Do Stem Taper Microgrooves Influence Taper Corrosion in Total Hip Arthroplasty? A Matched Cohort Retrieval Study

被引:30
|
作者
Arnholt, Christina M. [1 ]
MacDonald, Daniel W. [1 ]
Underwood, Richard J. [2 ]
Guyer, Eric P. [3 ]
Rimnac, Clare M. [4 ]
Kurtz, Steven M. [1 ,2 ]
Mont, Michael A. [5 ]
Klein, Gregg R. [6 ]
Lee, Gwo-Chin [7 ]
Chen, Antonia F. [8 ]
Hamlin, Brian R. [9 ]
Cates, Harold E. [10 ]
Malkani, Arthur L. [11 ,12 ]
Kraay, Matthew J. [4 ]
机构
[1] Drexel Univ, Implant Res Ctr, 3401 Market St,Suite 345, Philadelphia, PA 19104 USA
[2] Exponent Inc, Philadelphia, PA USA
[3] Exponent Inc, Atlanta, GA USA
[4] Case Western Reserve Univ, Ctr Evaluat Implant Performance, Cleveland, OH 44106 USA
[5] Sinai Hosp Baltimore, Baltimore, MD USA
[6] Hartzband Ctr Hip & Knee Replacement, Paramus, NJ USA
[7] Univ Penn Hlth Syst, Presbyterian Med Ctr, Philadelphia, PA USA
[8] Thomas Jefferson Univ Hosp, Rothman Inst, Philadelphia, PA 19107 USA
[9] Univ Pittsburgh, Med Ctr, Pittsburgh, PA USA
[10] Tennessee Orthopaed Clin, Knoxville, TN USA
[11] Jewish Hosp, Louisville, KY USA
[12] St Marys Hlth Care, Louisville, KY USA
来源
JOURNAL OF ARTHROPLASTY | 2017年 / 32卷 / 04期
关键词
mechanically assisted crevice corrosion; fretting; corrosion; taper; microgrooves; ON-METAL BEARINGS; SURFACE-TOPOGRAPHY; FAILURE; NECK; REPLACEMENTS; MODULARITY; TRUNNIONS; IMPLANTS; JUNCTION; WEAR;
D O I
10.1016/j.arth.2016.11.018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Previous studies identified imprinting of the stem morphology onto the interior head bore, leading researchers to hypothesize an influence of taper topography on mechanically assisted crevice corrosion. The purpose of this study was to analyze whether microgrooved stem tapers result in greater fretting corrosion damage than smooth stem tapers. Methods: A matched cohort of 120 retrieved head-stem pairs from metal-on-polyethylene bearings was created controlling for implantation time, flexural rigidity, apparent length of engagement, and head size. There were 2 groups of 60 heads each, mated with either smooth or microgrooved stem tapers. A high-precision roundness machine was used to measure and categorize the surface morphology. Fretting corrosion damage at the head-neck junction was characterized using the Higgs-Goldberg scoring method. Fourteen of the most damaged heads were analyzed for the maximum depth of material loss and focused ion beam cross-sectioned to view oxide and base metal. Results: Fretting corrosion damage was not different between the 2 cohorts at the femoral head (P = .14, Mann-Whitney) or stem tapers (P = .35). There was no difference in the maximum depths of material loss between the cohorts (P = .71). Cross-sectioning revealed contact damage, signs of micro-motion, and chromium-rich oxide layers in both cohorts. Microgroove imprinting did not appear to have a different effect on the fretting corrosion behavior. Conclusion: The results of this matched cohort retrieval study do not support the hypothesis that taper surfaces with microgrooved stems exhibit increased in vivo fretting corrosion damage or material release. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:1363 / 1373
页数:11
相关论文
共 50 条
  • [41] Single-taper conical tapered stem in total hip arthroplasty for developmental dysplasia of the hip: A long-term evaluation
    Castagnini, Francesco
    Bordini, Barbara
    Cosentino, Monica
    Basile, Tommaso
    Giardina, Federico
    Traina, Francesco
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2023, 109 (07)
  • [42] Flexural Rigidity, Taper Angle, and Contact Length Affect Fretting of the Femoral Stem Trunnion in Total Hip Arthroplasty
    Kao, Ying-Ying J.
    Koch, Chelsea N.
    Wright, Timothy M.
    Padgett, Douglas E.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (09): : S254 - S258
  • [43] NUMERICAL ANALYSIS ON THE INFLUENCE OF TAPER JUNCTION CORROSION PROFILE WITH EMPHASIS ON TI-ALLOY MODULAR HIP ARTHROPLASTY
    Novotny, Adam
    Paliwal, Manish
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2017, VOL 3, 2018,
  • [44] Differences in peri-hip articular pain after total hip arthroplasty between taper wedge stem and fit-and-fill stem
    Kato, Daisaku
    Takegami, Yasuhiko
    Seki, Taisuke
    Osawa, Yusuke
    Takemoto, Genta
    Okamoto, Masanori
    Iida, Hiroki
    Imagama, Shiro
    JOURNAL OF ORTHOPAEDICS, 2023, 35 : 58 - 63
  • [45] Primary hip replacement stem taper fracture due to corrosion in 3 patients
    Morlock, Michael M.
    Buente, Dennis
    Ettema, Harmen
    Verheyen, Cees C.
    Hamberg, Ake
    Gilbert, Jeremy
    ACTA ORTHOPAEDICA, 2016, 87 (02) : 189 - 192
  • [46] Letter to the Editor: In Response to "Modular Taper Junction Corrosion and Failure: How to Approach a Recalled Total Hip Arthroplasty Implant"
    Davies, Joseph F.
    Leone, William A.
    Nessler, Joseph P.
    Perona, Paul G.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (02): : 449 - 450
  • [47] Volumetric material loss in metal-on-metal total hip arthroplasty: Bearing surface wear versus taper corrosion
    Hexter, A.
    Matthies, A.
    Bills, P.
    Skinner, J.
    Hart, A.
    BRITISH JOURNAL OF SURGERY, 2013, 100 : 42 - 42
  • [48] Clinically significant corrosion at the head-neck taper interface in total hip arthroplasty: a systematic review and case series
    Carli, Alberto
    Politis, Angelos
    Zukor, David
    Huk, Olga
    Antoniou, John
    HIP INTERNATIONAL, 2015, 25 (01) : 7 - 14
  • [49] The incidence of adverse local tissue reaction due to head taper corrosion after total hip arthroplasty using V40 taper and 36 mm CoCr head
    Grothe, T.
    Guenther, K-P.
    Hartmann, A.
    Blum, S.
    Haselhoff, R.
    Goronzy, J.
    BONE & JOINT JOURNAL, 2022, 104B (07): : 852 - 858
  • [50] Effect of surface topography and residual stress on the taper connection stability in total hip arthroplasty
    Mai, Phuong Thao
    Bormann, Therese
    Mueller, Ulrike
    Kretzer, Jan Philippe
    Gibmeier, Jens
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 128