Electrochemical sensing of levodopa or carbidopa using a glassy carbon electrode modified with carbon nanotubes within a poly(allylamine hydrochloride) film

被引:21
|
作者
Takeda, Humberto Hissashi [1 ]
Silva, Tiago Almeida [2 ]
Janegitz, Bruno Campos [3 ]
Vicentini, Fernando Campanha [4 ]
Capparelli Mattoso, Luiz Henrique [5 ]
Fatibello-Filho, Orlando [2 ]
机构
[1] Fed Univ Rondonia, Interdisciplinary Dept Technol & Sci, BR-76872862 Ariquemes, RO, Brazil
[2] Univ Fed Sao Carlos, Dept Chem, BR-13560970 Sao Carlos, SP, Brazil
[3] Univ Fed Sao Carlos, Dept Nat Sci Math & Educ, BR-13600970 Araras, SP, Brazil
[4] Univ Fed Sao Carlos, Ctr Nat Sci, BR-18290000 Buri, SP, Brazil
[5] Embrapa Instrumentat, Natl Lab Nanotechnol Agribusiness, BR-13560970 Sao Carlos, SP, Brazil
关键词
CROSS-LINKED CHITOSAN; VOLTAMMETRIC DETERMINATION; PARKINSONS-DISEASE; PASTE ELECTRODE; L-DOPA; ASCORBIC-ACID; PHARMACEUTICAL FORMULATIONS; BIOLOGICAL SAMPLES; URIC-ACID; DISPERSION;
D O I
10.1039/c5ay03041b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, the performance of a glassy carbon electrode (GCE) modified with functionalized multi-walled carbon nanotubes (MWCNT) immobilized within a poly(allylamine hydrochloride) (PAH) film for the electrochemical determination of the catecholamines, levodopa (LD) and carbidopa (CD) is evaluated. The electrochemical behaviour of the MWCNT-PAH/GCE sensor was investigated via cyclic voltammetry. Under the optimum experimental conditions, the LD and CD analytes were determined by differential pulse voltammetry (DPV) using their oxidation redox processes at -24 mV and +490 mV (versus Ag/AgCl (3.0 mol L-1 KCl)), respectively. The obtained analytical curves were linear from 2.0 to 27 mu mol L-1 for LD and from 2.0 to 23 mu mol L-1 for CD, with limits of detection of 0.84 mu mol L-1 for LD and 0.65 mu mol L-1 for CD. The proposed DPV method was successfully employed for LD and CD determination in commercial pharmaceutical formulation samples, and the collected results were consistent with those obtained by the respective standard methods at a confidence level of 95%. In addition, the potentiality of the DPV method was tested for LD and CD quantification in human serum samples.
引用
收藏
页码:1274 / 1280
页数:7
相关论文
共 50 条
  • [31] Electrochemical Sensing of Uric Acid Using Glassy Carbon Modified with Multiwall Carbon Nanotubes Dispersed in Polyethylenimine
    Gutierrez, Alejandro
    Lozano, Maria L.
    Galicia, Laura
    Ferreyra, Nancy F.
    Rivas, Gustavo A.
    ELECTROANALYSIS, 2014, 26 (10) : 2191 - 2196
  • [32] Simultaneous determination of levodopa and tryptophan using a modified glassy carbon electrode
    Aflatoonian, Mohammad Reza
    Tajik, Somayeh
    Aflatoonian, Behnaz
    Ekrami-Kakhki, Mehri-Saddat
    Divsalar, Kouros
    Shoaie, Iran Sheikh
    Dourandish, Zahra
    Sheikhshoaie, Mahdieh
    EURASIAN CHEMICAL COMMUNICATIONS, 2020, 2 (04): : 505 - 515
  • [33] Electrochemical determination of diphenols and their mixtures at the multiwall carbon nanotubes/poly (3-methylthiophene) modified glassy carbon electrode
    Zhang, He
    Zhao, Jinsheng
    Liu, Houting
    Liu, Renmin
    Wang, Huaisheng
    Liu, Jifeng
    MICROCHIMICA ACTA, 2010, 169 (3-4) : 277 - 282
  • [34] Electrochemical Determination of Bisphenol A at Multi-walled Carbon Nanotubes/Poly (Crystal Violet) Modified Glassy Carbon Electrode
    Wang, Wei
    Tang, Jing
    Zheng, Shengbiao
    Ma, Xiaoqing
    Zhu, Jinkun
    Li, Feiyue
    Wang, Jianfei
    FOOD ANALYTICAL METHODS, 2017, 10 (12) : 3815 - 3824
  • [35] Electrochemical Determination of Bisphenol A at Multi-walled Carbon Nanotubes/Poly (Crystal Violet) Modified Glassy Carbon Electrode
    Wei Wang
    Jing Tang
    Shengbiao Zheng
    Xiaoqing Ma
    Jinkun Zhu
    Feiyue Li
    Jianfei Wang
    Food Analytical Methods, 2017, 10 : 3815 - 3824
  • [36] Electrochemical determination of diphenols and their mixtures at the multiwall carbon nanotubes/poly (3-methylthiophene) modified glassy carbon electrode
    He Zhang
    Jinsheng Zhao
    Houting Liu
    Renmin Liu
    Huaisheng Wang
    Jifeng Liu
    Microchimica Acta, 2010, 169 : 277 - 282
  • [37] Direct electron transfer of glucose oxidase at glassy carbon electrode modified with functionalized carbon nanotubes within a dihexadecylphosphate film
    Janegitz, Bruno C.
    Pauliukaite, Rasa
    Ghica, Mariana E.
    Brett, Christopher M. A.
    Fatibello-Filho, Orlando
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 158 (01) : 411 - 417
  • [38] Poly(allylamine hydrochloride) Functionalized Multiwalled Carbon Nanotube Modified Carbon Paste Electrode as Acetylcholinesterase Biosensor Transducer
    Cevik, Serdar
    Timur, Suna
    Anik, Ulku
    ELECTROANALYSIS, 2013, 25 (10) : 2377 - 2383
  • [39] Quantification of methyldopa in pharmaceuticals using a glassy carbon electrode modified with carbon nanotubes
    Kutluay, Aysegul
    Aslanoglu, Mehmet
    CHINESE CHEMICAL LETTERS, 2016, 27 (01) : 91 - 95
  • [40] Quantification of methyldopa in pharmaceuticals using a glassy carbon electrode modified with carbon nanotubes
    Aysegul Kutluay
    Mehmet Aslanoglu
    Chinese Chemical Letters, 2016, 27 (01) : 91 - 95