Electrochemical sensing of levodopa or carbidopa using a glassy carbon electrode modified with carbon nanotubes within a poly(allylamine hydrochloride) film

被引:21
|
作者
Takeda, Humberto Hissashi [1 ]
Silva, Tiago Almeida [2 ]
Janegitz, Bruno Campos [3 ]
Vicentini, Fernando Campanha [4 ]
Capparelli Mattoso, Luiz Henrique [5 ]
Fatibello-Filho, Orlando [2 ]
机构
[1] Fed Univ Rondonia, Interdisciplinary Dept Technol & Sci, BR-76872862 Ariquemes, RO, Brazil
[2] Univ Fed Sao Carlos, Dept Chem, BR-13560970 Sao Carlos, SP, Brazil
[3] Univ Fed Sao Carlos, Dept Nat Sci Math & Educ, BR-13600970 Araras, SP, Brazil
[4] Univ Fed Sao Carlos, Ctr Nat Sci, BR-18290000 Buri, SP, Brazil
[5] Embrapa Instrumentat, Natl Lab Nanotechnol Agribusiness, BR-13560970 Sao Carlos, SP, Brazil
关键词
CROSS-LINKED CHITOSAN; VOLTAMMETRIC DETERMINATION; PARKINSONS-DISEASE; PASTE ELECTRODE; L-DOPA; ASCORBIC-ACID; PHARMACEUTICAL FORMULATIONS; BIOLOGICAL SAMPLES; URIC-ACID; DISPERSION;
D O I
10.1039/c5ay03041b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, the performance of a glassy carbon electrode (GCE) modified with functionalized multi-walled carbon nanotubes (MWCNT) immobilized within a poly(allylamine hydrochloride) (PAH) film for the electrochemical determination of the catecholamines, levodopa (LD) and carbidopa (CD) is evaluated. The electrochemical behaviour of the MWCNT-PAH/GCE sensor was investigated via cyclic voltammetry. Under the optimum experimental conditions, the LD and CD analytes were determined by differential pulse voltammetry (DPV) using their oxidation redox processes at -24 mV and +490 mV (versus Ag/AgCl (3.0 mol L-1 KCl)), respectively. The obtained analytical curves were linear from 2.0 to 27 mu mol L-1 for LD and from 2.0 to 23 mu mol L-1 for CD, with limits of detection of 0.84 mu mol L-1 for LD and 0.65 mu mol L-1 for CD. The proposed DPV method was successfully employed for LD and CD determination in commercial pharmaceutical formulation samples, and the collected results were consistent with those obtained by the respective standard methods at a confidence level of 95%. In addition, the potentiality of the DPV method was tested for LD and CD quantification in human serum samples.
引用
收藏
页码:1274 / 1280
页数:7
相关论文
共 50 条
  • [1] Glassy Carbon Electrode Modified with Functionalized Carbon Nanotubes Within a Poly(allylamine hydrochloride) Film for the Voltammetric Determination of Sulfite in Foods
    Sartori, Elen Romao
    Takeda, Humberto Hissashi
    Fatibello-Filho, Orlando
    ELECTROANALYSIS, 2011, 23 (11) : 2526 - 2533
  • [2] Voltammetric determination of verapamil and propranolol using a glassy carbon electrode modified with functionalized multiwalled carbon nanotubes within a poly (allylamine hydrochloride) film
    Oliveira, Geiser Gabriel
    Azzi, Deborah Christine
    Vicentini, Fernando Campanha
    Sartori, Elen Romao
    Fatibello-Filho, Orlando
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 708 : 73 - 79
  • [3] Differential pulse voltammetric determination of ciprofibrate in pharmaceutical formulations using a glassy carbon electrode modified with functionalized carbon nanotubes within a poly(allylamine hydrochloride) film
    Takeda, Humberto H.
    Janegitz, Bruno C.
    Medeiros, Roberta A.
    Mattoso, Luiz H. C.
    Fatibello-Filho, Orlando
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01): : 755 - 760
  • [4] Simultaneous Voltammetric Determination of Ascorbic Acid and Sulfite in Beverages Employing a Glassy Carbon Electrode Modified with Carbon Nanotubes within a Poly(Allylamine Hydrochloride) Film
    Sartori, Elen Romao
    Fatibello-Filho, Orlando
    ELECTROANALYSIS, 2012, 24 (03) : 627 - 634
  • [5] Simultaneous determination of Levodopa and Carbidopa in pharmaceutical tablets using functionalized multiwall carbon nanotubes modified glassy carbon electrode
    ALOthman, Zeid A.
    Wabaidur, Saikh M.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 239
  • [6] Indirect determination of sulfite using a polyphenol oxidase biosensor based on a glassy carbon electrode modified with multi-walled carbon nanotubes and gold nanoparticles within a poly(allylamine hydrochloride) film
    Sartori, Elen Romao
    Vicentini, Fernando Campanha
    Fatibello-Filho, Orlando
    TALANTA, 2011, 87 : 235 - 242
  • [7] Glassy Carbon Electrode Modified with Layering of Carbon Black/Poly(Allylamine Hydrochloride) Composite for Multianalyte Determination
    Scremin, Jessica
    Mattos, Gabriel J.
    Crapnell, Robert D.
    Rowley-Neale, Samuel J.
    Banks, Craig E.
    Sartori, Elen R.
    ELECTROANALYSIS, 2021, 33 (02) : 526 - 536
  • [8] Electrochemical Sensing of Theophylline using Modified Glassy Carbon Electrode
    Pour, Effat Sharifi
    Ebrahimi, Maryam
    Beitollahi, Hadi
    CHEMICAL METHODOLOGIES, 2022, 6 (07): : 560 - 568
  • [9] Electrochemical investigation of a glassy carbon electrode modified with carbon nanotubes decorated with (poly)crystalline gold
    Antonio Radoi
    Simona-Carmen Litescu
    Sandra A. V. Eremia
    Mihaela Miu
    Mihai Danila
    Adrian Dinescu
    Gabriel-Lucian Radu
    Microchimica Acta, 2011, 175 : 97 - 104
  • [10] Electrochemical investigation of a glassy carbon electrode modified with carbon nanotubes decorated with (poly)crystalline gold
    Radoi, Antonio
    Litescu, Simona-Carmen
    Eremia, Sandra A. V.
    Miu, Mihaela
    Danila, Mihai
    Dinescu, Adrian
    Radu, Gabriel-Lucian
    MICROCHIMICA ACTA, 2011, 175 (1-2) : 97 - 104