Handling interferences in 89Sr and 90Sr measurements of reactor coolant water: A method based on strontium separation chemistry

被引:13
|
作者
Holmgren, S. [1 ]
Tovedal, A. [1 ]
Jonsson, S. [1 ]
Nygren, U. [1 ]
Rameback, H. [1 ,2 ]
机构
[1] Swedish Def Res Agcy, SE-90182 Umea, Sweden
[2] Chalmers Univ Technol, Dept Chem & Biol Engn, SE-41296 Gothenburg, Sweden
关键词
Separation; Sr-89; Sr-90; Sr-85; Reactor coolant water; Interferences; RAPID-DETERMINATION; EXTRACTION CHROMATOGRAPHY; RADIOSTRONTIUM;
D O I
10.1016/j.apradiso.2014.03.022
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Measurements for determining the activity of Sr-89 and Sr-90 in reactor coolant water are associated with limitations due to interferences from radionuclides with similar chemical properties and beta(-)-energies. From a measurement bias point-of-view these interferences would result mainly in an overestimated activity concentration of Sr-90. In order to address the interference problem, a common and well-known method was used in order to show the need for sufficient decontamination. An improvement was achieved by taking the sample through two initial strontium separations in order to increase the decontamination factor. This method determines the activity concentration of Sr-89 and Sr-90, via its daughter nuclide Y-90, by Cherenkov counting. This work is primarily based on theoretical calculations of strontium-, yttrium- and other potential interfering radionuclide ratios after instant fission. The work done to confirm the theoretical calculations were carried through on spiked strontium standard solutions and fresh reactor coolant water. The reactor coolant water was known to contain interferences at a composition resembling that of instant fission. The detection limit for double separation was calculated to 0.17 Bq/kg for Sr-90 and 0.38 Bq/kg for Sr-89. When using methods that solely rely on strontium resins, this paper shows that the decontamination factor (DF) is significantly higher when using double separation than that of a single separation. The paper also shows that the DF of an initial double strontium separation is as effective when it comes to removing high ratio interferences as separations done with both Sr- and Ln-resin (EiChrom Technologies, Inc., 2003; Tovedal at at, 2009b). However, 'old' samples, where e.g. Ba-140 and Sr-89 has decayed, does not benefit from double separation. Furthermore, samples with low ratios of interfering radionuclides does not benefit from using this method either, seeing as this is a more time consuming method due to the double separations. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:94 / 101
页数:8
相关论文
共 50 条
  • [31] A rapid method for simultaneously determining activity of 89Sr and 90Sr in a non-equilibrated 90Sr/90Y system without Cerenkov counting
    Wei, Cong
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2024, 333 (02) : 841 - 845
  • [32] 89Sr样品中90Sr含量的简便测定方法
    张蕾
    何蔚瑜
    沈德群
    曹本红
    核技术, 1999, (08) : 500 - 503
  • [33] Simultaneous measurement of 89Sr and 90Sr in aqueous samples by liquid scintillation counting using the spectrum unfolding method
    Hong, KH
    Cho, YH
    Lee, MH
    Choi, GS
    Lee, CW
    APPLIED RADIATION AND ISOTOPES, 2001, 54 (02) : 299 - 305
  • [34] Calculations of all Reactions for n+88Sr,89Sr and 90Sr in En=0.001~20 MeV
    Cai Chonghai (Department of Physics
    中国核科技报告, 1998, (S4) : 53 - 63
  • [35] 进出口食品中89Sr和90Sr的快速检测
    尚迪
    于成龙
    马思政
    杜瑶芳
    陆地
    检验检疫学刊, 2017, 27 (03) : 10 - 13
  • [36] Structure of high-spin states in 89Sr and 90Sr -: art. no. 064315
    Stefanova, EA
    Schwengner, R
    Rainovski, G
    Schilling, KD
    Wagner, A
    Dönau, F
    Galindo, E
    Jungclaus, A
    Lieb, KP
    Thelen, O
    Eberth, J
    Napoli, DR
    Ur, CA
    de Angelis, G
    Axiotis, M
    Gadea, A
    Marginean, N
    Martinez, T
    Kröll, T
    Kutsarova, T
    PHYSICAL REVIEW C, 2001, 63 (06):
  • [37] Estimation of Temporal Variation of Discharged Inventory of Radioactive Strontium 90Sr (89Sr) from Port of Fukushima Daiichi Nuclear Power Plant
    Machida M.
    Iwata A.
    Yamada S.
    Otosaka S.
    Kobayashi T.
    Funasaka H.
    Morita T.
    Transactions of the Atomic Energy Society of Japan, 2023, 22 (04) : 119 - 139
  • [38] Rapid determination of 89Sr and 90Sr in radioactive waste using Sr extraction disk and beta-ray spectrometer
    Kameo, Y.
    Katayama, A.
    Fujiwara, A.
    Haraga, T.
    Nakashima, M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 274 (01) : 71 - 78
  • [39] Rapid determination of 89Sr and 90Sr in radioactive waste using Sr extraction disk and beta-ray spectrometer
    Y. Kameo
    A. Katayama
    A. Fujiwara
    T. Haraga
    M. Nakashima
    Journal of Radioanalytical and Nuclear Chemistry, 2007, 274 : 71 - 78
  • [40] The evaluation of transmutation of hazardous nuclear waste of 90Sr, into valuable nuclear medicine of 89Sr by ultraintense lasers
    Sadighi, S. K.
    Sadighi-Bonabi, R.
    LASER AND PARTICLE BEAMS, 2010, 28 (02) : 269 - 276