Experimental study of double-panel confined masonry walls under lateral loading

被引:12
|
作者
Belghiat, Choayb [1 ,3 ]
Messabhia, Ali [1 ]
Plassiard, Jean-Patrick [3 ]
Guenfoud, Mohamed [1 ,2 ]
Ple, Olivier [3 ]
Perrotin, Pascal [3 ]
机构
[1] Univ Larbi Tebessi, Appl Civil Engn Lab, Route Constantine, Tebessa 12002, Algeria
[2] Univ 8 May 1945 Guelma, BP 401, Guelma 24000, Algeria
[3] Univ Savoie Mt Blanc, CNRS, LOCIE, Campus Sci Savoie Technolac, F-73376 Le Bourget Du Lac, Chambery, France
关键词
Confined masonry; Uniform confinement; Toothed confinement; Wall density; Double-panel; Pushover test;
D O I
10.1016/j.jobe.2018.09.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Confined masonry structures are one of the most widely used construction systems in Algeria, in which both walls and confining elements contribute to carrying the gravity and seismic loads. Several types of confining elements are used (uniform confinements, toothed confinements), each one giving the structure a different mechanical behavior while the wall density is considered as a key safety factor for those structures. The study presented in this paper is an experimental study on two types of confinement. The study originality stems from the size of the tested samples, which included double-panel confined masonry and experimental pushover tests. First, uniform masonry walls and confinements are studied. Second, toothed masonry walls consisting of two panels of Algerian clay bricks are tested. The objectives were on one hand to study the impact of the frame/panel connection on the quasi-static behavior of the structure as well as the loading and unloading behaviors. On the other hand, to highlight the impact of using double-panel walls on resisting mechanism of confined masonry walls. Moreover, the obtained data were used for evaluating the existing analytical models to predict lateral capacities of confined masonry walls. The results indicate that the two sample-types show some similar resisting mechanisms but various capacities under progressive lateral loading, which may have consequences on the seismic resistance of the structure. A mixture of shear-flexural mechanism can be noticed when double-panel walls are used.
引用
收藏
页码:531 / 543
页数:13
相关论文
共 50 条
  • [1] Analytical and numerical study of double-panel confined masonry walls
    Belghiat, Choayb
    Plassiard, Jean-Patrick
    Messabhia, Ali
    Ple, Olivier
    Guenfoud, Mohamed
    JOURNAL OF BUILDING ENGINEERING, 2021, 39
  • [2] Experimental study of confined masonry walls under blast loading
    Codina, R.
    Ambrosini, D.
    SHOCK WAVES, 2022, 32 (03) : 261 - 272
  • [3] Experimental study of confined masonry walls under blast loading
    R. Codina
    D. Ambrosini
    Shock Waves, 2022, 32 : 261 - 272
  • [4] Experimental assessment of confined masonry walls retrofitted with SRG under lateral cyclic loads
    Yacila, Jhair
    Salsavilca, Jhoselyn
    Tarque, Nicola
    Camata, Guido
    ENGINEERING STRUCTURES, 2019, 199
  • [5] Shearing of infill masonry walls under lateral and vertical loading
    Brodsky, Alex
    Yankelevsky, David Z.
    Rabinovitch, Oded
    JOURNAL OF BUILDING ENGINEERING, 2021, 38 (38):
  • [6] An Experimental Study of Confined Masonry Walls with Varying Aspect Ratios
    Perez Gavilan, J. J.
    Flores, L. E.
    Alcocer, S. M.
    EARTHQUAKE SPECTRA, 2015, 31 (02) : 945 - 968
  • [7] Response of slender reinforced masonry shear walls with flanged boundary elements under in-plane lateral loading: An experimental study
    Robazza, B. R.
    Yang, T. Y.
    Brzev, S.
    Elwood, K. J.
    Anderson, D. L.
    McEwen, W.
    ENGINEERING STRUCTURES, 2019, 190 : 389 - 409
  • [8] Experimental investigation of confined masonry infill walls
    Leal G, J. M.
    Perez Gavilan, J. J.
    Castorena G, J. H.
    Velazquez D, J., I
    BRICK AND BLOCK MASONRY: TRENDS, INNOVATIONS AND CHALLENGES, 2016, : 2319 - 2326
  • [9] Experimental performance of reinforced double H-block masonry shear walls under cyclic loading
    Gao Ma
    Liang Huang
    Libo Yan
    Bohumil Kasal
    Liang Chen
    Chengzhi Tao
    Materials and Structures, 2017, 50
  • [10] Experimental performance of reinforced double H-block masonry shear walls under cyclic loading
    Ma, Gao
    Huang, Liang
    Yan, Libo
    Kasal, Bohumil
    Chen, Liang
    Tao, Chengzhi
    MATERIALS AND STRUCTURES, 2017, 50 (01)