Immunomagnetic reduction assay using high-Tc superconducting-quantum-interference-device-based magnetosusceptometry

被引:27
|
作者
Chieh, J. J. [1 ]
Yang, Shieh-Yueh [1 ,2 ]
Horng, Herng-Er [1 ]
Yu, C. Y. [1 ]
Lee, C. L. [1 ,2 ]
Wu, H. L. [3 ]
Hong, Chin-Yih [4 ]
Yang, Hong-Chang [5 ]
机构
[1] Natl Taiwan Normal Univ, Inst Electroopt Sci & Technol, Taipei 116, Taiwan
[2] MagQu Co Ltd, Sindian City 231, Taipei County, Taiwan
[3] Natl Cheng Kung Univ, Dept Biochem & Mol Biol, Tainan 701, Taiwan
[4] Natl Chung Hsing Univ, Grad Inst Biomed Engn, Taichung 402, Taiwan
[5] Natl Taiwan Univ, Dept Phys, Taipei 106, Taiwan
关键词
MAGNETIC NANOPARTICLES; SQUID; IMMUNOASSAY;
D O I
10.1063/1.3340861
中图分类号
O59 [应用物理学];
学科分类号
摘要
Via immunomagnetic reduction assay, biomolecules can be quantitatively detected with aid of biofunctionalized magnetic nanoparticles, which are used as labeling markers for specific biomolecules. To achieve ultra-high sensitivity in detecting biomolecules, superconducting quantum interference device (SQUID) is a promising candidate to act as a sensor to the magnetic signal related to the concentration of detected biomolecules. In the past, we developed a single channel SQUID-based magnetosusceptometry. In order to increase the detection through-put, multichannel SQUID-based magnetosusceptometry is developed. In this work, the design and working principle of four-channel SQUID-based magnetosusceptometry are introduced. Using utilizing scanning technology, four samples can be simultaneously logged into the SQUID-based magnetosusceptometry. Notably, only single SQUID magnetometer is used in the magnetosusceptometry. The precision and sensitivity in detecting biomolecules using the four-channel SQUID-based magnetosusceptometry are investigated. (C) 2010 American Institute of Physics. [doi:10.1063/1.3340861]
引用
收藏
页数:5
相关论文
共 50 条
  • [21] DC SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE UTILIZING THE HIGH-TC STEP-EDGE JUNCTION
    ENPUKU, K
    UDOMOTO, J
    KISU, T
    ERAMI, A
    KUROMIZU, Y
    YOSHIDA, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 1991, 30 (6B): : L1121 - L1124
  • [22] Characterization of tumors using high-Tc superconducting quantum interference device-detected nuclear magnetic resonance and imaging
    Liao, Shu-Hsien
    Huang, Kai-Wen
    Yang, Hong-Chang
    Yen, Chang-Te
    Chen, M. J.
    Chen, Hsin-Hsien
    Horng, Herng-Er
    Yang, Shieh Yueh
    APPLIED PHYSICS LETTERS, 2010, 97 (26)
  • [23] Nondestructive detection of flaw in carbon-fiber-reinforced plastics using high-Tc superconducting quantum interference device
    Kasai, N
    Suzuki, D
    Hatsukade, Y
    Koyanagi, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2000, 39 (3A): : 1399 - 1404
  • [24] Nondestructive detection of flaw in carbon-fiber-reinforced plastics using high-Tc superconducting quantum interference device
    Kasai, Naoko
    Suzuki, Daisuke
    Hatsukade, Yoshimi
    Koyanagi, Masao
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2000, 39 (3 A): : 1399 - 1404
  • [25] Properties of a flux dam inserted in the pickup coil of a high-Tc superconducting quantum interference device magnetometer
    Enpuku, K
    Nakahodo, A
    Hotta, M
    Hijiya, S
    Tokimizu, D
    Kuroda, D
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2001, 40 (6A): : 4013 - 4018
  • [26] Inductance-dependent characteristics of high-Tc dc-superconducting quantum interference device amplifiers
    Mitchell, EE
    Tilbrook, DL
    Foley, CP
    MacFarlane, JC
    APPLIED PHYSICS LETTERS, 2002, 81 (07) : 1282 - 1284
  • [27] Note: A hand-held high-Tc superconducting quantum interference device operating without shielding
    He, D. F.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (02):
  • [28] Characteristics of directly-coupled high-Tc superconducting quantum interference device magnetometers for multichannel applications
    Kwon, H
    Kim, IS
    Lee, YH
    Kim, JM
    Park, YK
    Park, JC
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1998, 37 (02): : 496 - 499
  • [29] Low-field magnetic resonance imaging with a high-Tc dc superconducting quantum interference device
    Schlenga, K
    McDermott, R
    Clarke, J
    de Souza, RE
    Wong-Foy, A
    Pines, A
    APPLIED PHYSICS LETTERS, 1999, 75 (23) : 3695 - 3697