Variability and Repeatability of Quantitative, Fourier-Domain Optical Coherence Tomography Doppler Blood Flow in Young and Elderly Healthy Subjects

被引:18
|
作者
Tayyari, Faryan [1 ]
Yusof, Firdaus [1 ,2 ]
Vymyslicky, Michal [1 ]
Tan, Ou [3 ]
Huang, David [3 ]
Flanagan, John G. [1 ,4 ]
Hudson, Christopher [1 ,4 ]
机构
[1] Univ Waterloo, Sch Optometry & Vis Sci, Retina Res Grp, Waterloo, ON N2L 3G1, Canada
[2] Int Islamic Univ Malaysia, Dept Optometry & Visual Sci, Bandar Indera Mahkota, Kuantan, Malaysia
[3] Oregon Hlth & Sci Univ, Casey Eye Inst, Portland, OR 97201 USA
[4] Univ Toronto, Dept Ophthalmol & Visual Sci, Toronto, ON, Canada
关键词
total retinal blood flow; Fourier-domain optical coherence tomography; repeatability; variability; retinal blood flow; OPEN-ANGLE GLAUCOMA; THREATENING DIABETIC-RETINOPATHY; RETINAL ARTERIOLAR; VASCULAR DYSREGULATION; OCULAR HYPERTENSION; NERVE HEAD; VELOCITY; PROVOCATION; CAFFEINE;
D O I
10.1167/iovs.14-14430
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. The purpose of this study was to determine the within-session variability and between-session repeatability of spectral Fourier-domain optical coherence tomography (Doppler FD-OCT) Doppler retinal blood flow measurements in young and elderly subjects. METHODS. Doppler FD-OCT blood flow was measured using the RTVue system. One eye of each of 20 healthy young (24.7 +/- 2.7 years) and 16 healthy elderly (64.6 +/- 5.1 years) subjects was randomly selected, and the pupil was dilated. The double circular scanning pattern of the RTVue was employed. Six Doppler FD-OCT measurements (i.e., each separate measurement comprising an upper and a lower nasal pupil scan) were acquired at each session. Measurements were repeated approximately 2 weeks later. Total retinal blood flow was calculated by summing flow from all detectable venules surrounding the optic nerve head. The coefficient of variation (COV) and coefficient of repeatability (COR) were calculated for each individual. RESULTS. The individual COVs for retinal blood flow for young subjects ranged from 0.4% to 20.4% (median 7.5%) and for the elderly subjects ranged from 0.6% to 34.6% (median 9.2%). The group mean CORs for retinal blood flow for young participants were 6.4 mu L/min (median 5.91 mu L/min, relative to a mean effect 39.8 mu L/min) and for elderly subjects were 10.5 mu L/min (median 9.2 mu L/min, relative to a mean effect 46.4 mu L/min). CONCLUSIONS. Doppler FD-OCT gave consistent and repeatable blood flow measurements within retinal venules in normal subjects. Considering the individual variation in blood flow measurements, confidence limits for retinal hemodynamics need to be determined on an individual basis.
引用
收藏
页码:7716 / 7725
页数:10
相关论文
共 50 条
  • [1] Investigation of Retinal Blood Flow in Normal and Glaucoma Subjects by Doppler Fourier-Domain Optical Coherence Tomography
    Wang, Yimin
    Tan, Ou
    Huang, David
    [J]. OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIII, 2009, 7168
  • [2] Quantitative Analysis of Retinal Blood Flow in Normal and Glaucoma by Doppler Fourier-Domain Optical Coherence Tomography
    Srinivas, Sowmya
    Nittala, Muneeswar Gupta
    Tan, Ou
    Varma, Rohit
    Francis, Brian A.
    Greenfield, David S.
    Parrish, Richard K.
    Schuman, Joel S.
    Sadda, Srinivas R.
    Huang, David
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [3] Measurement of Retinal Blood Flow in Normal Chinese-American Subjects by Doppler Fourier-Domain Optical Coherence Tomography
    Srinivas, Sowmya
    Tan, Ou
    Wu, Shuang
    Nittala, Muneeswar Gupta
    Huang, David
    Varma, Rohit
    Sadda, SriniVas R.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (03) : 1569 - 1574
  • [4] Investigation of Retinal Blood Flow in Glaucoma Patients by Doppler Fourier-Domain Optical Coherence Tomography
    Wang, Yimin
    Zhang, Xinbo
    Tan, Ou
    Huang, David
    [J]. OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XV, 2011, 7889
  • [5] Assessment of Retinal Blood Flow in Diabetic Retinopathy Using Doppler Fourier-Domain Optical Coherence Tomography
    Srinivas, Sowmya
    Nittala, Muneeswar
    Lee, Jennifer
    Tan, Ou
    Fawzi, Amani
    Huang, David
    Sadda, Srinivas
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [6] ASSESSMENT OF RETINAL BLOOD FLOW IN DIABETIC RETINOPATHY USING DOPPLER FOURIER-DOMAIN OPTICAL COHERENCE TOMOGRAPHY
    Srinivas, Sowmya
    Tan, Ou
    Nittala, Muneeswar G.
    Wu, Jennifer L.
    Fawzi, Amani A.
    Huang, David
    Sadda, Srinivas R.
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (11): : 2001 - 2007
  • [7] Measurement of retinal blood flow in the rat by combining Doppler Fourier-domain optical coherence tomography with fundus imaging
    Werkmeister, Rene M.
    Vietauer, Martin
    Knopf, Corinna
    Fuernsinn, Clemens
    Leitgeb, Rainer A.
    Reitsamer, Herbert
    Groeschl, Martin
    Garhoefer, Gerhard
    Vilser, Walthard
    Schmetterer, Leopold
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (10)
  • [8] REPRODUCIBILITY AND REPEATABILITY OF CIRRUS AND SPECTRALIS FOURIER-DOMAIN OPTICAL COHERENCE TOMOGRAPHY OF HEALTHY AND EPIRETINAL MEMBRANE EYES
    Pinilla, Isabel
    Garcia-Martin, Elena
    Fernandez-Larripa, Sonia
    Fuentes-Broto, Lorena
    Sanchez-Cano, Ana I.
    Abecia, Emilio
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2013, 33 (07): : 1448 - 1455
  • [9] Measurement of total blood flow in the normal human retina using Doppler Fourier-domain optical coherence tomography
    Wang, Y.
    Lu, A.
    Gil-Flamer, J.
    Tan, O.
    Izatt, J. A.
    Huang, D.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (05) : 634 - 637
  • [10] Repeatability and Reproducibility of Retinal Blood Flow Measurement Using a Doppler Optical Coherence Tomography Flowmeter in Healthy Subjects
    Tani, Tomofumi
    Song, Young-Seok
    Yoshioka, Takafumi
    Omae, Tsuneaki
    Ishibazawa, Akihiro
    Akiba, Masahiro
    Yoshida, Akitoshi
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (07) : 2891 - 2898