Nonimaging light concentrators for photomultiplier tubes with nonuniform response of the photocathode

被引:0
|
作者
Radu, AA
Angelescu, T
机构
[1] Inst Space Sci, RO-76900 Bucharest, Romania
[2] Univ Bucharest, Dept Phys, RO-76900 Bucharest, Romania
来源
关键词
light concentrators; photomultiplier tubes;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The relative efficiency of the photocathode of a photomultiplier tube may not be uniform over its entire diameter. A special kind of concentrator should be designed in order to send more light onto the area of the photocathode that has a higher efficiency. A design method for obtaining such a concentrator is described and the two new concentrators obtained are analyzed by ray-tracing. The capacity of the classic compound parabolic concentrator to direct more light on the areas of higher efficiency is also analyzed and the results are compared to those of the two new concentrators proposed. The total efficiency of light conversion is evaluated for the new designs proposed and the classic CPC in the case of a Hamamatsu R-7056 photomultiplier tube to be used by the VERITAS project [1].
引用
收藏
页码:183 / 190
页数:8
相关论文
共 50 条
  • [41] Improved time response for large area microchannel plate photomultiplier tubes in fusion diagnostics
    Milnes, J. S.
    Horsfield, C. J.
    Conneely, T. M.
    Howorth, J.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [42] Investigation and compensation of the nonlinear response in photomultiplier tubes for quantitative single-shot measurements
    Knappe, C.
    Linden, J.
    Abou Nada, F.
    Richter, M.
    Alden, M.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (03):
  • [44] THE APPLICATION OF (RCA 1P 28)-PHOTOMULTIPLIER TUBES TO THE DETECTION OF WEAK LIGHT INTENSITIES
    BOESCHOTEN, F
    MILATZ, JMW
    SMIT, C
    [J]. PHYSICA, 1954, 20 (02): : 139 - 156
  • [45] Detection of the VUV liquid argon scintillation light by means of glass-window photomultiplier tubes
    Benetti, P
    Montanari, C
    Raselli, GL
    Rossella, M
    Vignoli, C
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 89 - 92
  • [46] Single-photon counting at 950-1300 nm: using InGaAsP photocathode-GaAs avalanche diode hybrid photomultiplier tubes
    Sun, Xiaoli
    Krainak, Michael A.
    Hasselbrack, William E.
    Rue, Ross A. La
    Sykora, Derek F.
    [J]. JOURNAL OF MODERN OPTICS, 2009, 56 (2-3) : 284 - 295
  • [47] The photomultiplier tubes in the light sensor of an orbital detector for studying the fluorescent radiation of extensive air showers
    G. K. Garipov
    B. A. Khrenov
    B. K. Lubsandorzhiev
    S. A. Belyanchenko
    V. A. Smolitskiy
    U. Salazar
    E. Fokitis
    [J]. Instruments and Experimental Techniques, 2005, 48 : 92 - 95
  • [48] Low temperature performance of photomultiplier tubes illuminated in pulsed mode by visible and vacuum ultraviolet light
    Araujo, HM
    Chepel, VY
    Lopes, MI
    Marques, RF
    Policarpo, AJPL
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (01): : 34 - 40
  • [49] Dynamic Range Study of Microchannel Plate Photomultiplier Tubes under Visible Light Pulse Input
    Wei Jianan
    Liu Hulin
    Chen Ping
    Li Yang
    Li Kuinian
    Wei Yonglin
    He Luanxuan
    Zhao Xinnan
    Sai Xiaofeng
    Liu Deng
    Tian Jinshou
    Zhao Wei
    [J]. ACTA PHOTONICA SINICA, 2024, 53 (02)
  • [50] The photomultiplier tubes in the light sensor of an orbital detector for studying the fluorescent radiation of extensive air showers
    Garipov, GK
    Khrenov, BA
    Lubsandorzhiev, BK
    Belyanchenko, SA
    Smolitskiy, VA
    Salazar, U
    Fokitis, E
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2005, 48 (01) : 92 - 95