Structure design and accuracy testing of monochromator in a soft X-ray spectromicroscopic beamline

被引:0
|
作者
机构
[1] Gong, Xuepeng
[2] Lu, Qipeng
[3] Peng, Zhongqi
来源
Lu, Q. (luqipeng@126.com) | 1600年 / Chinese Optical Society卷 / 33期
关键词
Mirrors; -; Synchrotrons; Monochromators; Mechanisms;
D O I
10.3788/AOS201333.0234001
中图分类号
学科分类号
摘要
In order to satisfy the technical requirement of soft X-ray microscopy beamline in Shanghai Synchrotron Radiation Facility (SSRF), whose key assembly monochromator is designed. Wavelength scanning movement principle of monochromator is described. Design scheme of wavelength scanning mechanism is discussed, and factors affecting the angular repeatability of plane mirror and plane grating are analyzed in detail; switching mechanism of plane grating is described, and horizontal deviation, vertical deviation, roll angle precision, yaw angle precision and pitch angle precision are analyzed in detail; six-bar parallel mechanism is used for adjusting the UHV-chamber, and adjusting range and resolution of the bar are analyzed. The entire structure of monochromator is presented, and its precision testing is performed. Results show that the angular repeatability of plane mirror and plane grating are 0.166″ and 0.149″, and roll, yaw and pitch angular repeatability of plane grating switching mechanism are 0.08″, 0.12″ and 0.05″, indicating that structure design and precision of monochromator satisfy the technical demand.
引用
收藏
相关论文
共 50 条
  • [1] The soft X-ray monochromator at the SASE3 beamline of the European XFEL: from design to operation
    Gerasimova, N.
    La Civita, D.
    Samoylova, L.
    Vannoni, M.
    Villanueva, R.
    Hickin, D.
    Carley, R.
    Gort, R.
    Van Kuiken, B. E.
    Miedema, P.
    Le Guyarder, L.
    Mercadier, L.
    Mercurio, G.
    Schlappa, J.
    Teichman, M.
    Yaroslavtsev, A.
    Sinn, H.
    Scherz, A.
    JOURNAL OF SYNCHROTRON RADIATION, 2022, 29 (Pt 5) : 1299 - 1308
  • [2] Mechanical design and performance evaluation for plane grating monochromator in a soft X-ray microscopy beamline at SSRF
    Gong, Xuepeng
    Lu, Qipeng
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2015, 23 (04) : 409 - 421
  • [3] THE DESIGN AND PERFORMANCE OF A SOFT-X-RAY DOUBLE CRYSTAL MONOCHROMATOR BEAMLINE AT ALADDIN
    YANG, BX
    MIDDLETON, FH
    OLSSON, BG
    BANCROFT, GM
    CHEN, JM
    SHAM, TK
    TAN, K
    WALLACE, DJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 316 (2-3): : 422 - 436
  • [4] Comparative monochromator studies for a soft x-ray microfocus beamline for BESSY-II
    Weiss, MR
    Follath, R
    Senf, F
    Gudat, W
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1999, 101 : 1003 - 1012
  • [5] A high-performance double-crystal monochromator soft X-ray beamline
    Dann, TE
    Chung, SC
    Huang, LJ
    Juang, JM
    Chen, CI
    Tsang, KL
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 664 - 666
  • [6] Design of a monochromator with varied line space plane gratings for a soft X-ray undulator beamline of SPring-8
    Ishiguro, E
    Ohashi, H
    Lu, LJ
    Watari, W
    Kamizato, M
    Ishikawa, T
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1999, 101 : 979 - 984
  • [7] Design of a monochromator with varied line space plane gratings for a soft X-ray undulator beamline of SPring-8
    Ishiguro, E.
    Ohashi, H.
    Lu, Li-jun
    Watari, W.
    Kamizato, M.
    Ishikawa, T.
    Journal of Electron Spectroscopy and Related Phenomena, 101 : 979 - 984
  • [8] A soft X-ray (300-1000 eV) active grating monochromator beamline at NSRRC
    Fung, H. S.
    Yuh, J. Y.
    Huang, L. J.
    Tseng, T. C.
    Perng, S. Y.
    Wang, D. J.
    Tsang, K. L.
    Chung, S. C.
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 563 - +
  • [9] Commissioning of the Spherical Grating Monochromator soft x-ray spectroscopy beamline at the Canadian Light Source
    Regier, T.
    Paulsen, J.
    Wright, G.
    Coulthard, I.
    Tan, K.
    Sham, T. K.
    Blyth, R. I. R.
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 473 - +
  • [10] Performance of the soft x-ray double crystal monochromator on beamline 4.2 at the SRS, Daresbury Laboratory
    Robinson, A.W.
    D'Addato, S.
    Dhanak, V.R.
    Finetti, P.
    Thornton, G.
    Review of Scientific Instruments, 1995, 66 (2 pt 2):