Handling interferences in 89Sr and 90Sr measurements of reactor coolant water: A method based on strontium separation chemistry

被引:13
|
作者
Holmgren, S. [1 ]
Tovedal, A. [1 ]
Jonsson, S. [1 ]
Nygren, U. [1 ]
Rameback, H. [1 ,2 ]
机构
[1] Swedish Def Res Agcy, SE-90182 Umea, Sweden
[2] Chalmers Univ Technol, Dept Chem & Biol Engn, SE-41296 Gothenburg, Sweden
关键词
Separation; Sr-89; Sr-90; Sr-85; Reactor coolant water; Interferences; RAPID-DETERMINATION; EXTRACTION CHROMATOGRAPHY; RADIOSTRONTIUM;
D O I
10.1016/j.apradiso.2014.03.022
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Measurements for determining the activity of Sr-89 and Sr-90 in reactor coolant water are associated with limitations due to interferences from radionuclides with similar chemical properties and beta(-)-energies. From a measurement bias point-of-view these interferences would result mainly in an overestimated activity concentration of Sr-90. In order to address the interference problem, a common and well-known method was used in order to show the need for sufficient decontamination. An improvement was achieved by taking the sample through two initial strontium separations in order to increase the decontamination factor. This method determines the activity concentration of Sr-89 and Sr-90, via its daughter nuclide Y-90, by Cherenkov counting. This work is primarily based on theoretical calculations of strontium-, yttrium- and other potential interfering radionuclide ratios after instant fission. The work done to confirm the theoretical calculations were carried through on spiked strontium standard solutions and fresh reactor coolant water. The reactor coolant water was known to contain interferences at a composition resembling that of instant fission. The detection limit for double separation was calculated to 0.17 Bq/kg for Sr-90 and 0.38 Bq/kg for Sr-89. When using methods that solely rely on strontium resins, this paper shows that the decontamination factor (DF) is significantly higher when using double separation than that of a single separation. The paper also shows that the DF of an initial double strontium separation is as effective when it comes to removing high ratio interferences as separations done with both Sr- and Ln-resin (EiChrom Technologies, Inc., 2003; Tovedal at at, 2009b). However, 'old' samples, where e.g. Ba-140 and Sr-89 has decayed, does not benefit from double separation. Furthermore, samples with low ratios of interfering radionuclides does not benefit from using this method either, seeing as this is a more time consuming method due to the double separations. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:94 / 101
页数:8
相关论文
共 50 条
  • [41] A rapid method for simultaneously determining activity of 89Sr and 90Sr in a non-equilibrated 90Sr/90Y system without Cerenkov counting (vol 333, pg 841, 2024)
    Wei, Cong
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2024, : 2555 - 2555
  • [42] Rapid column extraction method for actinides and 89/90Sr in water samples
    Maxwell, SL
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2006, 267 (03) : 537 - 543
  • [43] Rapid column extraction method for actinides and 89/90Sr in water samples
    S. L. Maxwell III
    Journal of Radioanalytical and Nuclear Chemistry, 2006, 267 : 537 - 543
  • [44] Determination of 89Sr and 90Sr from low- and intermediate-level radioactive liquid waste
    Vincze, A
    Solymosi, J
    Ormai, P
    Volent, G
    NUCLEAR PHYSICAL METHODS IN RADIOECOLOGICAL INVESTIGATIONS OF NUCLEAR TEST SITES, 2000, 31 : 145 - 150
  • [45] 90Sr and 89Sr in seawater off Japan as a consequence of the Fukushima Dai-ichi nuclear accident
    Casacuberta, N.
    Masque, P.
    Garcia-Orellana, J.
    Garcia-Tenorio, R.
    Buesseler, K. O.
    BIOGEOSCIENCES, 2013, 10 (06) : 3649 - 3659
  • [46] Rapid method to determine 89/90Sr in steel samples
    Sherrod L. Maxwell
    Brian Culligan
    Jay B. Hutchison
    Robin C. Utsey
    Ralf Sudowe
    Daniel R. McAlister
    Journal of Radioanalytical and Nuclear Chemistry, 2017, 314 : 439 - 450
  • [47] Evaluation of different methods for measuring 89Sr and 90Sr: Measurement uncertainty for the different methods as a function of the activity ratio
    Rondahl, Stina Holmgren
    Rameback, Henrik
    APPLIED RADIATION AND ISOTOPES, 2018, 140 : 87 - 95
  • [48] Rapid method to determine 89/90Sr in steel samples
    Maxwell, Sherrod L.
    Culligan, Brian
    Hutchison, Jay B.
    Utsey, Robin C.
    Sudowe, Ralf
    McAlister, Daniel R.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2017, 314 (01) : 439 - 450
  • [49] Effect of 87Sr hyperfine structure on the isotope selective excitation of 89Sr and 90Sr isotopes in collinear resonance ionization spectroscopy
    Sankari, M
    Suryanarayana, MV
    JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 2002, 35 (04) : 983 - 995
  • [50] Methodology for determination of 89Sr and 90Sr in radiological emergency: I. Scenario dependent evaluation of potentially interfering radionuclides
    Tovedal, Annika
    Nygren, Ulrika
    Rameback, Henrik
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 282 (02) : 455 - 459