. After a computer tomography (CT) scan of the spine, the templates were designed based on surgical considerations. Each template was manufactured using three-dimensional printing technology under a semi-flexible post processing. The templates were placed on vertebras at four points-at the base of the superior-inferior articular processes on both left-right sides. This helps to obtain less invasive and more accurate procedure as well as true-stable and easy placement in a unique position. The accuracy of screw positions was confirmed by CT scan after screw placement. Results: The result showed the correct alignment in pedicle screw placement. In addition, the template has been initially tested on a metal wire series Moulage (height 70 cm and material is PVC). The results demonstrated that it could be possible to implement it on a real patient. Conclusions: The proposed template significantly reduced screw misplacements, increased stability, and decreased the sliding & the intervention invasiveness.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Accuracy of a patient-specific template for pedicle screw placement compared with a conventional method: a meta-analysis
    Fan, Yong
    Du, Jin-Peng
    Wu, Qi-Ning
    Zhang, Jia-Nan
    Hao, Ding-Jun
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (12) : 1641 - 1649
  • [22] Accuracy and efficacy of thoracic pedicle screws in scoliosis with patient-specific drill template
    Sheng Lu
    Yuan Z. Zhang
    Zheng Wang
    Ji H. Shi
    Yu B. Chen
    Xing M. Xu
    Yong Q. Xu
    [J]. Medical & Biological Engineering & Computing, 2012, 50 : 751 - 758
  • [23] Accuracy and efficacy of thoracic pedicle screws in scoliosis with patient-specific drill template
    Lu, Sheng
    Zhang, Yuan Z.
    Wang, Zheng
    Shi, Ji H.
    Chen, Yu B.
    Xu, Xing M.
    Xu, Yong Q.
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2012, 50 (07) : 751 - 758
  • [24] The use of CT in the development and implementation of a preoperative protocol to aid in pedicle screw placement during scoliosis surgery
    Douglas Jamieson
    Angeliki Perdios
    Renjit Varghese
    Christopher W. Reilly
    [J]. Pediatric Radiology, 2008, 38 : 452 - 456
  • [25] Reliability of Triggered EMG for Prediction of Safety during Pedicle Screw Placement in Adolescent Idiopathic Scoliosis Surgery
    Min, Woo-Kie
    Lee, Hyun-Joo
    Jeong, Won-Ju
    Oh, Chang-Wug
    Bae, Jae-Sung
    Cho, Hwan-Seong
    Jeon, In-Ho
    Cho, Chang-Hyun
    Park, Byung-Chul
    [J]. ASIAN SPINE JOURNAL, 2011, 5 (01) : 51 - 58
  • [26] The use of CT in the development and implementation of a preoperative protocol to aid in pedicle screw placement during scoliosis surgery
    Jamieson, Douglas
    Perdios, Angeliki
    Varghese, Renjit
    Reilly, Christopher W.
    [J]. PEDIATRIC RADIOLOGY, 2008, 38 (04) : 452 - 456
  • [27] Safe and Accurate Midcervical Pedicle Screw Insertion Procedure With the Patient-Specific Screw Guide Template System
    Kaneyama, Shuichi
    Sugawara, Taku
    Sumi, Masatoshi
    [J]. SPINE, 2015, 40 (06) : E341 - E348
  • [28] Patient specific pedicle screw placement guide for severe spine deformity in VACTERL syndrome
    Cinnella, Pasquale
    Cravino, Mattia
    Girardo, Massimo
    Gargiulo, Giosue
    Masse, Alessandro
    Rava, Alessandro
    [J]. MINERVA ORTHOPEDICS, 2021, 72 (02): : 227 - 232
  • [29] Rapid prototype patient-specific drill templates for cervical pedicle screw placement
    Ryken, TC
    Owen, BD
    Reinhardt, JM
    Christensen, GE
    [J]. JOURNAL OF NEUROSURGERY, 2006, 104 (04) : A640 - A640
  • [30] Patient-specific guide systems decrease the major perforation rate of pedicle screw placement in comparison to the freehand technique for adolescent idiopathic scoliosis
    Maruo, Keishi
    Arizumi, Fumihiro
    Kishima, Kazuya
    Yoshie, Norichika
    Kusukawa, Tomoyuki
    Tachibana, Toshiya
    [J]. EUROPEAN SPINE JOURNAL, 2023, 32 (09) : 3105 - 3112