In situ measurement of 3D contact angle in sand based on X-ray computed tomography

被引:2
|
作者
Schlueter, Steffen [1 ]
Blaser, Sebastian R. G. A. [1 ]
Benard, Pascal [2 ]
Carminati, Andrea [2 ]
机构
[1] UFZ Helmholtz Ctr Environm Res, Dept Soil Syst Sci, Theodor Lieser Str 4, D-06120 Halle, Germany
[2] Swiss Fed Inst Technol, Dept Environm Syst Sci, Inst Terr Ecosyst, Phys Soils & Terr Ecosyst, Univ Str 1, CH-8092 Zurich, Switzerland
关键词
SOIL; IMAGES;
D O I
10.1002/vzj2.20197
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Soil water repellency is traditionally expressed as contact angle (CA) and measured destructively on exposed surfaces or derived from flow behavior or measured forces. These approaches cannot map local heterogeneities in CA, which typically exist in intact soil. Here, we explore the potential and limitations of in situ measurements of three-dimensional CAs with simplified benchmark tests and in intact sand. The method is based on a protocol for the freely available OpenFOAM software and applied to segmented X-ray computed tomography (X-ray CT) data. This study scrutinizes its suitability under typical vadose zone conditions, as it was originally developed for rock studies in petroleum engineering. The assets of the method are that it allows for accurate measurement of locally varying, equilibrium contact angles and that they can be linked to pore scale features that cause them. This is demonstrated with rehydrated mucilage structures in sand and the associated change in local CAs, where they touch sand grains. In general, the image acquisition time of polychromatic X-ray CT (minutes) precludes the assessments of dynamic CAs that may equilibrate within seconds. Another limitation is that acute CAs are overestimated due to the voxel discretization of interfaces and contact lines in combination with image smoothing. The divergence arises around 60 degrees and is most severe in the limit of vanishing water repellency. In summary, the method enables the mapping of local heterogeneities of equilibrium CAs, though the absolute values should be critically assessed.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] X-ray computed tomography for 3D crystallization monitoring: A use case with paracetamol
    Clercq, Sebastien
    Vicente, Jerome
    Moulin, Philippe
    JOURNAL OF CRYSTAL GROWTH, 2024, 642
  • [42] Deep 3D reconstruction of synchrotron X-ray computed tomography for intact lungs
    Shin, Seungjoo
    Kim, Min Woo
    Jin, Kyong Hwan
    Yi, Kwang Moo
    Kohmura, Yoshiki
    Ishikawa, Tetsuya
    Je, Jung Ho
    Park, Jaesik
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [43] 3D Quantitative Mineral Characterization of Particles Using X-ray Computed Tomography
    Godinho, Jose Ricardo Assuncao
    Hassanzadeh, Ahmad
    Heinig, Thomas
    NATURAL RESOURCES RESEARCH, 2023, 32 (02) : 479 - 499
  • [44] Assessing rechargeable batteries with 3D X-ray microscopy, computed tomography, and nanotomography
    Villarraga-Gomez, Herminso
    Begun, Dana L.
    Bhattad, Pradeep
    Mo, Kai
    Rad, Mansoureh Norouzi
    White, Robin T.
    Kelly, Stephen T.
    NONDESTRUCTIVE TESTING AND EVALUATION, 2022, 37 (05) : 519 - 535
  • [45] 3D Quantitative Mineral Characterization of Particles Using X-ray Computed Tomography
    Jose Ricardo Assunção Godinho
    Ahmad Hassanzadeh
    Thomas Heinig
    Natural Resources Research, 2023, 32 : 479 - 499
  • [46] 3D characterization of walnut morphological traits using X-ray computed tomography
    Anthony Bernard
    Sherif Hamdy
    Laurence Le Corre
    Elisabeth Dirlewanger
    Fabrice Lheureux
    Plant Methods, 16
  • [47] 3D analysis of TRISO fuel compacts via X-ray computed tomography
    Kane, Joshua J.
    Marshall, Douglas W.
    Cordes, Nikolaus L.
    Chuirazzi, William C.
    Kombaiah, Boopathy
    van Rooyen, Isabella
    Stempien, John D.
    JOURNAL OF NUCLEAR MATERIALS, 2022, 565
  • [48] Deep 3D reconstruction of synchrotron X-ray computed tomography for intact lungs
    Seungjoo Shin
    Min Woo Kim
    Kyong Hwan Jin
    Kwang Moo Yi
    Yoshiki Kohmura
    Tetsuya Ishikawa
    Jung Ho Je
    Jaesik Park
    Scientific Reports, 13
  • [49] X-ray ptychographic computed tomography at 16 nm isotropic 3D resolution
    Holler, M.
    Diaz, A.
    Guizar-Sicairos, M.
    Karvinen, P.
    Farm, Elina
    Harkonen, Emma
    Ritala, Mikko
    Menzel, A.
    Raabe, J.
    Bunk, O.
    SCIENTIFIC REPORTS, 2014, 4
  • [50] X-ray ptychographic computed tomography at 16 nm isotropic 3D resolution
    M. Holler
    A. Diaz
    M. Guizar-Sicairos
    P. Karvinen
    Elina Färm
    Emma Härkönen
    Mikko Ritala
    A. Menzel
    J. Raabe
    O. Bunk
    Scientific Reports, 4