Voltammetric determination of verapamil and propranolol using a glassy carbon electrode modified with functionalized multiwalled carbon nanotubes within a poly (allylamine hydrochloride) film

被引:52
|
作者
Oliveira, Geiser Gabriel [1 ]
Azzi, Deborah Christine [1 ]
Vicentini, Fernando Campanha [1 ]
Sartori, Elen Romao [1 ,2 ]
Fatibello-Filho, Orlando [1 ,3 ]
机构
[1] Univ Fed Sao Carlos, Dept Quim, BR-13560970 Sao Carlos, SP, Brazil
[2] Univ Estadual Londrina, Dept Quim, BR-86057970 Londrina, PR, Brazil
[3] Inst Nacl Ciencias & Tecnol Bioanalit, BR-13083970 Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Verapamil determination; Propranolol determination; Voltammetry; Modified electrode; Multiwalled carbon nanotubes; Poly (allylamine hydrochloride); SOLID-PHASE EXTRACTION; POLY(ALLYLAMINE HYDROCHLORIDE); PHARMACEUTICAL FORMULATIONS; SPECTROPHOTOMETRIC DETERMINATION; ELECTROCHEMICAL-BEHAVIOR; PASTE ELECTRODE; HUMAN PLASMA; GRAPHITE; SULFITE; LIQUID;
D O I
10.1016/j.jelechem.2013.09.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this report, we describe the individual determination of verapamil (VPM) and propranolol (PROP) in pharmaceutical formulations using square-wave adsorptive anodic stripping voltammetry (SWAdASV), differential-pulse adsorptive anodic stripping voltammetry (DPAdASV), and a glassy carbon electrode modified with functionalized multiwalled carbon nanotubes within a poly (allylamine hydrochloride) film. The anodic peak potential for VPM and PROP at this modified electrode was 1.09 V and 0.930 V (versus Ag/AgCI (3.0 mol L-1 KCI)), respectively, in a 0.25 mol L-1 H2SO4 solution. Under optimized SWAdASV and DPAdASV conditions, the obtained analytical curves were linear for VPM concentrations ranging from 5.0 x 10(-9) to 1.1 x 10(-7) mol L-1, and PROP concentrations ranging from 7.4 x 10(-8) to 1.0 x 10(-6) mol L-1, with detection limits of 3.6 x 10(-9) mol L-1 and 2.6 x 10(-8) mol L-1, respectively. Both of the proposed methods were successfully applied for the individual determination of VPM and PROP in several pharmaceutical formulations. The results were in a close agreement with a 95% confidence level for those obtained using official spectrophotometric methods. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:73 / 79
页数:7
相关论文
共 50 条
  • [1] Glassy Carbon Electrode Modified with Functionalized Carbon Nanotubes Within a Poly(allylamine hydrochloride) Film for the Voltammetric Determination of Sulfite in Foods
    Sartori, Elen Romao
    Takeda, Humberto Hissashi
    Fatibello-Filho, Orlando
    [J]. ELECTROANALYSIS, 2011, 23 (11) : 2526 - 2533
  • [2] Differential pulse voltammetric determination of ciprofibrate in pharmaceutical formulations using a glassy carbon electrode modified with functionalized carbon nanotubes within a poly(allylamine hydrochloride) film
    Takeda, Humberto H.
    Janegitz, Bruno C.
    Medeiros, Roberta A.
    Mattoso, Luiz H. C.
    Fatibello-Filho, Orlando
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01): : 755 - 760
  • [3] Simultaneous Voltammetric Determination of Ascorbic Acid and Sulfite in Beverages Employing a Glassy Carbon Electrode Modified with Carbon Nanotubes within a Poly(Allylamine Hydrochloride) Film
    Sartori, Elen Romao
    Fatibello-Filho, Orlando
    [J]. ELECTROANALYSIS, 2012, 24 (03) : 627 - 634
  • [4] Electrochemical sensing of levodopa or carbidopa using a glassy carbon electrode modified with carbon nanotubes within a poly(allylamine hydrochloride) film
    Takeda, Humberto Hissashi
    Silva, Tiago Almeida
    Janegitz, Bruno Campos
    Vicentini, Fernando Campanha
    Capparelli Mattoso, Luiz Henrique
    Fatibello-Filho, Orlando
    [J]. ANALYTICAL METHODS, 2016, 8 (06) : 1274 - 1280
  • [5] Adsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes
    Khodadadian, Mehdi
    Jalili, Ronak
    Bahrami, Mohammad Taher
    Bahrami, Gholamreza
    [J]. IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH, 2017, 16 (04): : 1312 - 1319
  • [6] Voltammetric Determination of Sulfonamides with a Modified Glassy Carbon Electrode Using Carboxyl Multiwalled Carbon Nanotubes
    He, Bao-Shan
    Chen, Wen-Bo
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2016, 27 (12) : 2216 - 2225
  • [7] Square-wave voltammetric determination of paraquat using a glassy carbon electrode modified with multiwalled carbon nanotubes within a dihexadecylhydrogenphosphate (DHP) film
    Costa Garcia, Livia Luiza
    Soares Figueiredo-Filho, Luiz Carlos
    Oliveira, Geiser Gabriel
    Fatibello-Filho, Orlando
    Banks, Craig E.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 181 : 306 - 311
  • [8] Sensitive voltammetric determination of paracetamol by poly (4-vinylpyridine)/multiwalled carbon nanotubes modified glassy carbon electrode
    Ghadimi, Hanieh
    Tehrani, Ramin M. A.
    Ali, Abdussalam Salhin Mohamed
    Mohamed, Norita
    Ab Ghani, Sulaiman
    [J]. ANALYTICA CHIMICA ACTA, 2013, 765 : 70 - 76
  • [9] Poly(allylamine hydrochloride) Functionalized Multiwalled Carbon Nanotube Modified Carbon Paste Electrode as Acetylcholinesterase Biosensor Transducer
    Cevik, Serdar
    Timur, Suna
    Anik, Ulku
    [J]. ELECTROANALYSIS, 2013, 25 (10) : 2377 - 2383
  • [10] Glassy Carbon Electrode Modified with Layering of Carbon Black/Poly(Allylamine Hydrochloride) Composite for Multianalyte Determination
    Scremin, Jessica
    Mattos, Gabriel J.
    Crapnell, Robert D.
    Rowley-Neale, Samuel J.
    Banks, Craig E.
    Sartori, Elen R.