Measurement of retinal blood flow in the rat by combining Doppler Fourier-domain optical coherence tomography with fundus imaging

被引:16
|
作者
Werkmeister, Rene M. [1 ]
Vietauer, Martin [1 ,2 ]
Knopf, Corinna [1 ]
Fuernsinn, Clemens [3 ]
Leitgeb, Rainer A. [1 ]
Reitsamer, Herbert [4 ]
Groeschl, Martin [2 ]
Garhoefer, Gerhard [5 ]
Vilser, Walthard [6 ]
Schmetterer, Leopold [1 ,5 ]
机构
[1] Med Univ Vienna, Ctr Med Phys & Biomed Engn, A-1090 Vienna, Austria
[2] Vienna Univ Technol, Inst Appl Phys, A-1040 Vienna, Austria
[3] Med Univ Vienna, Dept Internal Med 2, A-1090 Vienna, Austria
[4] Paracelsus Univ, Dept Ophthalmol, A-5020 Salzburg, Austria
[5] Med Univ Vienna, Dept Clin Pharmacol, A-1090 Vienna, Austria
[6] Imedos Syst UG, D-07751 Jena, Germany
基金
奥地利科学基金会;
关键词
retinal blood flow; animal experiments; Doppler; optical coherence tomography; DIABETIC-RETINOPATHY; OCT; ANGIOGRAPHY; VELOCITY; MECHANISMS; FLOWMETRY; HYPEROXIA; HYPEREMIA; VESSELS;
D O I
10.1117/1.JBO.19.10.106008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A wide variety of ocular diseases are associated with abnormalities in ocular circulation. As such, there is considerable interest in techniques for quantifying retinal blood flow, among which Doppler optical coherence tomography (OCT) may be the most promising. We present an approach to measure retinal blood flow in the rat using a new optical system that combines the measurement of blood flow velocities via Doppler Fourier-domain optical coherence tomography and the measurement of vessel diameters using a fundus camera-based technique. Relying on fundus images for extraction of retinal vessel diameters instead of OCT images improves the reliability of the technique. The system was operated with an 841-nm superluminescent diode and a charge-coupled device camera that could be operated at a line rate of 20 kHz. We show that the system is capable of quantifying the response of 100% oxygen breathing on the retinal blood flow. In six rats, we observed a decrease in retinal vessel diameters of 13.2% and a decrease in retinal blood velocity of 42.6%, leading to a decrease in retinal blood flow of 56.7%. Furthermore, in four rats, the response of retinal blood flow during stimulation with diffuse flicker light was assessed. Retinal vessel diameter and blood velocity increased by 3.4% and 28.1%, respectively, leading to a relative increase in blood flow of 36.2%. The presented technique shows much promise to quantify early changes in retinal blood flow during provocation with various stimuli in rodent models of ocular diseases in rats. (C) The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Fourier-Domain Optical Coherence Tomography Imaging in Keratoconus A Corneal Structural Classification
    Sandali, Otman
    El Sanharawi, Mohamed
    Temstet, Cyril
    Hamiche, Taous
    Galan, Alice
    Ghouali, Wajdene
    Goemaere, Isabelle
    Basli, Elena
    Borderie, Vincent
    Laroche, Laurent
    [J]. OPHTHALMOLOGY, 2013, 120 (12) : 2403 - 2412
  • [42] Measurement of Absolute Flow Velocities by Dual-Beam Bidirectional Fourier-Domain Optical Coherence Tomography
    Werkmeister, R. M.
    Dragostinoff, N.
    Schmoll, T.
    Schmetterer, L.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [43] Evaluation of Retinal Nerve Fiber Layer Thinning With Fourier-Domain Optical Coherence Tomography
    Leung, Christopher Kai-Shun
    [J]. JAMA OPHTHALMOLOGY, 2017, 135 (04) : 337 - 338
  • [44] Glaucoma Diagnostic Performance of Retinal Blood Flow Measurement With Doppler Optical Coherence Tomography
    Abe, Tsubasa
    Yoshioka, Takafumi
    Song, Youngseok
    Tani, Tomofumi
    Kawai, Motofumi
    Omae, Tsuneaki
    Takahashi, Kengo
    Takizawa, Yoshitaka
    Ro-Mase, Tomoko
    Ishiko, Satoshi
    Minamide, Kana
    Sakai, Jun
    Akiba, Masahiro
    Hashimoto, Yohei
    Yoshida, Akitoshi
    [J]. TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (10):
  • [45] Total retinal blood flow measurement by three beam Doppler optical coherence tomography
    Haindl, Richard
    Trasischker, Wolfgang
    Wartak, Andreas
    Baumann, Bernhard
    Pircher, Michael
    Hitzenberger, Christoph K.
    [J]. BIOMEDICAL OPTICS EXPRESS, 2016, 7 (02): : 287 - 301
  • [46] Time-domain interpolation for Fourier-domain optical coherence tomography
    Zhang, Yudong
    Li, Xiqi
    Wei, Ling
    Wang, Kai
    Ding, Zhihua
    Shi, Guohua
    [J]. OPTICS LETTERS, 2009, 34 (12) : 1849 - 1851
  • [47] In vivo human retinal imaging by Fourier domain optical coherence tomography
    Wojtkowski, M
    Leitgeb, R
    Kowalczyk, A
    Bajraszewski, T
    Fercher, AF
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (03) : 457 - 463
  • [48] Characterization of coated optical fibers by Fourier-domain optical coherence tomography
    Jasapara, J
    Wielandy, S
    [J]. OPTICS LETTERS, 2005, 30 (09) : 1018 - 1020
  • [49] Detection of photoreceptor disruption by adaptive optics fundus imaging and Fourier-domain optical coherence tomography in eyes with occult macular dystrophy
    Kitaguchi, Yoshiyuki
    Kusaka, Shunji
    Yamaguchi, Tatsuo
    Mihashi, Toshifumi
    Fujikado, Takashi
    [J]. CLINICAL OPHTHALMOLOGY, 2011, 5 : 345 - 351
  • [50] Macular thickness of Chinese with fourier-domain optical coherence tomography
    Yu Weihong
    Zheng Lin
    Dai Rongping
    Zhang Zhiqiao
    Dong Fangtian
    [J]. ACTA OPHTHALMOLOGICA, 2011, 89 (01) : E104 - E105