Dosimetric verification of a commercial 3D treatment planning system for conformal radiotherapy with a dynamic multileaf collimator

被引:3
|
作者
Pignoli, E
Serretiello, S
Somigliana, A
Zonca, G
Pellegrini, R
Mongioj, V
Marchesini, R
机构
[1] Ist Nazl Studio & Cura Tumori, Med Phys Unit, I-20133 Milan, Italy
[2] 3D Line Int SRL, I-20131 Milan, Italy
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2000年 / 45卷 / 08期
关键词
D O I
10.1088/0031-9155/45/8/401
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The dosimetric accuracy of a 3D treatment planning system (TPS) for conformal radiotherapy with a computer-assisted dynamic multileaf collimator (DMLC) was evaluated. The DMLC and the TPS have been developed for clinical applications where dynamic fields not greater than 10 x 10 cm(2) and multiple non-coplanar arcs are required. Dosimetric verifications were performed by simulating conformal treatments of irregularly shaped targets using several arcs of irradiation with 6 MV x-rays and a spherical-shaped, tissue-simulating phantom. The accuracy of the delivered dose at the isocentre was verified using an ionization chamber placed in the centre of the phantom. Isodose distributions in the axial and sagittal planes passing through the centre of the phantom were measured using double-layer radiochromic films. Measured dose at the isocentre as well as isodose distributions were compared to those calculated by the TPS. The maximum percentage difference between measured and prescribed dose was less than 2.5% for all the simulated treatment plans. The mean (ISI) displacement between measured and calculated isodoses was, in the axial planes, 1.0+/-0.6 mm, 1.2+/-0.7 mm and 1.5+/-1.1 mm for 80%, 50% and 20% isodose curves, respectively, whereas in the sagittal planes it was 2.0+/-1.2 mm and 2.2+/-2 mm For 80% and 50% isodose curves, respectively. The results indicate that the accuracy of the 3D treatment planning system used with the DMLC is reasonably acceptable in clinical applications which require treatments with several non-coplanar arcs and small dynamic fields.
引用
收藏
页码:N77 / N84
页数:8
相关论文
共 50 条
  • [1] Dosimetric Verification of Modulated Electron Radiotherapy Delivery Using Photon Multileaf Collimator
    Jin, L.
    Ma, C.
    Eldib, A.
    Fan, J.
    Chi, Z.
    Li, J.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [2] Optimization of multileaf collimator settings for radiotherapy treatment planning
    van Dalen, S
    Keijzer, M
    Huizenga, H
    Storchi, PRM
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (12): : 3615 - 3625
  • [3] Dosimetric verification of a commercial inverse treatment planning system
    Lei, X
    Curran, B
    Hill, R
    Holmes, T
    Ma, LJ
    Forster, KM
    Boyer, AL
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (02): : 463 - 478
  • [4] Dosimetric verification of clinical radiotherapy treatment planning system
    Kolarevic, Goran
    Jaros, Drazan
    Marosevic, Goran
    Ignjatic, Dejan
    Mirjanic, Dragoljub
    [J]. VOJNOSANITETSKI PREGLED, 2022, 79 (02) : 115 - 124
  • [5] Dosimetric verification of a dedicated 3D treatment planning system for episcleral plaque therapy
    Knutsen, S
    Hafslund, R
    Monge, OR
    Valen, H
    Muren, LP
    Rekstad, BL
    Krohn, J
    Dahl, O
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (04): : 1159 - 1166
  • [6] Dosimetric verification of modulated electron radiotherapy delivered using a photon multileaf collimator for intact breasts
    Jin, L.
    Ma, C-M
    Fan, J.
    Eldib, A.
    Price, R. A.
    Chen, L.
    Wang, L.
    Chi, Z.
    Xu, Q.
    Sherif, M.
    Li, J. S.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (21): : 6009 - 6025
  • [7] Technical note: evaluation of dosimetric performance in a commercial 3D treatment planning system
    Sandilos, P
    Seferlis, S
    Antypas, C
    Karaiskos, P
    Dardoufas, C
    Vlahos, L
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (934): : 899 - 905
  • [8] Dosimetric comparison of different multileaf collimator leaves in treatment planning of intensity-modulated radiotherapy for cervical cancer
    Wang, Shichao
    Ai, Ping
    Xie, Li
    Xu, Qingfeng
    Bai, Sen
    Lu, You
    Li, Ping
    Chen, Nianyong
    [J]. MEDICAL DOSIMETRY, 2013, 38 (04) : 454 - 459
  • [9] Dosimetric verification of IMRT and 3D conformal treatment delivery using EPID
    Nasseri, S.
    Bahreyni, M. H.
    Momennezhad, M.
    Gholamhosseinian, H.
    Shahedi, F.
    Hashemi, S. M.
    Mohammadi, M.
    [J]. APPLIED RADIATION AND ISOTOPES, 2022, 182
  • [10] Verification MU Calculation for Conformal Radiotherapy with Multileaf Collimator Using Report AAPM TG 114
    Adrada, A.
    Tello, Z.
    Medina, L.
    Garrigo, E.
    Venencia, D.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 304 - 304