Measurement of retinal blood flow in the rat by combining Doppler Fourier-domain optical coherence tomography with fundus imaging

被引:16
|
作者
Werkmeister, Rene M. [1 ]
Vietauer, Martin [1 ,2 ]
Knopf, Corinna [1 ]
Fuernsinn, Clemens [3 ]
Leitgeb, Rainer A. [1 ]
Reitsamer, Herbert [4 ]
Groeschl, Martin [2 ]
Garhoefer, Gerhard [5 ]
Vilser, Walthard [6 ]
Schmetterer, Leopold [1 ,5 ]
机构
[1] Med Univ Vienna, Ctr Med Phys & Biomed Engn, A-1090 Vienna, Austria
[2] Vienna Univ Technol, Inst Appl Phys, A-1040 Vienna, Austria
[3] Med Univ Vienna, Dept Internal Med 2, A-1090 Vienna, Austria
[4] Paracelsus Univ, Dept Ophthalmol, A-5020 Salzburg, Austria
[5] Med Univ Vienna, Dept Clin Pharmacol, A-1090 Vienna, Austria
[6] Imedos Syst UG, D-07751 Jena, Germany
基金
奥地利科学基金会;
关键词
retinal blood flow; animal experiments; Doppler; optical coherence tomography; DIABETIC-RETINOPATHY; OCT; ANGIOGRAPHY; VELOCITY; MECHANISMS; FLOWMETRY; HYPEROXIA; HYPEREMIA; VESSELS;
D O I
10.1117/1.JBO.19.10.106008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A wide variety of ocular diseases are associated with abnormalities in ocular circulation. As such, there is considerable interest in techniques for quantifying retinal blood flow, among which Doppler optical coherence tomography (OCT) may be the most promising. We present an approach to measure retinal blood flow in the rat using a new optical system that combines the measurement of blood flow velocities via Doppler Fourier-domain optical coherence tomography and the measurement of vessel diameters using a fundus camera-based technique. Relying on fundus images for extraction of retinal vessel diameters instead of OCT images improves the reliability of the technique. The system was operated with an 841-nm superluminescent diode and a charge-coupled device camera that could be operated at a line rate of 20 kHz. We show that the system is capable of quantifying the response of 100% oxygen breathing on the retinal blood flow. In six rats, we observed a decrease in retinal vessel diameters of 13.2% and a decrease in retinal blood velocity of 42.6%, leading to a decrease in retinal blood flow of 56.7%. Furthermore, in four rats, the response of retinal blood flow during stimulation with diffuse flicker light was assessed. Retinal vessel diameter and blood velocity increased by 3.4% and 28.1%, respectively, leading to a relative increase in blood flow of 36.2%. The presented technique shows much promise to quantify early changes in retinal blood flow during provocation with various stimuli in rodent models of ocular diseases in rats. (C) The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Investigation of Retinal Blood Flow in Glaucoma Patients by Doppler Fourier-Domain Optical Coherence Tomography
    Wang, Yimin
    Zhang, Xinbo
    Tan, Ou
    Huang, David
    [J]. OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XV, 2011, 7889
  • [2] Measurement of Retinal Blood Flow in Normal Chinese-American Subjects by Doppler Fourier-Domain Optical Coherence Tomography
    Srinivas, Sowmya
    Tan, Ou
    Wu, Shuang
    Nittala, Muneeswar Gupta
    Huang, David
    Varma, Rohit
    Sadda, SriniVas R.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (03) : 1569 - 1574
  • [3] Measurement of Retinal Blood Flow Using a Newly Developed Doppler Fourier-Domain Optical Coherence Tomography Instruments in Cats
    Nagaoka, Taiji
    Tani, Tomofumi
    Sato, Eiichi
    Yoshioka, Takafumi
    Sogawa, Kenji
    Nakabayashi, Seigo
    Yoshida, Akitoshi
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [4] In vivo retinal blood flow measurement by Fourier domain Doppler optical coherence tomography
    Wang, Yimin
    Tan, Ou
    Huang, David
    [J]. COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE XII, 2008, 6847
  • [5] Retinal blood flow measurement by circumpapillary Fourier domain Doppler optical coherence tomography
    Wang, Yimin
    Bower, Bradley A.
    Izatt, Joseph A.
    Tan, Ou
    Huang, David
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (06)
  • [6] Retinal blood flow measurement by circumpapillary Fourier domain Doppler optical coherence tomography
    University of Southern California, Doheny Eye Institute, Department of Ophthalmology, 1355 San Pablo Street, Los Angeles, CA 90033, United States
    不详
    不详
    [J]. J Biomed Opt, 2008, 6
  • [7] Assessment of Retinal Blood Flow in Diabetic Retinopathy Using Doppler Fourier-Domain Optical Coherence Tomography
    Srinivas, Sowmya
    Nittala, Muneeswar
    Lee, Jennifer
    Tan, Ou
    Fawzi, Amani
    Huang, David
    Sadda, Srinivas
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [8] ASSESSMENT OF RETINAL BLOOD FLOW IN DIABETIC RETINOPATHY USING DOPPLER FOURIER-DOMAIN OPTICAL COHERENCE TOMOGRAPHY
    Srinivas, Sowmya
    Tan, Ou
    Nittala, Muneeswar G.
    Wu, Jennifer L.
    Fawzi, Amani A.
    Huang, David
    Sadda, Srinivas R.
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (11): : 2001 - 2007
  • [9] Quantitative Analysis of Retinal Blood Flow in Normal and Glaucoma by Doppler Fourier-Domain Optical Coherence Tomography
    Srinivas, Sowmya
    Nittala, Muneeswar Gupta
    Tan, Ou
    Varma, Rohit
    Francis, Brian A.
    Greenfield, David S.
    Parrish, Richard K.
    Schuman, Joel S.
    Sadda, Srinivas R.
    Huang, David
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [10] Investigation of Retinal Blood Flow in Normal and Glaucoma Subjects by Doppler Fourier-Domain Optical Coherence Tomography
    Wang, Yimin
    Tan, Ou
    Huang, David
    [J]. OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIII, 2009, 7168