Absolute, high-accuracy characterization of a variable line spacing grating for the European XFEL soft X-ray monochromator

被引:3
|
作者
Vannoni, Maurizio [1 ]
Freijo-Martin, Idoia [1 ]
机构
[1] European XFEL GmbH, Holzkoppel 4, D-22869 Schenefeld, Germany
来源
OPTICS EXPRESS | 2017年 / 25卷 / 22期
关键词
3-FLAT TEST; ITERATIVE ALGORITHM; CALIBRATION; PLANARITY;
D O I
10.1364/OE.25.026519
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The European XFEL is a free-electron laser (FEL) with a superconducting linear accelerator and three beamlines (SASE1, SASE2, and SASE3) covering the energy range from 250 eV to 24 keV. The SASE3 beamline is dedicated to the soft x-ray range (0.25-3 keV) and is designed to operate in both monochromatic and non-monochromatic mode. A variable line spacing - plane grating (VLS-PG) monochromator is placed along the beam transport system for the monochromatic mode. The VLS parameters of the grating profile are challenging from a manufacturing and measuring perspective, especially at the desired length of 530 mm. A shorter grating of 150 mm has been procured to allow early operation of the facility. We describe the characterization method that was used to assess the VLS parameters of the grating using Fizeau interferometry. The method is intrinsically absolute and limited only by the quality of the test grating and the noise level. Further measurements using a white-light-interferometry profilometer are also reported. We discuss the possibility of extending the method to the future 530 mm long grating. (C) 2017 Optical Society of America
引用
收藏
页码:26519 / 26526
页数:8
相关论文
共 50 条
  • [21] High-accuracy x-ray line standards in the 3-keV region
    Schlesser, S.
    Boucard, S.
    Covita, D. S.
    dos Santos, J. M. F.
    Fuhrmann, H.
    Gotta, D.
    Gruber, A.
    Hennebach, M.
    Hirtl, A.
    Indelicato, P.
    Le Bigot, E. -O.
    Simons, L. M.
    Stingelin, L.
    Trassinelli, M.
    Veloso, J. F. C. A.
    Wasser, A.
    Zmeskal, J.
    PHYSICAL REVIEW A, 2013, 88 (02):
  • [22] Commissioning of a photoelectron spectrometer for soft X-ray photon diagnostics at the European XFEL
    Laksman, Joakim
    Buck, Jens
    Glaser, Leif
    Planas, Marc
    Dietrich, Florian
    Liu, Jia
    Maltezopoulos, Theophilos
    Scholz, Frank
    Seltmann, Joern
    Hartmann, Gregor
    Ilchen, Markus
    Freund, Wolfgang
    Kujala, Naresh
    Viefhaus, Jens
    Gruenert, Jan
    JOURNAL OF SYNCHROTRON RADIATION, 2019, 26 : 1010 - 1016
  • [23] Design of a holographically recorded plane crating with a varied line spacing for a soft X-ray grazing-incidence monochromator
    Amemiya, K
    Kitajima, Y
    Ohta, T
    Ito, K
    JOURNAL OF SYNCHROTRON RADIATION, 1996, 3 : 282 - 288
  • [24] High-accuracy x-ray foil optic assembly
    Monnelly, GP
    Mongrard, O
    Breslau, D
    Butler, N
    Chen, CG
    Cohen, L
    Gu, W
    Heilmann, RK
    Konkola, PT
    Ricker, GR
    Schattenburg, ML
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS IV, 2000, 4138 : 164 - 173
  • [25] Structure design and accuracy testing of monochromator in a soft X-ray spectromicroscopic beamline
    Lu, Q. (luqipeng@126.com), 1600, Chinese Optical Society (33):
  • [26] Development of high-accuracy X-ray ptychography apparatus
    Suzuki, Akihiro
    Senba, Yasunori
    Ohashi, Haruhiko
    Kohmura, Yoshiki
    Yamauchi, Kazuto
    Ishikawa, Tetsuya
    Takahashi, Yukio
    11TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY (XRM2012), 2013, 463
  • [27] High-accuracy X-ray detector calibration at PTB
    Krumrey, M
    Scholze, F
    Ulm, G
    HIGH-ENERGY DETECTORS IN ASTRONOMY, 2004, 5501 : 277 - 285
  • [28] ABSOLUTE SOFT X-RAY MEASUREMENTS WITH A TRANSMISSION GRATING SPECTROMETER.
    Eidmann, K.
    Kishimoto, T.
    Herrmann, P.
    Mizui, J.
    Pakula, R.
    Sigel, R.
    Witkowski, S.
    Laser and Particle Beams, 1985, 4 (pt 3-4) : 521 - 530
  • [29] DESIGN STUDY OF A HIGH-RESOLUTION SOFT-X-RAY MONOCHROMATOR WITH A MOVABLE VARIABLE GROOVE DENSITY GRATING
    HOCHST, H
    BISSEN, M
    ENGELHARDT, MA
    CROSSLEY, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 319 (1-3): : 121 - 127
  • [30] X-RAY MONOCHROMATOR FOR ULTRA-SOFT RADIATION WITH THE RECORDING OF THE ABSOLUTE NUMBER OF QUANTA
    LUKIRSKY, AP
    RUMSH, MA
    SMIRNOV, LA
    OPTIKA I SPEKTROSKOPIYA, 1960, 9 (04): : 505 - 510